{"id":1583,"date":"2019-01-03T10:41:21","date_gmt":"2019-01-03T10:41:21","guid":{"rendered":"http:\/\/al-tet-onlinesales.allyoulovetrading.com\/?post_type=product&#038;p=1583"},"modified":"2019-01-03T10:41:21","modified_gmt":"2019-01-03T10:41:21","slug":"cj1w-srm21-2","status":"publish","type":"product","link":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/product\/cj1w-srm21-2\/","title":{"rendered":"CJ1W-SRM21"},"content":{"rendered":"<p>\u2022 Up to 256 I\/O points per Master.<\/p>\n<p>\u2022 Up to 32 Slaves per Master.<\/p>\n<p>\u2022 Communications cycle time: 0.5 ms (at 750 kbps).<\/p>\n<p>\u2022 Communications distance: Up to 500 m (at 93.75 kbps).<\/p>\n<p>\u2022 Free wiring with any branching method for up to 200 m (in long-distance communications mode).<\/p>\n<p>&nbsp;<\/p>\n<h4 class=\"heading-B02\">International Standards<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<ul class=\"listA01\">\n<li>The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.<\/li>\n<li>Contact your OMRON representative for further details and applicable conditions for these standards.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Unit<br \/>\ntype<\/strong><\/th>\n<td class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Name<\/strong><\/td>\n<th class=\"heading center middle\" colspan=\"3\" rowspan=\"1\"><strong>Specifications<\/strong><\/th>\n<td class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>No. of<br \/>\nunit<br \/>\nnumbers<br \/>\nallocated<\/strong><\/td>\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Current con-<br \/>\nsumption (A)<\/strong><\/th>\n<td class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/td>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Stand-<br \/>\nards<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Communi-<br \/>\ncations<br \/>\nfunctions<\/strong><\/th>\n<td class=\"heading center middle\"><strong>No. of I\/O<br \/>\npoints<\/strong><\/td>\n<th class=\"heading center middle\"><strong>Max. Units<br \/>\nmountable<br \/>\nper CPU<br \/>\nUnit<\/strong><\/th>\n<td class=\"heading center middle\"><strong>5 V<\/strong><\/td>\n<th class=\"heading center middle\"><strong>24 V<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>CJ1<br \/>\nSpecial<br \/>\nI\/O<br \/>\nUnits<\/strong><\/th>\n<td class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>CompoBus\/S<br \/>\nMaster Unit<\/strong><\/p>\n<div class=\"image\"><strong><img src=\"http:\/\/www.ia.omron.com\/tab\/family\/30\/img\/cj1w-srm21_lu_1_1.gif\" \/><\/strong><\/div>\n<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">Remote I\/O<br \/>\ncommuni-<br \/>\ncations<\/td>\n<td class=\"left middle\">256 max.<br \/>\n(128 inputs<br \/>\nand<br \/>\n128 outputs)<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">40<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">1 or 2<br \/>\n(variable)<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">0.15<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">&#8212;<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\"><strong>CJ1W-SRM21<\/strong><\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">UC1,<br \/>\nN, L,<br \/>\nCE,<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">128 max.<br \/>\n(64 inputs<br \/>\nand<br \/>\n64 outputs)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Note: This unit cannot be used with the Machine Automation Controller NJ-series.<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h4 class=\"heading-A02\">Communication Specifications<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Item<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Specification<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Communications method<\/strong><\/th>\n<td class=\"left middle\">Special CompoBus\/S protocol<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Communications baud rate<\/strong><\/th>\n<td class=\"left middle\">High-speed Communications Mode: 750 kbps<br \/>\nLong-distance Communications Mode: 93.75 kbps<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Modulation method<\/strong><\/th>\n<td class=\"left middle\">Baseband method<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Coding method<\/strong><\/th>\n<td class=\"left middle\">Manchester coding method<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Error control checks<\/strong><\/th>\n<td class=\"left middle\">Manchester code check, frame length check, and parity check<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Cable<\/strong><\/th>\n<td class=\"heading left middle\"><strong>VCTF cable<br \/>\n(JIS C 3306)<\/strong><\/td>\n<td class=\"left middle\">Two 0.75 mm<sup>2<\/sup>\u00a0conductors (2 signal wires)<br \/>\nFour 0.75 mm<sup>2<\/sup>\u00a0conductors (2 signal wires and 2 power supply wires)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Special Flat<br \/>\nCable<\/strong><\/th>\n<td class=\"left middle\">Four 0.75 mm<sup>2<\/sup>\u00a0conductors (2 signal wires and 2 power supply wires)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"6\"><strong>Commu-<br \/>\nnications<br \/>\ndistance<\/strong><\/th>\n<td class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>2-conductor<br \/>\nVCTF cable<\/strong><\/td>\n<td class=\"left middle\">High-speed Communications Mode<br \/>\nMain line length: 100 m max.<br \/>\nBranch line length: 3 m max.<br \/>\nTotal branch line length: 50 m max.<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Long-distance Communications Mode<br \/>\nMain line length: 500 m max.<br \/>\nBranch line length: 6 m max.<br \/>\nTotal branch line length: 120 m max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>4-conductor<br \/>\nVCTF cable<\/strong><\/th>\n<td class=\"left middle\">High-speed Communications Mode<br \/>\nMain line length: 30 m max.<br \/>\nBranch line length: 3 m max.<br \/>\nTotal branch line length: 30 m max.<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Long-distance Communications Mode: Flexibly branched, provided that the total length of<br \/>\ncable is a maximum of 200 m.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Special Flat<br \/>\nCable<\/strong><\/th>\n<td class=\"left middle\">High-speed Communications Mode<br \/>\nMain line length: 30 m max.<br \/>\nBranch line length: 3 m max.<br \/>\nTotal branch line length: 30 m max.<br \/>\nWhen 4-conductor VCTF cable or Special Flat Cable is used to connect fewer than 16<br \/>\nSlaves, the main line can be up to 100 m long and the total branch line length can be up<br \/>\nto 50 m in High-speed Communications Mode.<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Long-distance Communications Mode: Flexibly branched, provided that the total length of<br \/>\ncable is a maximum of 200 m.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Specifications<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading left middle\"><strong>I\/O points<\/strong><\/th>\n<td class=\"left middle\">256 (128 inputs and 128 outputs) or 128 (64 inputs and 64 outputs) (Switch-<br \/>\nselectable)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Applicable PLC models<\/strong><\/th>\n<td class=\"left middle\">CJ-series PLCs<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Unit type<\/strong><\/th>\n<td class=\"left middle\">Special I\/O Unit<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Allocated words *<\/strong><\/th>\n<td class=\"left middle\">For 256 I\/O: 20 words (8 for inputs, 8 for outputs, 4 for status)<br \/>\nFor 128 I\/O: 10 words (4 for inputs, 4 for outputs, 2 for status)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>No. of mountable Master Units<\/strong><\/th>\n<td class=\"left middle\">40<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Node address<\/strong><\/th>\n<td class=\"left middle\">8 addresses per node<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>No. of connectable Slaves<\/strong><\/th>\n<td class=\"left middle\">32<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Status information<\/strong><\/th>\n<td class=\"left middle\">Communications Error Flags, Participation Flags<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>* Uses Special I\/O Unit Area (in CIO Area).<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>(Unit: mm)<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-B02\">CJ1W-SRM21<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/cj1w-srm21_dm_113-110512.gif\" alt=\"CJ1W-SRM21 Dimensions 1 \" \/><\/div>\n<\/div>\n<div><\/div>\n<div><\/div>\n<div>\n<div class=\"inner-contents-area\">\n<div class=\"primary-contents-area\">\n<div class=\"tabpanel-blockA01\">\n<div class=\"editable-block\">\n<div class=\"table-blockA01\">\n<table id=\"global_data\" class=\"tableA01 tablesorter\" border=\"1\" cellspacing=\"0\">\n<thead>\n<tr class=\"tablesorter-header\">\n<th class=\"dl_name\">\n<div class=\"tablesorter-header-inner\">Catalog Name<\/div>\n<\/th>\n<th class=\"dl_cat_number\">\n<div class=\"tablesorter-header-inner\">Catalog Number<br \/>\n[size]<\/div>\n<\/th>\n<th class=\"dl_date tablesorter-header\">\n<div class=\"tablesorter-header-inner\">Last Update<\/div>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"odd first-child\">\n<td><a href=\"http:\/\/www.ia.omron.com\/data_pdf\/cat\/cj1w-srm21_ds_e_2_2_csm1640.pdf?id=30\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" class=\"iconD01\" src=\"http:\/\/www.ia.omron.com\/resources\/images\/icon_pdf.gif\" alt=\"\" width=\"11\" height=\"12\" \/>\u00a0CJ1W-SRM21 Data Sheet<\/a><\/td>\n<td>&#8211;<br \/>\n<span class=\"file-size\">[515KB]<\/span><\/td>\n<td class=\"td_date\">Sep 15, 2016<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"local-navi-area\">\n<div class=\"local-navi-area\">\n<div class=\"local-naviA01\">\n<h2 class=\"heading-link\"><\/h2>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h2 class=\"heading-B02\">CompoBus\/S is a high-speed I\/O bus<\/h2>\n","protected":false},"featured_media":1535,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[91,63,72],"product_tag":[],"_links":{"self":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product\/1583"}],"collection":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/comments?post=1583"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/media\/1535"}],"wp:attachment":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/media?parent=1583"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=1583"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=1583"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}