{"id":960,"date":"2018-12-27T05:05:09","date_gmt":"2018-12-27T05:05:09","guid":{"rendered":"http:\/\/al-tet-onlinesales.allyoulovetrading.com\/?post_type=product&#038;p=960"},"modified":"2018-12-27T05:06:12","modified_gmt":"2018-12-27T05:06:12","slug":"mdr-40","status":"publish","type":"product","link":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/product\/mdr-40\/","title":{"rendered":"MDR-40"},"content":{"rendered":"<div class=\"xgeffect\">\n<div class=\"detalist\">\n<p>\u00a0Features :<br \/>\n\u2022Universal AC input\/Full range<br \/>\n\u2022Protections: Short circuit \/ Overload \/ Over voltage<br \/>\n\u2022Cooling by free air convection<br \/>\n\u2022Can be installed on DIN rail TS-35\/7.5 or 15<br \/>\n\u2022Isolation class n<br \/>\n\u2022LED indicator for power on<br \/>\n\u2022100% full load burn-in test<br \/>\n\u20223 years warranty<\/p>\n<p>SPECIFICATION<\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"214\">MODEL<\/td>\n<td valign=\"top\" width=\"120\">MDR-40-5<\/td>\n<td valign=\"top\" width=\"121\">MDR-40-12<\/td>\n<td valign=\"top\" width=\"121\">MDR-40-24<\/td>\n<td valign=\"top\" width=\"122\">MDR-40-48<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"11\" valign=\"top\" width=\"90\">OUTPUT<\/td>\n<td valign=\"center\" width=\"123\">DC VOLTAGE<\/td>\n<td valign=\"center\" width=\"120\">5V<\/td>\n<td valign=\"center\" width=\"121\">12V<\/td>\n<td valign=\"center\" width=\"121\">24V<\/td>\n<td valign=\"center\" width=\"122\">48V<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"123\">RATED CURRENT<\/td>\n<td valign=\"center\" width=\"120\">6A<\/td>\n<td valign=\"center\" width=\"121\">3.3A<\/td>\n<td valign=\"center\" width=\"121\">1.67A<\/td>\n<td valign=\"center\" width=\"122\">0.83A<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"123\">CURRENT RANGE<\/td>\n<td valign=\"center\" width=\"120\">0~6A<\/td>\n<td valign=\"center\" width=\"121\">0-3.3A<\/td>\n<td valign=\"center\" width=\"121\">0 ~ 1.67A<\/td>\n<td valign=\"center\" width=\"122\">0 ~ 0.83A<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"123\">RATED POWER<\/td>\n<td valign=\"center\" width=\"120\">30W<\/td>\n<td valign=\"center\" width=\"121\">40W<\/td>\n<td valign=\"center\" width=\"121\">40W<\/td>\n<td valign=\"center\" width=\"122\">40W<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"123\">RIPPLE &amp; NOISE (max.)<\/td>\n<td valign=\"center\" width=\"120\">80mVp-p<\/td>\n<td valign=\"center\" width=\"121\">120mVp-p<\/td>\n<td valign=\"center\" width=\"121\">150mVp-p<\/td>\n<td valign=\"center\" width=\"122\">200mVp-p<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"123\">VOLTAGE ADJ. RANGE<\/td>\n<td valign=\"center\" width=\"120\">5-6V<\/td>\n<td valign=\"center\" width=\"121\">12 ~ 15V<\/td>\n<td valign=\"center\" width=\"121\">24 &#8211; 30V<\/td>\n<td valign=\"center\" width=\"122\">48 &#8211; 56V<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"123\">VOLTAGE TOLERANCE<\/td>\n<td valign=\"center\" width=\"120\">\u00b12.0%<\/td>\n<td valign=\"center\" width=\"121\">\u00b11.0%<\/td>\n<td valign=\"center\" width=\"121\">\u00b11.0%<\/td>\n<td valign=\"center\" width=\"122\">\u00b11.0%<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"123\">LINE REGULATION<\/td>\n<td valign=\"center\" width=\"120\">\u00b11.0%<\/td>\n<td valign=\"center\" width=\"121\">\u00b11.0%<\/td>\n<td valign=\"center\" width=\"121\">\u00b11.0%<\/td>\n<td valign=\"center\" width=\"122\">\u00b11.0%<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"123\">LOAD REGULATION<\/td>\n<td valign=\"center\" width=\"120\">\u00b11.0%<\/td>\n<td valign=\"center\" width=\"121\">\u00b11.0%<\/td>\n<td valign=\"center\" width=\"121\">\u00b11.0%<\/td>\n<td valign=\"center\" width=\"122\">\u00b11.0%<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"123\">SETUP, RISE TIME<\/td>\n<td colspan=\"4\" valign=\"center\" width=\"485\">500ms, 30ms\/230VAC 500ms, 30ms\/115VAC at full load<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"123\">HOLD UP TIME (Typ.)<\/td>\n<td colspan=\"4\" valign=\"center\" width=\"485\">50ms\/230VAC 20ms\/115VAC at full load<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\" valign=\"top\" width=\"90\">INPUT<\/td>\n<td valign=\"center\" width=\"123\">VOLTAGE RANGE<\/td>\n<td colspan=\"4\" valign=\"center\" width=\"485\">85 ~ 264VAC 120-370VDC<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"123\">FREQUENCY RANGE<\/td>\n<td colspan=\"4\" valign=\"center\" width=\"485\">47~63Hz<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"123\">EFFICIENCY (Typ.)<\/td>\n<td valign=\"center\" width=\"120\">78%<\/td>\n<td valign=\"center\" width=\"121\">86%<\/td>\n<td valign=\"center\" width=\"121\">88%<\/td>\n<td valign=\"center\" width=\"122\">88%<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"123\">AC CURRENT (Typ.)<\/td>\n<td colspan=\"4\" valign=\"center\" width=\"485\">1.1 A\/115 VAC 0.7A\/230VAC<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"123\">INRUSH CURRENT (Typ.)<\/td>\n<td colspan=\"4\" valign=\"center\" width=\"485\">COLD START 30A\/115VAC,60A\/230VAC<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"123\">LEAKAGE CURRENT<\/td>\n<td colspan=\"4\" valign=\"top\" width=\"485\">&lt;1mA\/240VAC<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" valign=\"top\" width=\"90\">PROTECTION<\/td>\n<td rowspan=\"2\" valign=\"center\" width=\"123\">OVERLOAD<\/td>\n<td colspan=\"4\" valign=\"center\" width=\"485\">105 ~ 150% rated output power<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" valign=\"center\" width=\"485\">Protection type: Constant current limiting, recovers automatically after fault condition is removed<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" valign=\"center\" width=\"123\">OVERVOLTAGE<\/td>\n<td valign=\"center\" width=\"120\">6.25 &#8211; 7.25V<\/td>\n<td valign=\"center\" width=\"121\">15.6 -18V<\/td>\n<td valign=\"center\" width=\"121\">31.2-36V<\/td>\n<td valign=\"center\" width=\"122\">57.6-64.8V<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" valign=\"center\" width=\"485\">Protection type : Shut down o\/p voltage, re-power on to recover<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"90\">FUNCTION<\/td>\n<td valign=\"center\" width=\"123\">DC OK SIGNAL<\/td>\n<td colspan=\"4\" valign=\"center\" width=\"485\">Relay contact rating{max.): 30V\/1A resistive<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" valign=\"top\" width=\"90\">ENVIRONMENT<\/td>\n<td valign=\"center\" width=\"123\">WORKING TEMP.<\/td>\n<td colspan=\"4\" valign=\"center\" width=\"485\">-20 ~ +70\u201cC (Refer to &#8220;Derating Curve&#8221;)<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"123\">WORKING HUMIDITY<\/td>\n<td colspan=\"4\" valign=\"center\" width=\"485\">20 &#8211; 90% RH non-condensing<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"123\">STORAGE TEMP, HUMIDITY<\/td>\n<td colspan=\"4\" valign=\"center\" width=\"485\">-40 ~ +85\u00b0C, 10 ~ 95% RH<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"123\">TEMP. COEFFICIENT<\/td>\n<td colspan=\"4\" valign=\"center\" width=\"485\">\u00b10.03%\/\u00b0C (0 ~50\u00b0C)<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"123\">VIBRATION<\/td>\n<td colspan=\"4\" valign=\"center\" width=\"485\">Component: 10 &#8211; 500Hz, 2G 10min.\/1 cycle, period for60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" valign=\"top\" width=\"90\">OTHERS<\/td>\n<td valign=\"center\" width=\"123\">MTBF<\/td>\n<td colspan=\"4\" valign=\"center\" width=\"485\">301.7K hrs min. MIL-HDBK-217F (25\u00b0C)<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"123\">DIMENSION<\/td>\n<td colspan=\"4\" valign=\"center\" width=\"485\">40*90*100mm (W*H*D)<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"123\">PACKING<\/td>\n<td colspan=\"4\" valign=\"center\" width=\"485\">0.3Kg; 40pcs\/17Kg\/0.82CUFT<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div class=\"xgeffect\">\n<div class=\"detailtop\"><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u2022Universal AC input\/Full range<br \/>\n\u2022Protections: Short circuit \/ Overload \/ Over voltage<br \/>\n\u2022Cooling by free air convection<br \/>\n\u2022Can be installed on DIN rail TS-35\/7.5 or 15<br \/>\n\u2022Isolation class n<br \/>\n\u2022LED indicator for power on<br \/>\n\u2022100% full load burn-in test<br \/>\n\u20223 years warranty<\/p>\n","protected":false},"featured_media":755,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[78],"product_tag":[],"_links":{"self":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product\/960"}],"collection":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/comments?post=960"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/media\/755"}],"wp:attachment":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/media?parent=960"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=960"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=960"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}