Description
• Data reads/writes are easily performed by simply setting parameters in the machine automation controller memory area.
• Simple device configuration, in comparison with serial communication, coupled with high-speed data processing.
• Communication programs can be easily built using the ladder program function blocks “Sysmac Library RFID Communications Library (SYSMAC-XR019)”.
Note: Refer to the V680 series catalog (Q266) and V680 series data sheet (Q267) for more information on RFID system
V680 series system configurations.
Refer to the corresponding manual of each controller for more information on controller specifications.
Applicable standards
Refer to ask your OMRON representative for the most recent applicable standards for each model.
RFID Units
| RFID Units | Appearance | Product name | Amplifier/Antenna | Number of Units connected |
Model |
|---|---|---|---|---|---|
| NX-series RFID Units |
![]() |
RFID Units | V680 series | 1 | NX-V680C1 |
![]() |
2 | NX-V680C2 |
General Specifications
| Item | Specifications | |
|---|---|---|
| Enclosure | Mounted in a panel | |
| Grounding Methods | Ground to less than 100 Ω | |
| Operating environment |
Ambient operating temperature |
0 to 55°C |
| Ambient operating humidity |
10 to 95% (with no condensation or icing) | |
| Atmosphere | Must be free from corrosive gases. | |
| Ambient storage temperature |
-25 to 70°C (with no condensation or icing) | |
| Altitude | 2,000 m max. | |
| Pollution degree | 2 or less: Conforms to JIS B3502 and IEC 61131-2 | |
| Noise immunity | 2 kV on power supply line (Conforms to IEC61000-4-4.) | |
| Overvoltage category | Category II: Conforms to JIS B3502 and IEC 61131-2 | |
| EMC immunity level | Zone B | |
| Vibration resistance | Conforms to IEC 60068-2-6. 5 to 8.4 Hz with amplitude of 3.5 mm, 8.4 to 150 Hz, acceleration of 9.8 m/s2 100 min each in X, Y, and Z directions (10 sweeps of 10 min each = 100 min total) |
|
| Shock resistance | Conforms to IEC 60068-2-27, 147 m/s2, 3 times each in X, Y, and Z directions | |
| Applicable standards | cULus: Listed (UL61010-2-201), ANSI/ISA12.12.01, EU: EN61131-2, RCM, KC: KC Registration, EAC |
|
Functions
This section describes the functions provided in an RFID Unit.
| Function name | Description |
|---|---|
| RF Communications option function | This function switches the operation sequence during communications with an RF Tag. |
| Communications command function | This function reads or writes the memory for a RF Tag on the antenna communications area. |
| Write protection function | This function prevents the loss of data due to overwriting by specifying the areas in which it is not possible to write to an RF Tag. |
| RF Tag service life detection function | This function records the number of times data is rewritten to an RF Tag, and determines the maximum rewrite count. |
| RF Tag memory error detection function | This function detects an error during reading by performing CRC calculation for the memory of an RF Tag. |
| RF Tag memory error correction function | This function detects an error during reading by performing ECC calculation for the memory of an RF Tag, and corrects the error to an appropriate value. |
| Test command function | This function checks the margin in communications with an RF Tag, and measures the surrounding noise. |
Individual Specifications
NX-V680C1
| Unit name | One-channel RFID Unit | Model | NX-V680C1 |
|---|---|---|---|
| Number of antennas connected |
1 | External connection terminal |
FG terminal block (1 terminal) |
| I/O refreshing method |
Free-Run Refreshing | ||
| Indicators | TS indicator, RF indicator, NORM indicator, and ERR indicator ![]() |
Communications protocol |
ISO/IEC18000-3 (15693) |
| Connectable Antennas |
V680-series Antenna with Separate Amplifier: V680-HS[][] Antenna with Built-in Amplifier: V680-H01-V2 |
||
| Applicable RF Tags | V680S-series RF or V680-series RF Tags |
||
| RF Tag reading/ writing size |
8,192 bytes max. | ||
| Divided data size | 16 to 128 bytes | ||
| Backup function | Supported. | ||
| Dimensions | 30 mm (W) x 100 mm (H) x 71 mm (D) |
Isolation method | Digital isolator isolation |
| Insulation resistance |
20 MΩ min. between isolated circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits for 1 minute with a leakage current of 5 mA max. |
| I/O power supply method |
Supplied from the NX bus | Current consumption from I/O power supply |
• V680-H01-V2 connection 250 mA max. • V680-HA63[] connection 210 mA max. |
| NX Unit power consumption |
• Connected to a CPU Unit 1.00 W max. • Connected to Communications Coupler Unit 0.90 W max. |
Weight | 120 g max. |
| Installation orientation and restrictions |
Installation orientation: • Connected to a CPU Unit Possible in upright installation. • Connected to a Communications Coupler Unit Possible in 6 orientations Restrictions: No restrictions |
||
NX-V680C2
| Unit name | Two-channels RFID Unit | Model | NX-V680C2 |
|---|---|---|---|
| Number of antennas connected |
2 | External connection terminal |
FG terminal block (1 terminal) |
| I/O refreshing method |
Free-Run Refreshing | ||
| Indicators | [TS] LED, [RF] LED, [NORM] LED, [ERR] LED TS indicator, RF indicator, |
Communications protocol |
ISO/IEC18000-3 (15693) |
| Connectable Antennas |
V680-series Antenna with Separate Amplifier: V680-HS[][] |
||
| Applicable RF Tags | V680S-series RF or V680-series RF Tags |
||
| RF Tag reading/ writing size |
8,192 bytes max. | ||
| Divided data size | 16 to 128 bytes | ||
| Backup function | Supported. | ||
| Dimensions | 30 mm (W) x 100 mm (H) x 71 mm (D) |
Isolation method | Digital isolator isolation |
| Insulation resistance |
20 MΩ min. between isolated circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits for 1 minute with a leakage current of 5 mA max. |
| I/O power supply method |
Supplied from the NX bus. | Current consumption from I/O power supply |
V680-HA63[] connection 380 mA max |
| NX Unit power consumption |
• Connected to a CPU Unit 1.00 W max. • Connected to Communications Coupler Unit 0.90 W max. |
Weight | 130 g max. |
| Installation orientation and restrictions |
Installation orientation: • Connected to a CPU Unit Possible in upright installation. • Connected to a Communications Coupler Unit Possible in 6 orientations Restrictions: No restrictions |
||
Version Information
Connected to a CPU Unit
Refer to the user’s manual for the CPU Unit for the models of CPU Unit to which RFID Units can be connected.
| NX Units | Corresponding unit versions/versions | ||
|---|---|---|---|
| Model | Units Versions | CPU Units | Sysmac Studio |
| NX-V680C1 | Ver. 1.0 | Version 1.13 or higher | Version 1.25 or higher |
| NX-V680C2 | |||
Connected to an EtherCAT Coupler Unit
| NX Unit | Corresponding unit versions/versions | |||
|---|---|---|---|---|
| Model | Unit Version | EtherCAT Couplers Units |
CPU Unit or Industrial PC |
Sysmac Studio |
| NX-V680C1 | Ver. 1.0 | 1.0 or later * | 1.05 or higher | Version 1.25 or higher |
| NX-V680C2 | ||||
* When connecting with other manufacturer’s master, use the EtherCAT Coupler Unit with unit version Ver.1.5 or later.
Connected to an EtherNet/IP Coupler Unit
| NX Unit | Corresponding unit versions/versions | ||||||
|---|---|---|---|---|---|---|---|
| Model | Unit Version |
Use with an NJ/NX/NY-series Controller *1 |
Use with an CS/CJ/CP-series PLC *2 |
||||
| EtherNet/IP Coupler Unit |
CPU Unit or Industrial PC |
Sysmac Studio |
EtherNet/IP Coupler Unit |
Sysmac Studio |
NX-IO Configurator |
||
| NX-V680C1 | Ver. 1.0 | Version 1.2 or later |
Version 1.14 or later |
Version 1.25 or higher |
Version 1.2 or later |
Version 1.25 or higher |
Version 1.13 or later |
| NX-V680C2 | |||||||
EtherNet/IP Coupler Units.
*2. Refer to the user’s manual of the EtherNet/IP Coupler Unit for the unit versions of CPU Units and EtherNet/IP Units
corresponding to EtherNet/ IP Coupler Units.
(Unit: mm)
NX-V680C1 (One-channel)

NX-V680C2 (Two-channels)






![NX102-[][][][]](https://al-tet-onlinesales.adbridgessolution.com/wp-content/uploads/2019/01/NX102-.jpg)

![NX-EC0[][][]](https://al-tet-onlinesales.adbridgessolution.com/wp-content/uploads/2019/01/NX-EC0.jpg)
![NX-PG0[][][]](https://al-tet-onlinesales.adbridgessolution.com/wp-content/uploads/2019/01/NX-PG0.jpg)









Reviews