{"id":1510,"date":"2019-01-03T02:48:00","date_gmt":"2019-01-03T02:48:00","guid":{"rendered":"http:\/\/al-tet-onlinesales.allyoulovetrading.com\/?post_type=product&#038;p=1510"},"modified":"2019-01-03T02:48:00","modified_gmt":"2019-01-03T02:48:00","slug":"cj1m-cpu1-etn","status":"publish","type":"product","link":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/product\/cj1m-cpu1-etn\/","title":{"rendered":"CJ1M-CPU1[]-ETN"},"content":{"rendered":"<p>\u2022 Compact 90 \u00d7 65 mm (H \u00d7 D) dimensions are first class in the industry.<\/p>\n<p>\u2022 SYSMAC CJ-series CPU Unit with the functionality of an Ethernet Unit.<\/p>\n<p>\u2022 The CPU functional element has the same functionality as a CJ1M-CPU11\/12\/13. The enables effective usage of legacy applications.<\/p>\n<p>\u2022 High-capacity Memory Cards up to 128 MB can be installed, and used to backup the program and system settings, or log customer data.<\/p>\n<p>\u2022 The large instruction set can support diverse applications. Four types of programming are supported (ladder, structured text, sequential function charts, and instruction lists), with approximately 400 instructions and 800 instruction variations.<\/p>\n<p>\u2022 These CJ-series CPU Units support structured programming using function blocks, which can improve the customer&#8217;s program development resources.<\/p>\n<p>\u2022 The various protection functions provide improved security to protect valuable software resources and property.<\/p>\n<p>\u2022 The CPU Units are compatible with the CX-One Integrated Tool Package. Information for each component can be linked, and the system&#8217;s data can be integrated into one database. The software can provide total support from PLC settings to network startup.<\/p>\n<p>&nbsp;<\/p>\n<h4 class=\"heading-B02\">Applicable standards<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Ask your OMRON representative for the most recent applicable standards for each model.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"2\"><strong>Product name<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"5\" rowspan=\"1\"><strong>Specifications<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Current<br \/>\nconsump-<br \/>\ntion (A)<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>I\/O capacity\/<br \/>\nMountable Units<br \/>\n(Expansion<br \/>\nRacks)<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Pro-<br \/>\ngram<br \/>\nca-<br \/>\npacity<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Data<br \/>\nmemory<br \/>\ncapacity<\/strong><\/th>\n<th class=\"heading center middle\"><strong>LD in-<br \/>\nstruction<br \/>\nexecution<br \/>\ntime<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Eth-<br \/>\nernet<br \/>\nfunc-<br \/>\ntion<\/strong><\/th>\n<th class=\"heading center middle\"><strong>5 V<\/strong><\/th>\n<th class=\"heading center middle\"><strong>24 V<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><strong>CJ1M<br \/>\nCPU<br \/>\nUnits<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><strong>Ethernet<br \/>\nfunction<br \/>\n<img title=\"2000_lu_1_1\" src=\"http:\/\/www.ia.omron.com\/Images\/2000_lu_1_113-288708.gif\" alt=\"2000_lu_1_1\" \/><\/strong><\/th>\n<td class=\"left middle\">640 points\/20 Units<br \/>\n(1 Expansion Racks<br \/>\nmax.)<\/td>\n<td class=\"left middle\">20K<br \/>\nsteps<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"3\">32K words<br \/>\n(DM: 32K<br \/>\nwords,<br \/>\nEM: None)<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"3\">0.1 \u03bcs<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"3\">YES<br \/>\n*1<\/td>\n<td class=\"center middle\">0.95<br \/>\n*2<\/td>\n<td class=\"center middle\">&#8211;<\/td>\n<td class=\"left middle\"><strong>CJ1M-CPU13-ETN<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">320 points\/10 Units<br \/>\n(No Expansion Rack)<\/td>\n<td class=\"left middle\">10K<br \/>\nsteps<\/td>\n<td class=\"center middle\">0.95<br \/>\n*2<\/td>\n<td class=\"center middle\">&#8211;<\/td>\n<td class=\"left middle\"><strong>CJ1M-CPU12-ETN<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">160 points\/10 Units<br \/>\n(No Expansion Rack)<\/td>\n<td class=\"left middle\">5K<br \/>\nsteps<\/td>\n<td class=\"center middle\">0.95<br \/>\n*2<\/td>\n<td class=\"center middle\">&#8211;<\/td>\n<td class=\"left middle\"><strong>CJ1M-CPU11-ETN<br \/>\n*3<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>*1. Ethernet function<br \/>\nThe Ethernet functional element provides the main functions of the CJ1W-ETN21 Ethernet Unit.<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading center middle\"><strong>Physical layer<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Maximum number of nodes in FINS network<\/strong><\/td>\n<th class=\"heading center middle\"><strong>Communications service<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\">100BASE-TX, 10BASE-T<\/td>\n<td class=\"center middle\">254<\/td>\n<td class=\"left middle\">FINS communications service<br \/>\nFTP server<br \/>\nAutomatically adjusted clock information.<br \/>\nWeb functions<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Socket services and sending\/receiving mail are not supported.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>*2. Current consumptions include current for a Programming Console. Add 0.15 A per Adapter when using NT-AL001<br \/>\nRS-232C\/RS-232A Adapters.<br \/>\nAdd 0.04 A per Adapter when using CJ1W-CIF11 RS-422A Adapters.<br \/>\n*3. The CJ1M low-end models (CJ1M-CPU11(-ETN)\/CPU21) have different specifications for the overhead processing<br \/>\ntime, number of subroutines, number of jumps, and number of scheduled interrupts than the other CJ1M models<br \/>\n(CJ1M-CPU12(-ETN)\/CPU13(-ETN)\/CPU22\/CPU23).<br \/>\nFor details, refer to the SYSMAC CJ-series Operation Manual (Cat. No. W474).<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Accessories<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>The following accessories come with CPU Unit:<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading center middle\"><strong>Item<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Specification<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Battery<\/strong><\/th>\n<td class=\"left middle\">CJ1W-BAT01<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>End Cover<\/strong><\/th>\n<td class=\"left middle\">CJ1W-TER01 (necessary to be mouned at the right end of CPU Rack)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>End Plate<\/strong><\/th>\n<td class=\"left middle\">PFP-M (2 pcs)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Serial Port (RS-232C) Connector<\/strong><\/th>\n<td class=\"left middle\">Connector set for serial port connection (D-SUB 9-pin male connector)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h4 class=\"heading-A02\">Common Specifications<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Item<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"3\" rowspan=\"1\"><strong>Specifications<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Control method<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Stored program<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>I\/O control method<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Cyclic scan and immediate processing are both possible.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Programming Languages<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Ladder Logic (LD), Sequential Function Charts (SFC), Structured Text (ST), and<br \/>\nMnemonic.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>CPU processing mode<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Normal Mode or Peripheral Servicing Priority Mode<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Instruction length<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">1 to 7 steps per instruction<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Ladder instructions<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Approx. 400 (3-digit function codes)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Execution<br \/>\ntime<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Basic instructions<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">0.10 \u03bcs min.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Special<br \/>\ninstructions<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">0.15 \u03bcs min.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Overhead time<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">CJ1M-CPU12-ETN\/CPU13-ETN: 0.5 ms min.<br \/>\nCJ1M-CPU11-ETN: 0.7 ms min.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Unit connection method<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">No Backplane: Units connected directly to each other.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Mounting method<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">DIN Track (screw mounting not possible)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Maximum number of<br \/>\nconnectable Units<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Total of 19 Units, including 9 Units on CPU Rack and 10 Units on one Expansion<br \/>\nRack.<br \/>\n(The built-in Ethernet port on the CPU Unit must be allocated to a slots 0, and is<br \/>\ncounted as one Unit.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Maximum number of Expansion<br \/>\nRacks<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">CJ1M-CPU13-ETN: 1 max. (An I\/O Control Unit is required on the CPU Rack and<br \/>\nan I\/O Interface Unit is required on the Expansion Rack.)<br \/>\nCJ1M-CPU11-ETN\/12-ETN: Expansion is not possible.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Number of tasks<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">288 (cyclic tasks: 32, interrupt tasks: 256)<br \/>\nWith CJ1-H or CJ1M CPU Units, interrupt tasks can be defined as cyclic tasks<br \/>\ncalled extra cyclic tasks. Including these, up to 288 cyclic tasks can be used.<br \/>\nCyclic tasks are executed each cycle and are controlled with TKON (820) and<br \/>\nTKOF (821) instructions.<br \/>\nNote 1.<br \/>\nThe following 4 types of interrupt tasks are supported.<br \/>\nNote 2.<br \/>\nPower OFF interrupt tasks: 1 max.<br \/>\nScheduled interrupt tasks: 2 max.<br \/>\nI\/O interrupt tasks: 32 max.<br \/>\nExternal interrupt tasks: 256 max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Interrupt types<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Scheduled Interrupts: Interrupts generated at a time scheduled by the CPU Units<br \/>\nbuilt-in timer.<br \/>\nI\/O Interrupts: Interrupts from Interrupt Input Units.<br \/>\nPower OFF Interrupts (See note): Interrupts executed when the CPU Units power<br \/>\nis turned OFF.<br \/>\nExternal I\/O Interrupts: Interrupts from the Special I\/O Units or CPU Bus Units.<br \/>\nNote: Not supported when the CJ1W-PD022 Power Supply Unit is mounted.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Calling subroutines from more<br \/>\nthan one task<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Supported (called global subroutines).<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"14\"><strong>CIO<br \/>\n(Core I\/O)<br \/>\nArea<\/strong><\/th>\n<th class=\"heading left middle\"><strong>I\/O Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">2,560: CIO 000000 to CIO 015915 (160 words from CIO 0000 to<br \/>\nCIO 0159)<br \/>\nThe setting of the first word can be changed from the default (CIO<br \/>\n0000) so that CIO 0000 to CIO 0999 can be used.<br \/>\nI\/O bits are allocated to Basic I\/O Units.<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"13\">The CIO Area<br \/>\ncan be used<br \/>\nas work bits<br \/>\nif the bits are<br \/>\nnot used as<br \/>\nshown here.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Link Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">3,200 (200 words): CIO 10000 to CIO 119915 (words CIO 1000 to<br \/>\nCIO 1199)<br \/>\nLink bits are used for data links and are allocated to Units in<br \/>\nController Link Systems.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>CPU Bus Unit Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">6,400 (400 words): CIO 150000 to CIO 189915 (words CIO 1500 to<br \/>\nCIO 1899)<br \/>\nCPU Bus Unit bits store the operating status of CPU Bus Units.<br \/>\n(25 words per Unit, 16 Units max.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Special I\/O Unit<br \/>\nArea<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">15,360 (960 words): CIO 200000 to CIO 295915 (words CIO 2000<br \/>\nto CIO 2959)<br \/>\nSpecial I\/O Unit bits are allocated to Special I\/O Units. (10 words<br \/>\nper Unit, 96 Units max.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Serial PLC Link<br \/>\nArea (CJ1M CPU<br \/>\nUnits only)<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">1,440 (90 words): CIO 310000 to CIO 318915 (words CIO 3100 to<br \/>\nCIO 3189)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"8\"><strong>DeviceNet Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">9,600 (600 words): CIO 320000 to CIO 379915 (words CIO 3200 to<br \/>\nCIO 3799)<br \/>\nDeviceNet bits are allocated to Slaves for DeviceNet Unit remote<br \/>\nI\/O communications when the Master function is used with fixed<br \/>\nallocations.<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Fixed allocation setting 1<\/td>\n<td class=\"left middle\">Outputs: CIO 3200 to CIO 3263<br \/>\nInputs: CIO 3300 to CIO 3363<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Fixed allocation setting 2<\/td>\n<td class=\"left middle\">Outputs: CIO 3400 to CIO 3463<br \/>\nInputs: CIO 3500 to CIO 3563<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Fixed allocation setting 3<\/td>\n<td class=\"left middle\">Outputs: CIO 3600 to CIO 3663<br \/>\nInputs: CIO 3700 to CIO 3763<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">The following words are allocated to the Master function even<br \/>\nwhen the DeviceNet Unit is used as a Slave.<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Fixed allocation setting 1<\/td>\n<td class=\"left middle\">Outputs: CIO 3370 (Slave to Master)<br \/>\nInputs: CIO 3270 (Master to Slave)<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Fixed allocation setting 2<\/td>\n<td class=\"left middle\">Outputs: CIO 3570 (Slave to Master)<br \/>\nInputs: CIO 3470 (Master to Slave)<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Fixed allocation setting 3<\/td>\n<td class=\"left middle\">Outputs: CIO 3770 (Slave to Master)<br \/>\nInputs: CIO 3670 (Master to Slave)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Internal I\/O Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">4,800 bits (300 words): CIO 120000 to CIO 149915 (words CIO 1200 to CIO 1499)<br \/>\n37,504 (2,344 words): CIO 380000 to CIO 614315 (words CIO 3800 CIO 6143)<br \/>\nThese bits in the CIO Area are used as work bits in programming to control<br \/>\nprogram execution. They cannot be used for external I\/O.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Work Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">8,192 bits (512 words): W00000 to W51115 (W000 to W511)<br \/>\nControls the programs only. (I\/O from external I\/O terminals is not possible.)<br \/>\nNote: When using work bits in programming, use the bits in the Work Area first<br \/>\nbefore using bits from other areas.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Holding Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">8,192 bits (512 words): H00000 to H51115 (H000 to H511) Holding bits are used to<br \/>\ncontrol the execution of the program, and maintain their ON\/OFF status when the<br \/>\nPLC is turned OFF or the operating mode is changed.<br \/>\nNote: The Function Block Holding Area words are allocated from H512 to H1535.<br \/>\nThese words can be used only for the function block instance area (internally<br \/>\nallocated variable area).<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Auxiliary Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Read only: 7,168 bits (448 words): A00000 to A44715 (words A000 to A447)<br \/>\nRead\/write: 8,192 bits (512 words): A44800 to A95915 (words A448 to A959)<br \/>\nAuxiliary bits are allocated specific functions.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Temporary Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">16 bits (TR0 to TR15)<br \/>\nTemporary bits are used to temporarily store the ON\/OFF execution conditions at<br \/>\nprogram branches.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Timer Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">4,096: T0000 to T4095 (used for timers only)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Counter Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">4,096: C0000 to C4095 (used for counters only)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>DM Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">32 Kwords: D00000 to D32767<br \/>\nUsed as a general-purpose data area for reading and writing data in word units (16<br \/>\nbits). Words in the DM Area maintain their status when the PLC is turned OFF or<br \/>\nthe operating mode is changed.<br \/>\nInternal Special I\/O Unit DM Area: D20000 to D29599 (100 words \u00d7 96 Units)<br \/>\nUsed to set parameters for Special I\/O Units.<br \/>\nCPU Bus Unit DM Area: D30000 to D31599 (100 words \u00d7 16 Units)<br \/>\nUsed to set parameters for CPU Bus Units.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>EM Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">None<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Index Registers<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">IR0 to IR15<br \/>\nStore PLC memory addresses for indirect addressing. Index registers can be used<br \/>\nindependently in each task.<br \/>\nOne register is 32 bits (2 words).<br \/>\nSetting to use index registers either independently in each task or to share them<br \/>\nbetween tasks.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Task Flag Area<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">32 (TK0000 to TK0031)<br \/>\nTask Flags are read-only flags that are ON when the corresponding cyclic task is<br \/>\nexecutable and OFF when the corresponding task is not executable or in standby<br \/>\nstatus.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Trace Memory<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">4,000 words (trace data: 31 bits, 6 words)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>File Memory<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Memory Cards: Compact flash memory cards can be used (MS-DOS format).<br \/>\nOMRON Memory Cards can be used.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"40\"><strong>Function<br \/>\nSpecifi-<br \/>\ncations<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Constant cycle<br \/>\ntime<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">1 to 32,000 ms (Unit: 1 ms)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Cycle time<br \/>\nmonitoring<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Possible (Unit stops operating if the cycle is too long): 10 to 40,000 ms (Unit: 10<br \/>\nms)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>I\/O refreshing<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Cyclic refreshing, immediate refreshing, refreshing by IORF (097).<br \/>\nNote: ORF (097) refreshes I\/O bits allocated to Basic I\/O Units and Special I\/O<br \/>\nUnits.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Timing of special<br \/>\nrefreshing for CPU<br \/>\nBus Units<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Data links for Controller Link Units remote I\/O for DeviceNet Units, and other<br \/>\nspecial refreshing for CPU Bus Units is performed at the following times:<br \/>\nI\/O refresh period and when the CPU BUS UNIT I\/O REFRESH (DLNK (226))<br \/>\ninstruction is executed.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>I\/O memory holding<br \/>\nwhen changing<br \/>\noperating modes<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Depends on the ON\/OFF status of the IOM Hold Bit in the Auxiliary Area.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Load OFF<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">All outputs on Output Units can be turned OFF when the CPU Unit is operating in<br \/>\nRUN, MONITOR, or PROGRAM mode.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Timer\/Counter PV<br \/>\nrefresh method<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">BCD or binary (CX-Programmer Ver. 3.0 or higher).<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Input response<br \/>\ntime setting<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Time constants can be set for inputs from Basic I\/O Units.<br \/>\nThe time constant can be increased to reduce the influence of noise and<br \/>\nchattering or it can be decreased to detect shorter pulses on the inputs.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Mode setting at<br \/>\npower-up<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Possible.<br \/>\nNote: By default, the CPU Unit will start in RUN mode if a Programming Console is<br \/>\nnot connected.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Flash memory<br \/>\n(CJ1-H and CJ1M<br \/>\nCPU Units only)<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">The user program and parameter area data (e.g., PLC Setup) are always backed up<br \/>\nautomatically in flash memory. (automatic backup and restore.)<br \/>\nCPU Units with unit version 3.0 or later only:<br \/>\nWhen downloading projects from CX-Programmer Ver. 5.0 or higher, symbol table<br \/>\nfiles (including CX-Programmer symbol names, I\/O comments), comment files<br \/>\n(CX-Programmer rung comments, other comments), and program index files (CX-<br \/>\nProgrammer section names, section comments, or program comments) are stored<br \/>\nin comment memory within the flash memory.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"4\"><strong>Memory Card<br \/>\nfunctions<\/strong><\/th>\n<td class=\"left middle\">Automatically reading<br \/>\nprograms (autoboot) from<br \/>\nthe Memory Card when the<br \/>\npower is turned ON.<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Possible.<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Program replacement<br \/>\nduring PLC operation<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Possible.<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Format in which data is<br \/>\nstored in Memory Card<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">User program: Program file format PLC Setup and<br \/>\nother parameters: Data file format I\/O memory: Data<br \/>\nfile format (binary format), text format, or CSV format<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Functions for which<br \/>\nMemory Card read\/write is<br \/>\nsupported<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">User program instructions, Programming Devices<br \/>\n(including CX-Programmer and Programming<br \/>\nConsoles), Host Link computers, AR Area control<br \/>\nbits, easy backup operation<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Filing<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Memory Card data and the EM (Extended Data Memory) Area can be handled as<br \/>\nfiles.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Debugging<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Control set\/reset, differential monitoring, data tracing (scheduled, each cycle, or<br \/>\nwhen instruction is executed), instruction error tracing, storing location<br \/>\ngenerating error when a program error occurs.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Online editing<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">User programs can be overwritten in program-block units when the CPU Unit is in<br \/>\nMONITOR or PROGRAM mode.<br \/>\nThis function is not available for block programming areas.<br \/>\nWith the CX-Programmer, more than one program block can be edited at the same<br \/>\ntime.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Program<br \/>\nprotection<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Overwrite protection: Set using DIP switch.<br \/>\nCopy protection: Password set using CX-Programmer or Programming Consoles.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Error check<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">User-defined errors (i.e., user can define fatal errors and non-fatal errors)<br \/>\nThe FPD(269) instruction can be used to check the execution time and logic of<br \/>\neach programming block.<br \/>\nNote: FAL and FALS instructions can be used with the CJ1-H and CJ1M CPU<br \/>\nUnits to simulate errors.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Error log<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Up to 20 errors are stored in the error log. Information includes the error code,<br \/>\nerror details, and the time the error occurred.<br \/>\nNote: CJ1M CPU Unit can be set so that user-defined FAL errors are not stored<br \/>\nin the error log.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Serial<br \/>\ncommunications<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Built-in peripheral port: Programming Device (including Programming Console)<br \/>\nconnections, Host Links, NT Links, Serial Gateway (CompoWay\/F master)<br \/>\nBuilt-in RS-232C port: Programming Device (excluding Programming Console)<br \/>\nconnections, Host Links, no-protocol communications, NT Links, Modbus-RTU<br \/>\nSlave, Serial Gateway (CompoWay\/F master or Modbus master)<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Serial Communications Unit (sold separately): Protocol macros, Host Links, NT<br \/>\nLinks<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"6\"><strong>Clock<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Provided on all models.<br \/>\nAccuracy:<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Ambient temperature<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Monthly error<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">55\u00b0C<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">-3.5 min to +0.5 min<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">25\u00b0C<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">-1.5 min to +1.5 min<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">0\u00b0C<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">-3 min to +1 min<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Note: Used to store the time when power is turned ON and when errors occur.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Power OFF<br \/>\ndetection time<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">AC Power Supply Unit: 10 to 25 ms (not fixed)<br \/>\nDC Power Supply Unit PD025: 2 to 5 ms; PD022: 2 to 10 ms<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Power OFF<br \/>\ndetection delay<br \/>\ntime<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">0 to 10 ms (user-defined, default: 0 ms)<br \/>\nNote: Not supported when the CJ1W-PD022 Power Supply Unit is mounted.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Memory protection<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Held Areas: Holding bits, contents of Data Memory and Extended Data Memory, and<br \/>\nstatus of the counter Completion Flags and present values.<br \/>\nNote:<br \/>\nIf the IOM Hold Bit in the Auxiliary Area is turned ON, and the PLC Setup is set to<br \/>\nmaintain the IOM Hold Bit status when power to the PLC is turned ON, the<br \/>\ncontents of the CIO Area, the Work Area, part of the Auxiliary Area, timer<br \/>\nCompletion Flag and PVs, Index Registers, and the Data Registers will be saved for<br \/>\nup to 20 days.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Sending<br \/>\ncommands to a<br \/>\nHost Link<br \/>\ncomputer<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">FINS commands can be sent to a computer connected via the Host Link System<br \/>\nby executing Network Communications Instructions from the PLC.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Remote<br \/>\nprogramming and<br \/>\nmonitoring<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Host Link communications can be used for remote programming and remote<br \/>\nmonitoring through a Controller Link System or Ethernet network.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Communicating<br \/>\nacross<br \/>\nnetwork levels<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Remote programming and monitoring from Support Software and FINS message<br \/>\ncommunications can be performed across different network levels, even for<br \/>\ndifferent types of network.<br \/>\nPre-Ver. 2.0: Three levels<br \/>\nVersion 2.0 or later: Eight levels for Controller Link and Ethernet networks (See<br \/>\nnote.), three levels for other networks.<br \/>\nNote: To communicate across eight levels, the CX-Integrator or the CX-Net in<br \/>\nProgrammer version 4.0 or higher must be used to set the routing tables.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Storing comments<br \/>\nin CPU Unit<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">I\/O comments can be stored as symbol table files in the Memory Card, EM file<br \/>\nmemory, or comment memory (see note).<br \/>\nNote: Comment memory is supported for CX-Programmer version 5.0 or higher<br \/>\nand CS\/CJ-series CPU Units with unit version 3.0 or later only.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Program check<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Program checks are performed at the beginning of operation for items such as no<br \/>\nEND instruction and instruction errors.<br \/>\nCX-Programmer can also be used to check programs.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Control output<br \/>\nsignals<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">RUN output: The internal contacts will turn ON (close) while the CPU Unit is<br \/>\noperating (CJ1W-PA205R).<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Battery life<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Battery Set for CJ1M CPU Units: CJ1W-BAT01<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Self-diagnostics<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">CPU errors (watchdog timer), I\/O bus errors, memory errors, and battery errors.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Other functions<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Storage of number of times power has been interrupted. (Stored in A514.)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Ethernet Functional Element Transfer Specifications<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading right middle\" colspan=\"2\" rowspan=\"1\"><strong>Item<\/strong><\/th>\n<td class=\"heading center middle\" colspan=\"3\" rowspan=\"1\"><strong>Specifications<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Model<\/strong><\/th>\n<td class=\"heading center middle\"><strong>CJ1M-CPU11-ETN<\/strong><\/td>\n<th class=\"heading center middle\"><strong>CJ1M-CPU12-ETN<\/strong><\/th>\n<td class=\"heading center middle\"><strong>CJ1M-CPU13-ETN<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Media access method<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">CSMA\/CD<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Modulation method<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Baseband<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Transmission paths<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Star form<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Baud rate<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">100 Mbit\/s (100Base-TX), 10 Mbit\/s (10Base-T)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Transmission media<\/strong><\/th>\n<td class=\"heading left middle\"><strong>100 Mbit\/s<\/strong><\/td>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Unshielded twisted-pair (UDP) cable Categories: 5, 5e<br \/>\nShielded twisted-pair (STP) cable Categories: 100 \u03a9 at 5, 5e<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>10 Mbit\/s<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Unshielded twisted-pair (UDP) cable Categories: 3, 4, 5, 5e<br \/>\nShielded twisted-pair (STP) cable Categories: 100 \u03a9 at 3, 4, 5, 5e<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Transmission distance<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">100 m (distance between hub and node)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Number of cascade connections<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">There are no restrictions with the use of switching hubs.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>CPU Bus Unit System Setup Area capacity<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">994 bytes<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Note: The system settings for Ethernet are in the CPU Bus Unit System Setup Area in the CPU Unit.<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>(Unit: mm)<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-B02\">CJ1M CPU Unit (with Ethernet function)<br \/>\nCJ1M-CPU11-ETN\/CPU12-ETN\/CPU13-ETN<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/2000_dm_113-108519.gif\" alt=\"CJ1M-CPU1[]-ETN Dimensions 1 \" \/><\/div>\n<\/div>\n<div><\/div>\n<div><\/div>\n<div>\n<div class=\"inner-contents-area\">\n<div class=\"primary-contents-area\">\n<div class=\"tabpanel-blockA01\">\n<div class=\"editable-block\">\n<div class=\"table-blockA01\">\n<table id=\"global_data\" class=\"tableA01 tablesorter\" border=\"1\" cellspacing=\"0\">\n<thead>\n<tr class=\"tablesorter-header\">\n<th class=\"dl_name\">\n<div class=\"tablesorter-header-inner\">Catalog Name<\/div>\n<\/th>\n<th class=\"dl_cat_number\">\n<div class=\"tablesorter-header-inner\">Catalog Number<br \/>\n[size]<\/div>\n<\/th>\n<th class=\"dl_date tablesorter-header\">\n<div class=\"tablesorter-header-inner\">Last Update<\/div>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"odd first-child\">\n<td><a href=\"http:\/\/www.ia.omron.com\/data_pdf\/cat\/cj1m-cpu-etn_ds_e_2_3_csm1794.pdf?id=2000\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" class=\"iconD01\" src=\"http:\/\/www.ia.omron.com\/resources\/images\/icon_pdf.gif\" alt=\"\" width=\"11\" height=\"12\" \/>\u00a0CJ1M-CPU1[]-ETN Data Sheet<\/a><\/td>\n<td>&#8211;<br \/>\n<span class=\"file-size\">[630KB]<\/span><\/td>\n<td class=\"td_date\">Dec 03, 2018<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"local-navi-area\">\n<div class=\"local-navi-area\">\n<div class=\"local-naviA01\">\n<h2 class=\"heading-link\"><\/h2>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h2 class=\"heading-B02\">A Micro CJ1M CPU Unit with Built-in Ethernet Newly Released!<\/h2>\n","protected":false},"featured_media":1508,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[90,63,72],"product_tag":[],"_links":{"self":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product\/1510"}],"collection":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/comments?post=1510"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/media\/1508"}],"wp:attachment":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/media?parent=1510"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=1510"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=1510"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}