{"id":1571,"date":"2019-01-03T09:44:39","date_gmt":"2019-01-03T09:44:39","guid":{"rendered":"http:\/\/al-tet-onlinesales.allyoulovetrading.com\/?post_type=product&#038;p=1571"},"modified":"2019-01-03T09:44:43","modified_gmt":"2019-01-03T09:44:43","slug":"cj1w-int01-3","status":"publish","type":"product","link":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/product\/cj1w-int01-3\/","title":{"rendered":"CJ1W-INT01"},"content":{"rendered":"<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>\u2022 High-speed ON response of 0.05 ms<\/p>\n<p>\u2022 Use up to 32 interrupt inputs with up to two Units per CPU Unit.<\/p>\n<p>\u2022 Applicable with both NPN and PNP output devices. Polarity selection is not required. *<\/p>\n<p>* The same polarity is used for the same common.<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h4 class=\"heading-B02\">International Standards<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<ul class=\"listA01\">\n<li>The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.<\/li>\n<li>Contact your OMRON representative for further details and applicable conditions for these standards.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Interrupt Input Units<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Unit type: CJ1 Basic I\/O Units<br \/>\nNo. of words allocated: 1 word<br \/>\nStandards: UC1, N, L, CE<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Product<br \/>\nname<\/strong><\/th>\n<td class=\"heading center middle\" colspan=\"6\" rowspan=\"1\"><strong>Specifications<\/strong><\/td>\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Current<br \/>\nconsumption (A)<\/strong><\/th>\n<td class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>I\/O points<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Input<br \/>\nvoltage<br \/>\ncurrent<\/strong><\/td>\n<th class=\"heading center middle\"><strong>Commons<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Input pulse<br \/>\nwidth<br \/>\nconditions<\/strong><\/td>\n<th class=\"heading center middle\"><strong>Max. Units<br \/>\nmountable<br \/>\nper Unit<\/strong><\/th>\n<td class=\"heading center middle\"><strong>External<br \/>\nconnection<\/strong><\/td>\n<th class=\"heading center middle\"><strong>5 V<\/strong><\/th>\n<td class=\"heading center middle\"><strong>24 V<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Interrupt<br \/>\nInput Unit<\/strong><\/p>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/tab\/family\/1642\/img\/cj1w-int01_lu_1_1.gif\" \/><\/div>\n<\/th>\n<td class=\"left middle\">16 inputs<\/td>\n<td class=\"left middle\">24 VDC,<br \/>\n7 mA<\/td>\n<td class=\"left middle\">16 points,<br \/>\n1 common<\/td>\n<td class=\"left middle\">ON time:<br \/>\n0.05 ms max.<br \/>\nOFF time:<br \/>\n0.5 ms max.<\/td>\n<td class=\"center middle\">2<\/td>\n<td class=\"left middle\">Removable<br \/>\nterminal block<\/td>\n<td class=\"center middle\">0.08<\/td>\n<td class=\"center middle\">&#8212;<\/td>\n<td class=\"left middle\"><strong>CJ1W-INT01<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>Note: 1. Can be used only on CPU Racks, and not on Expansion Racks.<br \/>\n2. The locations where the Units can be mounted depend on the CPU Rack and the CPU Unit model.<br \/>\nCJ2H-CPU6[]-EIP: From the slot next to the CPU Unit until the fourth slot.<br \/>\nCJ1G, CJ1H: From the slot next to the CPU Unit until the fifth slot.<br \/>\nCJ1M: From the slot next to the CPU Unit until the third slot.<br \/>\n3. With the SYSMAC NJ-series Controllers,Interrupt Input Units can be used as normal Basic Input Units. They<br \/>\ncannot be used to start I\/O interrupt tasks.<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-B02\">Accessories<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>There is no accessory for the CJ series Interrupt Input Units.<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h4 class=\"heading-A02\">CJ1W-INT01 Interrupt Input Unit (16 Points)<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading left middle\"><strong>Name<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">16-point Interrupt Input Unit with Terminal Block<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Model<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">CJ1W-INT01<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Rated Input Voltage<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">24 VDC<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Rated Input Voltage Range<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">20.4 to 26.4 VDC<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Input Impedance<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">3.3 k\u03a9<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Input Current<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">7 mA typical (at 24 VDC)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>ON Voltage\/ON Current<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">14.4 VDC min.\/3 mA min.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>OFF Voltage\/OFF Current<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">5 VDC max.\/1 mA max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>ON Response Time<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">0.05 ms max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>OFF Response Time<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">0.5 ms max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of Circuits<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">16 (16 points\/common, 1 circuit)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of Simultaneously<br \/>\nON Points<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">100% (16 points\/common) simultaneously ON (24 VDC)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Insulation Resistance<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">20 M\u03a9 between external terminals and GR terminal (at 100 VDC)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>DielectrQic Strength<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">1,000 VAC between external terminals and GR terminal for 1 minute at a leakage current of 10 mA max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Internal Current<br \/>\nConsumption<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">80 mA max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Weight<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">110 g max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Accessories<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">None<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Circuit Configuration<\/strong><\/th>\n<td class=\"left middle\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/tab\/family\/1642\/img\/1642_sp_1_1.gif\" \/><\/p>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/tab\/family\/1642\/img\/1642_sp_1_2.gif\" \/><\/div>\n<\/div>\n<\/td>\n<td class=\"left middle\">Up to two Interrupt Input Units can be mounted to the<br \/>\nCPU Rack. They must be connected as one of the five<br \/>\nUnits immediately next to the CPU Unit. If an Interrupt<br \/>\nInput Unit is connected in any other position, an Incorrect<br \/>\nUnit\/Expansion Rack Connection error will occur.<br \/>\nSet the pulse width of signals input to the Interrupt Input<br \/>\nUnit so they satisfy the following conditions.<br \/>\nThe signal names of the terminals are the device variable<br \/>\nnames.<br \/>\nThe device variable names are the names that use &#8220;Jxx&#8221;<br \/>\nas the device name.<\/p>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/tab\/family\/1642\/img\/1642_sp_1_3.gif\" \/><\/div>\n<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>External connection and<br \/>\nterminal-device variable<br \/>\ndiagram<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/tab\/family\/1642\/img\/1642_sp_1_4.gif\" \/><br \/>\nThe polarity can be connected in either direction.<br \/>\nThe signal names of the terminals are the device variable names. The device variable names are the names<br \/>\nthat use &#8220;Jxx&#8221; as the device name.<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>Note: With NJ-series Controllers, Interrupt Input Units can be used as normal Basic Input Units.<br \/>\nThey cannot be used to start I\/O interrupt tasks.<br \/>\n* Terminal numbers A0 to A8 and B0 to B8 are used in the external connection and terminal-device variable diagrams.<br \/>\nThey are not printed on the Units.<\/div>\n<\/div>\n<\/div>\n<div><\/div>\n<div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>(Unit: mm)<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-B02\">CJ1W-INT01<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/cj1w-idp01_dm_113-106645.gif\" alt=\"CJ1W-INT01 Dimensions 2 CJ1W-INT01_Dim\" \/><\/div>\n<\/div>\n<\/div>\n<div><\/div>\n<div><\/div>\n<div>\n<table id=\"global_data\" class=\"tableA01 tablesorter\" border=\"1\" cellspacing=\"0\">\n<thead>\n<tr class=\"tablesorter-header\">\n<th class=\"dl_name\">\n<div class=\"tablesorter-header-inner\">Catalog Name<\/div>\n<\/th>\n<th class=\"dl_cat_number\">\n<div class=\"tablesorter-header-inner\">Catalog Number<br \/>\n[size]<\/div>\n<\/th>\n<th class=\"dl_date tablesorter-header\">\n<div class=\"tablesorter-header-inner\">Last Update<\/div>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"odd first-child\">\n<td><a href=\"http:\/\/www.ia.omron.com\/data_pdf\/cat\/cj1w-int01_ds_csm1615.pdf?id=1642\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" class=\"iconD01\" src=\"http:\/\/www.ia.omron.com\/resources\/images\/icon_pdf.gif\" alt=\"\" width=\"11\" height=\"12\" \/>\u00a0CJ1W-INT01 Data Sheet<\/a><\/td>\n<td>&#8211;<br \/>\n<span class=\"file-size\">[511KB]<\/span><\/td>\n<td class=\"td_date\">Nov 14, 2011<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h2 class=\"heading-B02\">High-speed Starting of I\/O Interrupt Tasks. Use Up to Two Units for a Total of Up to 32 Interrupt Inputs. This unit is available for CJ\/NJ controller.<\/h2>\n","protected":false},"featured_media":1426,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[91,63,72],"product_tag":[],"_links":{"self":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product\/1571"}],"collection":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/comments?post=1571"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/media\/1426"}],"wp:attachment":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/media?parent=1571"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=1571"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=1571"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}