NX-ECS[][][]

More precise timing control by synchronizing the position data with the EtherCAT® Distributed Clock

Categories: , ,

Description

• Open collector output type and line driver output type Incremental Encoders can be connected

• High-speed remote I/O control with communications cycle as fast as 125 μs*1

• Free-run refreshing, synchronous I/O refreshing, or task period prioritized refreshing*2 with the NX1P2 CPU Unit or EtherCAT Coupler Unit

• The MC Function Modules of the NJ/NX/NY5 Controllers allows the encoder to be used as a motion axis

• Latching (1 internal signal and 2 input signals from external devices)

• Pulse Period Measurement

• 32 bit counters (80000000 to 7FFFFFFF HEX)

• Maximum counting rate: 4 MHz (Line receiver: 4 MHz, Open collector: 500 kHz)

• Time Stamping

• Maximum and minimum counter value setting

• Connect to the CJ PLC using the EtherNet/IPTM bus coupler

*1. When using the NX-EC01[][] together with the NX701-[][][][] and NX-ECC203.
*2. Task Period Prioritized refreshing is available when the NX-ECC203 is used together.

Sysmac is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products.
EtherCAT® is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany. EtherNet/IP™ is a trademark of ODVA.
Other company names and product names in this document are the trademarks or registered trademarks of their respective companies.

 

Applicable standards

Refer to the OMRON website (www.ia.omron.com) or ask your OMRON representative for the most recent applicable standards for each model.

Position Interface: Incremental Encoder Input Units

Product
name
Specification Model
Number
of
channels
External
inputs
Maximum
response
frequency
I/O
refreshing
method
*
Number
of I/O
entry
mappings
Remarks
Incremental
Encoder
Input
Unit
3190_lu_1_1
1
(NPN)
3
(NPN)
500 kHz • Free-Run
refreshing
• Synchro-
nous I/O
refreshing
• Task
period
prioritized
refreshing
1/1 24-V
voltage
input
NX-EC0112
1
(PNP)
3
(PNP)
NX-EC0122
1 3
(NPN)
4 MHz Line
receiver
input
NX-EC0132
3
(PNP)
NX-EC0142
2
(NPN)
None 500 kHz 2/2 24-V
voltage
input
NX-EC0212
2
(PNP)
NX-EC0222
* Refer to the I/O Refreshing Methods in the USER’S MANUAL (Cat. No. W524) for the communications cycles for each
model.

Optional Products

Product name Specification Model
Unit/Terminal Block Coding Pins For 10 Units (Terminal Block: 30 pins, Unit: 30 pins) NX-AUX02
Product name Specification Model
No. of
terminals
Terminal number
indications
Ground
terminal mark
Terminal current
capacity
Terminal Block 12 A/B None 10 A NX-TBA122
16 A/B NX-TBA162
12 C/D NX-TBB122

 

General Specification

Item Specification
Enclosure Mounted in a panel
Grounding method Ground to less than 100 Ω
Operating
environment
Ambient operating temperature 0 to 55°C
Ambient operating humidity 10% to 95% (with no condensation or icing)
Atmosphere Must be free from corrosive gases.
Ambient storage temperature -25 to 70°C (with no condensation or icing)
Altitude 2,000 m max.
Pollution degree Pollution degree 2 or less: Conforms to JIS B3502 and IEC 61131-2.
Noise immunity Conforms to IEC61000-4-4, 2 kV (power supply line)
Overvoltage category Category II: Conforms to JIS B3502 and IEC 61131-2.
EMC immunity level Zone B
Vibration resistance Conforms to IEC 60068-2-6.
5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz, acceleration of
9.8 m/s2, 100 min each in X, Y, and Z directions (10 sweeps of 10
min each = 100 min total)
Shock resistance Conforms to IEC 60068-2-27. 147 m/s2, 3 times each in X, Y, and
Z directions
Applicable standards * cULus: Listed (UL508) or Listed (UL 61010-2-201),ANSI/ISA
12.12.01,
EU: EN 61131-2, C-Tick or RCM, KC Registration, NK, LR

*Ask your OMRON representative for the most recent applicable standards for each model.

Incremental Encoder Input Unit Specifications

Incremental Encoder Input Unit

NX-EC0112

Unit name Incremental Encoder Input Unit Model NX-EC0112
Number of channels 1 channel Type of external
connections
Screwless clamping terminal block
(16 terminals)
I/O refreshing method Free-Run refreshing, synchronous I/O refreshing or task period prioritized refreshing *
Indicators 3190_sp_2_1 Input signals Counter: Phases A, B, and Z
External Inputs: 3
Input form Voltage input (24 V)
Counting unit Pulses
Pulse input method Phase differential pulse (multiplication x2/4), pulse + direction inputs,
or up and down pulse inputs
Counter range -2,147,483,648 to 2,147,483,647 pulses
Counter functions
Counter type Ring counter or linear counter
Counter controls Gate control, counter reset, and counter preset
Latch function Two external input latches and one internal latch
Measurements Two external input latches and one internal latch
Voltage input specifications
Input voltage 20.4 to 28.8 VDC
(24 VDC +20%/-15%)
ON voltage 19.6 VDC min./3 mA min.
Input current 4.2 mA typical (24 VDC) OFF voltage 4.0 VDC max./1 mA max.
Maximum response
frequency
Phases A and B: Single-phase 500 kHz (phase differential pulse input x4: 125 kHz),
Phase Z: 125 kHz
Internal I/O common
processing
NPN
External input specifications
Input voltage 20.4 to 28.8 VDC
(24 VDC +20%, -15%)
ON voltage/
ON current
15 VDC min./3 mA min.
Input current 4.6 mA typical (24 VDC) OFF voltage/
OFF current
4.0 VDC max./1 mA max.
ON/OFF response
time
1 μs max./2 μs max.
Internal I/O common
processing
NPN
Dimensions 12 × 100 × 71 mm
(W × H × D)
Isolation method Photocoupler isolation
Insulation resistance 20 MΩ min. between isolated
circuits (at 100 VDC)
Dielectric
strength
510 VAC between isolated circuits
for 1 minute with leakage current
of 5 mA max.
I/O power supply
method
Supplied from the NX bus.
20.4 to 28.8 VDC
(24 VDC +20%, -15%)
Current capacity
of I/O power
supply terminals
IOV: 0.3 A max. per terminal for
encoder supply section and 0.1 A
max. per terminal for other
sections
IOG: 0.3 A max. per terminal for
encoder supply section and 0.1 A
max. per terminal for other
sections
NX Unit power
consumption
• Connected to a CPU Unit
1.15 W max.
• Connected to a Commu-
nications Coupler Unit
0.85 W max.
Current
consumption from
I/O power supply
None
Weight 70 g max.
Circuit layout 3190_sp_2_2
Installation orientation
and restrictions
Installation orientation:
• Connected to a CPU Unit: Possible in upright installation.
• Connected to a Communications Coupler Unit: Possible in 6 orientations.
Restrictions: There are no restrictions.
Terminal connection
diagram
3190_sp_2_3
Failure detection None Protection None

* The I/O refreshing method is automatically set according to the connected Communications Coupler Unit and CPU Unit.

NX-EC0122

Unit name Incremental Encoder Input Unit Model NX-EC0122
Number of channels 1 channel Type of external
connections
Screwless push-in terminal block
(16 terminals)
I/O refreshing method Free-Run refreshing, synchronous I/O refreshing or task period prioritized refreshing *
Indicators 3190_sp_3_1 Input signals Counter: Phases A, B, and Z
External Inputs: 3
Input form Voltage input (24 V)
Counting unit Pulses
Pulse input method Phase difference pulse (multiplication x2/4), pulse + direction inputs,
or up and down pulse inputs
Counter range -2,147,483,648 to 2,147,483,647 pulses
Counter functions
Counter type Ring counter or linear counter
Counter controls Gate control, counter reset, and counter preset
Latch function Two external input latches and one internal latch
Measurements Two external input latches and one internal latch
Voltage input specifications
Input voltage 20.4 to 28.8 VDC
(24 VDC +20%/-15%)
ON voltage 19.6 VDC min./3 mA min.
Input current 4.2 mA typical (24 VDC) OFF voltage 4.0 VDC max./1 mA max.
Maximum response
frequency
Phases A and B: Single-phase 500 kHz (phase difference pulse input x4: 125 kHz),
Phase Z: 125 kHz
Internal I/O common
processing
PNP
External input specifications
Input voltage 20.4 to 28.8 VDC
(24 VDC +20%/-15%)
ON voltage/
ON current
15 VDC min./3 mA min.
Input current 4.6 mA typical (24 VDC) OFF voltage/
OFF current
4.0 VDC max./1 mA max.
ON/OFF response
time
1 μs max./2 μs max.
Internal I/O common
processing
PNP
Dimensions 12 × 100 × 71 mm
(W × H × D)
Isolation method Photocoupler isolation
Insulation resistance 20 MΩ min. between isolated
circuits (at 100 VDC)
Dielectric
strength
510 VAC between isolated circuits
for 1 minute with leakage current
of 5 mA max.
I/O power supply
source
Supplied from the NX bus.
20.4 to 28.8 VDC
(24 VDC +20%/-15%)
Current capacity
of I/O power
supply terminals
IOV: 0.3 A max. per terminal for
encoder supply section and 0.1 A
max. per terminal for other
sections
IOG: 0.3 A max. per terminal for
encoder supply section and 0.1 A
max. per terminal for other
sections
NX Unit power
consumption
• Connected to a CPU Unit
1.30 W max.
• Connected to a Commu-
nications Coupler Unit
0.95 W max.
Current
consumption from
I/O power supply
None
Weight 70 g max.
Circuit layout 3190_sp_3_2
Installation orientation
and restrictions
Installation orientation:
• Connected to a CPU Unit: Possible in upright installation.
• Connected to a Communications Coupler Unit: Possible in 6 orientations.
Restrictions: There are no restrictions.
Terminal connection
diagram
3190_sp_3_3
Failure detection None Protection None

* The I/O refreshing method is automatically set according to the connected Communications Coupler Unit and CPU Unit.

NX-EC0132

Unit name Incremental Encoder Input Unit Model NX-EC0132
Number of channels 1 channel Type of external
connections
Screwless clamping terminal block
(12 terminals × 2)
I/O refreshing method Free-Run refreshing, synchronous I/O refreshing or task period prioritized refreshing *
Indicators 3190_sp_4_1 Input signals Counter: Phases A, B, and Z
External Inputs: 3
Input form Line receiver input
Counting unit Pulses
Pulse input method Phase differential pulse (multiplication x2/4), pulse + direction inputs,
or up and down pulse inputs
Counter range -2,147,483,648 to 2,147,483,647 pulses
Counter functions
Counter type Ring counter or linear counter
Counter controls Gate control, counter reset, and counter preset
Latch function Two external input latches and one internal latch
Measurements Pulse rate measurement and pulse period measurement
Line driver specifications
Input voltage EIA standard RS-422-A line
driver levels
High level input
voltage
VIT+: 0.1 V min.
Input impedance 120 Ω ± 5% Low level input
voltage
VIT-: -0.1 V min.
Hysteresis voltage Vhys (VIT+ – VIT-): 60 mV
Maximum response
frequency
Phases A and B: Single-phase 4 MHz (phase differential pulse input x4: 1 MHz),
Phase Z: 1 MHz
5-V power supply for
encoder
Output voltage: 5 VDC ±5%
Output current: 500 mA max.
External input specifications
Input voltage 20.4 to 28.8 VDC
(24 VDC +20%, -15%)
ON voltage/
ON current
15 VDC min./3 mA min.
Input current 3.5 mA typical (24 VDC) OFF voltage/
OFF current
5.0 VDC max./1 mA max.
ON/OFF response
time
1 μs max./1 μs max.
Internal I/O common
processing
NPN
Dimensions 12 × 100 × 71 mm
(W × H × D)
Isolation method Digital isolator
Insulation resistance 20 MΩ min. between isolated
circuits (at 100 VDC)
Dielectric
strength
510 VAC between isolated circuits
for 1 minute with leakage current
of 5 mA max.
I/O power supply
method
Supplied from the NX bus.
20.4 to 28.8 VDC
(24 VDC +20%, -15%)
Current capacity
of I/O power
supply terminals
IOV: 0.1 A max. per terminal
IOG: 0.1 A max. per terminal
NX Unit power
consumption
• Connected to a CPU Unit
1.25 W max.
• Connected to a Commu-
nications Coupler Unit
0.95 W max.
Current
consumption from
I/O power supply
Unit current consumption: 30 mA max.
Consumption from encoder
5-V power supply:
0.28 × Encoder current consumption mA
Weight 130 g max.
Circuit layout 3190_sp_4_2
Installation orientation
and restrictions
Installation orientation:
• Connected to a CPU Unit: Possible in upright installation.
• Connected to a Communications Coupler Unit: Possible in 6 orientations.
Restrictions: There are no restrictions.
Terminal connection
diagram
3190_sp_4_3
Failure detection None Protection None

* The I/O refreshing method is automatically set according to the connected Communications Coupler Unit and CPU Unit.

NX-EC0142

Unit name Incremental Encoder Input Unit Model NX-EC0142
Number of channels 1 channel Type of external
connections
Screwless push-in terminal block
(12 terminals × 2)
I/O refreshing method Free-Run refreshing, synchronous I/O refreshing or task period prioritized refreshing *
Indicators 3190_sp_5_1 Input signals Counter: Phases A, B, and Z
External Inputs: 3
Input form Line receiver input
Counting unit Pulses
Pulse input method Phase difference pulse (multiplication x2/4), pulse + direction inputs,
or up and down pulse inputs
Counter range -2,147,483,648 to 2,147,483,647 pulses
Counter functions
Counter type Ring counter or linear counter
Counter controls Gate control, counter reset, and counter preset
Latch function Two external input latches and one internal latch
Measurements Pulse rate measurement and pulse period measurement
Line driver specifications
Input voltage EIA standard RS-422-A line
driver levels
High level input
voltage
VIT+: 0.1 V min.
Input impedance 120 Ω ± 5% Low level input
voltage
VIT-: -0.1 V min.
Hysteresis voltage Vhys (VIT+ – VIT-): 60 Mv
Maximum response
frequency
Phases A and B: Single-phase 4 MHz (phase difference pulse input x4: 1 MHz),
Phase Z: 1 MHz
5-V power supply for
encoder
Output voltage: 5 VDC
Output current: 500 mA max.
External input specifications
Input voltage 20.4 to 28.8 VDC
(24 VDC +20%/.15%)
ON voltage/
ON current
15 VDC min./3 mA min.
Input current 3.5 mA typical (24 VDC) OFF voltage/
OFF current
4.0 VDC max./1 mA max.
ON/OFF response
time
1 μs max./2 μs max.
Internal I/O common
processing
PNP
Dimensions 12 × 100 × 71 mm
(W × H × D)
Isolation method Photocoupler isolation
Insulation resistance 20 MΩ min. between isolated
circuits (at 100 VDC)
Dielectric
strength
510 VAC between isolated circuits
for 1 minute with leakage current
of 5 mA max.
I/O power supply
source
Supplied from the NX bus.
20.4 to 28.8 VDC
(24 VDC +20%/-15%)
Current capacity
of I/O power
supply terminals
IOV: 0.1 A max. per terminal
IOG: 0.1 A max. per terminal
NX Unit power
consumption
• Connected to a CPU Unit
1.50 W max.
• Connected to a Commu-
nications Coupler Unit
1.05 W max.
Current
consumption from
I/O power supply
Unit current consumption: 30 mA max.
Consumption from encoder
5-V power supply:
0.28 × Encoder current consumption mA
Weight 130 g max.
Circuit layout 3190_sp_5_2
Installation orientation
and restrictions
Installation orientation:
• Connected to a CPU Unit: Possible in upright installation.
• Connected to a Communications Coupler Unit: Possible in 6 orientations.
Restrictions: There are no restrictions.
Terminal connection
diagram
3190_sp_5_3
Failure detection None Protection None

* The I/O refreshing method is automatically set according to the connected Communications Coupler Unit and CPU Unit.

NX-EC0212

Unit name Incremental Encoder Input Unit Model NX-EC0212
Number of channels 2 channels Type of external
connections
Screwless clamping terminal block
(12 terminals)
I/O refreshing method Free-Run refreshing, synchronous I/O refreshing or task period prioritized refreshing *
Indicators 3190_sp_6_1 Input signals Counter: Phases A, B, and Z
External Inputs: None
Input form Voltage input (24 V)
Counting unit Pulses
Pulse input method Phase differential pulse (multiplication x2/4), pulse + direction inputs,
or up and down pulse inputs
Counter range -2,147,483,648 to 2,147,483,647 pulses
Counter functions
Counter type Ring counter or linear counter
Counter controls Gate control, counter reset, and counter preset
Latch function Two external input latches and one internal latch
Measurements Two external input latches and one internal latch
Voltage input specifications
Input voltage 20.4 to 28.8 VDC
(24 VDC +20%, -15%)
ON voltage 19.6 VDC min./3 mA min.
Input current 4.2 mA typical (24 VDC) OFF voltage 4.0 VDC max./1 mA max.
Maximum response
frequency
Phases A and B: Single-phase 500 kHz (phase differential pulse input x4: 125 kHz),
Phase Z: 125 kHz
Internal I/O common
processing
NPN
External input specifications
Input voltage ON voltage/
ON current
Input current OFF voltage/
OFF current
ON/OFF response time
Internal I/O common
processing
Dimensions 12 × 100 × 71 mm
(W × H × D)
Isolation method Photocoupler isolation
Insulation resistance 20 MΩ min. between isolated
circuits (at 100 VDC)
Dielectric
strength
510 VAC between isolated circuits
for 1 minute with leakage current
of 5 mA max.
I/O power supply
method
Supplied from the NX bus.
20.4 to 28.8 VDC
(24 VDC +20%, -15%)
Current capacity
of I/O power
supply terminals
IOV: 0.3 A max. per terminal
IOG: 0.3 A max. per terminal
NX Unit power
consumption
• Connected to a CPU Unit
1.15 W max.
• Connected to a Commu-
nications Coupler Unit
0.85 W max.
Current
consumption from
I/O power supply
None
Weight 70 g max.
Circuit layout 3190_sp_6_2
Installation orientation
and restrictions
Installation orientation:
• Connected to a CPU Unit: Possible in upright installation.
• Connected to a Communications Coupler Unit: Possible in 6 orientations.
Restrictions: There are no restrictions.
Terminal connection
diagram
3190_sp_6_3
Failure detection None Protection None

* The I/O refreshing method is automatically set according to the connected Communications Coupler Unit and CPU Unit.

NX-EC0222

Unit name Incremental Encoder Input Unit Model NX-EC0222
Number of channels 2 channels Type of external
connections
Screwless push-in terminal block
(12 terminals)
I/O refreshing method Free-Run refreshing, synchronous I/O refreshing or task period prioritized refreshing *
Indicators 3190_sp_7_1 Input signals Counter: Phases A, B, and Z
External Inputs: None
Input form Voltage input (24 V)
Counting unit Pulses
Pulse input method Phase difference pulse (multiplication x2/4), pulse + direction inputs,
or up and down pulse 3inputs
Counter range -2,147,483,648 to 2,147,483,647 pulses
Counter functions
Counter type Ring counter or linear counter
Counter controls Gate control, counter reset, and counter preset
Latch function Two external input latches and one internal latch
Measurements Two external input latches and one internal latch
Voltage input specifications
Input voltage 20.4 to 28.8 VDC
(24 VDC +20%/-15%)
ON voltage 19.6 VDC min./3 mA min.
Input current 4.2 mA typical (24 VDC) OFF voltage 4.0 VDC max./1 mA max.
Maximum response
frequency
Phases A and B: Single-phase 500 kHz (phase difference pulse input x4: 125 kHz),
Phase Z: 125 kHz
Internal I/O common
processing
PNP
External input specifications
Input voltage ON voltage/
ON current
Input current OFF voltage/
OFF current
ON/OFF response
time
Internal I/O common
processing
Dimensions 12 × 100 × 71 mm
(W × H × D)
Isolation method Photocoupler isolation
Insulation resistance 20 MΩ min. between isolated
circuits (at 100 VDC)
Dielectric
strength
510 VAC between isolated circuits
for 1 minute with leakage current
of 5 mA max.
I/O power supply
source
Supplied from the NX bus.
20.4 to 28.8 VDC
(24 VDC +20%/-15%)
Current capacity
of I/O power
supply terminals
IOV: 0.3 A max. per terminal
IOG: 0.3 A max. per terminal
NX Unit power
consumption
• Connected to a CPU Unit
1.30 W max.
• Connected to a Commu-
nications Coupler Unit
0.95 W max.
Current
consumption from
I/O power supply
None
Weight 70 g max.
Circuit layout 3190_sp_7_2
Installation orientation
and restrictions
Installation orientation:
• Connected to a CPU Unit: Possible in upright installation.
• Connected to a Communications Coupler Unit: Possible in 6 orientations.
Restrictions: There are no restrictions.
Terminal connection
diagram
3190_sp_7_3
Failure detection None Protection None

* The I/O refreshing method is automatically set according to the connected Communications Coupler Unit and CPU Unit.

Version Information

Connected to a CPU Unit

Refer to the user’s manual for the CPU Unit details on the CPU Units to which NX Units can be connected.

NX Unit Corresponding unit versions/versions
Model Unit version CPU Unit Sysmac Studio
NX-EC0112 Ver. 1.1 Ver.1.13 Ver.1.17
Ver. 1.2
NX-EC0122 Ver. 1.0 Ver.1.13 Ver.1.17
Ver. 1.1
Ver. 1.2
NX-EC0132 Ver. 1.1 Ver.1.13 Ver.1.17
Ver. 1.2
NX-EC0142 Ver. 1.0 Ver.1.13 Ver.1.17
Ver. 1.1
Ver. 1.2
NX-EC0212 Ver. 1.1 Ver.1.13 Ver.1.17
Ver. 1.2
NX-EC0222 Ver. 1.0 Ver.1.13 Ver.1.17
Ver. 1.1
Ver. 1.2

Note: Some Units do not have all of the versions given in the above table. If a Unit does not have the specified version, support is provided by the oldest available version after the specified version. Refer to the user’s manuals for the specific Units for the relation between models and versions.

Connected to an EtherCAT Coupler Unit

NX Unit Corresponding unit versions/versions
Model Unit version EtherCAT
Coupler Unit
CPU Unit or Industrial PC Sysmac Studio
NX-EC0112 Ver. 1.1 Ver. 1.1 *1 Ver. 1.06 *1 Ver. 1.10
Ver. 1.2 Ver. 1.3 *2*3 Ver. 1.13
NX-EC0122 Ver. 1.0 Ver. 1.1 *1 Ver. 1.06 *1 Ver. 1.07
Ver. 1.1 Ver. 1.08
Ver. 1.2 Ver. 1.3 *2*3 Ver. 1.13
NX-EC0132 Ver. 1.1 Ver. 1.1 *1 Ver. 1.06 *1 Ver. 1.10
Ver. 1.2 Ver. 1.3 *2*3 Ver. 1.13
NX-EC0142 Ver. 1.0 Ver. 1.1 *1 Ver. 1.06 *1 Ver. 1.07
Ver. 1.1 Ver. 1.08
Ver. 1.2 Ver. 1.3 *2*3 Ver. 1.13
NX-EC0212 Ver. 1.1 Ver. 1.1 *1 Ver. 1.06 *1 Ver. 1.10
Ver. 1.2 Ver. 1.3 *2*3 Ver. 1.13
NX-EC0222 Ver. 1.0 Ver. 1.1 *1 Ver. 1.06 *1 Ver. 1.07
Ver. 1.1 Ver. 1.08
Ver. 1.2 Ver. 1.3 *2*3 Ver. 1.13

Note: Some Units do not have all of the versions given in the above table. If a Unit does not have the specified version, support is provided by the oldest available version after the specified version. Refer to the user’s manuals for the specific Units for the relation between models and versions.
*1. You can use the following versions if time stamp refreshing is not used.
*2. To use task period prioritized refreshing, you must use the NX-ECC203.
*3. If you do not use task period prioritized refreshing, you can use EtherCAT Coupler Units which support Position Interface Units with unit version 1.1 or earlier.
*4. If you do not use task period prioritized refreshing, you can use EtherCAT Coupler Units with unit version 1.0.

Connected to an EtherNet/IP Coupler Unit

NX Unit Corresponding unit versions/versions
Model Unit
version
Application with an NJ/NX/NY-series Controller
*1
Application with a CS/CJ/CP-series PLC *2
EtherNet/IP
Coupler Unit
CPU Unit or
Industrial PC
Sysmac
Studio
EtherNet/IP
Coupler Unit
Sysmac
Studio
NX-IO
Configurator *3
NX-EC0112 Ver. 1.1 Ver. 1.2 Ver. 1.14 Ver. 1.19 Ver. 1.0 Ver. 1.10 Ver. 1.00
Ver. 1.2 Ver. 1.13
NX-EC0122 Ver. 1.0 Ver. 1.2 Ver. 1.14 Ver. 1.19 Ver. 1.0 Ver. 1.10 Ver. 1.00
Ver. 1.1
Ver. 1.2 Ver. 1.13
NX-EC0132 Ver. 1.1 Ver. 1.2 Ver. 1.14 Ver. 1.19 Ver. 1.0 Ver. 1.10 Ver. 1.00
Ver. 1.2 Ver. 1.13
NX-EC0142 Ver. 1.0 Ver. 1.2 Ver. 1.14 Ver. 1.19 Ver. 1.0 Ver. 1.10 Ver. 1.00
Ver. 1.1
Ver. 1.2 Ver. 1.13
NX-EC0212 Ver. 1.1 Ver. 1.2 Ver. 1.14 Ver. 1.19 Ver. 1.0 Ver. 1.10 Ver. 1.00
Ver. 1.2 Ver. 1.13
NX-EC0222 Ver. 1.0 Ver. 1.2 Ver. 1.14 Ver. 1.19 Ver. 1.0 Ver. 1.10 Ver. 1.00
Ver. 1.1
Ver. 1.2 Ver. 1.13

Note: 1. Some Units do not have all of the versions given in the above table. If a Unit does not have the specified version, support is provided by the oldest available version after the specified version. Refer to the user’s manuals for the specific Units for the relation between models and versions.
Note: 2. You cannot connect the relevant NX Unit or use the relevant NX Unit function if “—” is shown in the corresponding unit versions/versions column.
*1. Refer to the user’s manual of the EtherNet/IP Coupler Unit for the unit versions of EtherNet/IP Units corresponding to EtherNet/IP Coupler Units.
*2. Refer to the user’s manual of the EtherNet/IP Coupler Unit for the unit versions of CPU Units and EtherNet/IP Units corresponding to EtherNet/IP Coupler Units.
*3. For connection to an EtherNet/IP Coupler Unit with unit version 1.0, connection is supported only for a connection to the peripheral USB port on the EtherNet/IP Coupler Unit. You cannot connect by any other path. If you need to connect by another path, use an EtherNet/IP Coupler Unit with unit version 1.2 or later.

 

(Unit: mm)

Screwless Clamping Terminal Block Type

12 mm Width

NX-EC0[][][] Dimensions 2

24 mm Width

NX-EC0[][][] Dimensions 3
Catalog Name
Catalog Number
[size]
Last Update
 NX-EC0/ECS/PG0 Data Sheet
[7485KB]
Aug 01, 2018
 NX-series I/O System Catalog R183-E1-09
[6683KB]
Nov 01, 2018

Reviews

There are no reviews yet.

Be the first to review “NX-ECS[][][]”

Your email address will not be published. Required fields are marked *



Exclusive products

Special category of products