{"id":1489,"date":"2019-01-03T00:47:51","date_gmt":"2019-01-03T00:47:51","guid":{"rendered":"http:\/\/al-tet-onlinesales.allyoulovetrading.com\/?post_type=product&#038;p=1489"},"modified":"2019-01-03T00:47:51","modified_gmt":"2019-01-03T00:47:51","slug":"cs1w-clk","status":"publish","type":"product","link":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/product\/cs1w-clk\/","title":{"rendered":"CS1W-CLK"},"content":{"rendered":"<p>\u2022 Large-capacity data links are easily achieved without programming simply by setting data link tables.<\/p>\n<p>\u2022 Up to 20,000 *1 send\/receive words can be set per node for Units (up to 62,000 words for Boards).<\/p>\n<p>\u2022 Data links can be performed with up to 4,000 *2 words per node while ensuring data concurrency.<\/p>\n<p>\u2022 User-set data link tables can be changed while data links are operating. *3<\/p>\n<p>\u2022 Errors for the entire system can be monitored by using error diagnosis support software and a variety of status flags.<\/p>\n<p>\u2022 With the token ring mode of Optical Ring Controller Link Units\/Boards, duplex communications paths enable communications to continue normally even if the cable becomes disconnected.<\/p>\n<p>\u2022 Detecting locations of disconnection greatly shortens time required for maintenance.<\/p>\n<p>\u2022 Installing Controller Link Units in a CS1D system enables Duplex Communications Units to further enhance reliability. *4<\/p>\n<p>*1. Supported for unit version 1.2 or later.<\/p>\n<p>*2. CS1W-CLK[]3 and 3G8F7-CLK[]3 are supported.<\/p>\n<p>*3. Supported for CS1W-CLK[]3, 3G8F7-CLK[]3, and models ending with &#8220;-V1&#8221; (CS1W-CLK12-V1 *5 and CS1W-CLK52-V1*5 with lot numbers 0306[][]_[][][] or later ).<\/p>\n<p>*4. Supported for CS1W-CLK13\/CLK12-V1 *5\/CLK53\/CLK52-V1 *5 and CS1D Duplex and Simplex Systems.<\/p>\n<p>*5. Discontinuation models in July 2012.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h4 class=\"heading-A02\">Controller Link Units<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Unit<br \/>\nclas-<br \/>\nsifica-<br \/>\ntion<\/strong><\/th>\n<td class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Product<br \/>\nname<\/strong><\/td>\n<th class=\"heading center middle\" colspan=\"4\" rowspan=\"1\"><strong>Specifications<\/strong><\/th>\n<td class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>No. of<br \/>\nunit<br \/>\nnumbers<br \/>\nallocated<\/strong><\/td>\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Current<br \/>\nconsump-<br \/>\ntion (A)<\/strong><\/th>\n<td class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/td>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Stand-<br \/>\nards<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Communi-<br \/>\ncations<br \/>\ncable<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Communi-<br \/>\ncations<br \/>\ntype<\/strong><\/td>\n<th class=\"heading center middle\"><strong>Duplex<br \/>\nsupport<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Max. Units<br \/>\nmountable<br \/>\nper CPU<br \/>\nUnit<\/strong><\/td>\n<th class=\"heading center middle\"><strong>5 V<br \/>\nDC<\/strong><\/th>\n<td class=\"heading center middle\"><strong>26 V<br \/>\nDC<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><strong>CS1<br \/>\nCPU<br \/>\nBus<br \/>\nUnit<\/strong><\/th>\n<td class=\"heading left middle\"><strong>Controller<br \/>\nLink Unit<\/strong><\/p>\n<div class=\"image\"><strong><img title=\"1681_lu_1_1\" src=\"http:\/\/www.ia.omron.com\/Images\/1681_lu_1_113-247356.gif\" alt=\"1681_lu_1_1\" \/><\/strong><\/div>\n<\/td>\n<td class=\"left middle\">Wired shielded<br \/>\ntwisted-pair<br \/>\ncable *1<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"3\">Data links<br \/>\nand<br \/>\nmessage<br \/>\nservice<\/td>\n<td class=\"center middle\">No<\/td>\n<td class=\"center middle\">8<\/td>\n<td class=\"center middle\">1<\/td>\n<td class=\"center middle\">0.33<\/td>\n<td class=\"center middle\">&#8211;<\/td>\n<td class=\"left middle\"><strong>CS1W-CLK23<\/strong><\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"3\">UC1, N,<br \/>\nL, CE<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Controller<br \/>\nLink Unit<\/strong><\/p>\n<div class=\"image\"><strong><img title=\"1681_lu_1_2\" src=\"http:\/\/www.ia.omron.com\/Images\/1681_lu_1_213-247357.gif\" alt=\"1681_lu_1_2\" \/><\/strong><\/div>\n<\/th>\n<td class=\"left middle\">Optical ring<br \/>\nH-PCF<br \/>\ncable *2<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">Yes. Unit<br \/>\nduplexing<br \/>\nand cable<br \/>\nloop back<br \/>\nare<br \/>\nsupported.<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">Non-duplex: 8,<br \/>\nDuplex: 11<br \/>\n(6 Units<br \/>\ncomprising 3<br \/>\nsets of Duplex<br \/>\nUnits + 5<br \/>\nNon-duplex<br \/>\nUnits)<\/td>\n<td class=\"center middle\">1<\/td>\n<td class=\"center middle\">0.52<\/td>\n<td class=\"center middle\">&#8211;<\/td>\n<td class=\"left middle\"><strong>CS1W-CLK13<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Controller<br \/>\nLink Unit<\/strong><\/p>\n<div class=\"image\"><strong><img title=\"1681_lu_1_3\" src=\"http:\/\/www.ia.omron.com\/Images\/1681_lu_1_313-247358.gif\" alt=\"1681_lu_1_3\" \/><\/strong><\/div>\n<\/th>\n<td class=\"left middle\">Optical ring<br \/>\nGI cable *3<\/td>\n<td class=\"center middle\">1<\/td>\n<td class=\"center middle\">0.65<\/td>\n<td class=\"center middle\">&#8211;<\/td>\n<td class=\"left middle\"><strong>CS1W-CLK53<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>*1. Use the following special cable for shielded, twisted-pair cable.<br \/>\n\u2022 ESVC0.5\u00d72C-13262 (Bando Electric Wire: Japanese Company)<br \/>\n\u2022 ESNC0.5\u00d72C-99-087B (JMACS Japan Co., Ltd. : Japanese Company)<br \/>\n\u2022 ESPC 1P\u00d70.5mm2 (Nagaoka Electric Wire Co.,Ltd.: Japanese Company)<br \/>\n\u2022 Li2Y-FCY2\u00d70.56qmm (Kromberg &amp; Schubert, Komtec Department: German Company)<br \/>\n\u2022 1\u00d72\u00d7AWG-20PE+Tr.CUSN+PVC (Draka Cables Industrial: Spanish Company)<br \/>\n\u2022 #9207 (Belden: US Company)<br \/>\n*2. When using a wire-to-optical (H-PCF) cable, use a H-PCF cable (for both Controller Link and SYSMAC LINK) or a<br \/>\nH-PCF optical fiber cable with connector.<br \/>\n*3. When using a wire-to-optical (GI) cable, use a GI optical cable that matches the specifications.<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Accessories<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>The Optical Fiber Cable Bracket is included in CS1W-CLK13 and CS1W-CLK53.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Controller Link Support Boards<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Product name<\/strong><\/th>\n<td class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Specifications<\/strong><\/td>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Accessories<\/strong><\/th>\n<td class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/td>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Standards<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Communications<br \/>\ncable<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Communications<br \/>\ntype<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><strong>Controller Link<br \/>\nSupport Board<br \/>\nfor PCI Bus<\/strong><\/p>\n<div class=\"image\"><strong><img title=\"1681_lu_2_1\" src=\"http:\/\/www.ia.omron.com\/Images\/1681_lu_2_113-247359.gif\" alt=\"1681_lu_2_1\" \/><\/strong><\/div>\n<\/th>\n<td class=\"left middle\">Wired shielded<br \/>\ntwisted-pair cable<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"3\">Data links and<br \/>\nmessage service<\/td>\n<td class=\"left middle\">CD-ROM x 1 *<br \/>\nINSTALLATION GUIDE (W467) x 1<br \/>\nCommunications connector x 1<\/td>\n<td class=\"left middle\"><strong>3G8F7-CLK23-E<\/strong><\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"3\">CE<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">H-PCF optical model<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">CD-ROM \u00d7 1 *<br \/>\nINSTALLATION GUIDE (W467) x 1<br \/>\nOptical Fiber Cable Bracket x 1<br \/>\nPower supply connector x 1<\/td>\n<td class=\"left middle\"><strong>3G8F7-CLK13-E<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">GI optical model<\/td>\n<td class=\"left middle\"><strong>3G8F7-CLK53-E<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>* The CD-ROM contains the following software.<br \/>\n\u2022 Controller Link (PCI) Driver<br \/>\n\u2022 FinsGataway Version 2003 (PCI-CLK Edition)<br \/>\n\u2022 FinsGataway Version 3 (PCI-CLK Edition)<br \/>\n\u2022 Setup Diagnostic Utility<br \/>\n\u2022 C Library<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Repeater Units<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading center middle\"><strong>Name<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Specifications<\/strong><\/td>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Standards<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><strong>Controller Link<br \/>\nRepeater Unit<\/strong><\/p>\n<div class=\"image\"><strong><img title=\"1681_lu_3_1\" src=\"http:\/\/www.ia.omron.com\/Images\/1681_lu_3_113-247348.gif\" alt=\"1681_lu_3_1\" \/><\/strong><\/div>\n<\/th>\n<td class=\"left middle\">Wire-to-Wire Model<\/td>\n<td class=\"left middle\"><strong>CS1W-RPT01<\/strong><\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"3\">UC1, CE<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Wire-to-Optical (H-PCF) Model *1<\/td>\n<td class=\"left middle\"><strong>CS1W-RPT02<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Wire-to-Optical (GI) Model *2<\/td>\n<td class=\"left middle\"><strong>CS1W-RPT03<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>Using Repeater Units enables T-branches and long-distance wiring for Wired Controller Link networks, 62-node configurations,\u00a0and converting part of the network to optical cable.<br \/>\nNote: 1. When using wire-to-optical (H-PCF) cable, use a H-PCF cable (for both Controller Link and SYSMAC LINK) or a<br \/>\nH-PCF optical fiber cable with connector.<br \/>\n2. When using wire-to-optical (GI) cable, use a GI optical cable (for Controller Link).<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Relay Terminal Block<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading center middle\"><strong>Name<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Specifications<\/strong><\/td>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Standards<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Relay Terminal Blocks for<br \/>\nWired Controller Link Units<\/strong><\/p>\n<div class=\"image\"><strong><img title=\"1681_lu_4_1\" src=\"http:\/\/www.ia.omron.com\/Images\/1681_lu_4_113-247349.gif\" alt=\"1681_lu_4_1\" \/><\/strong><\/div>\n<\/th>\n<td class=\"left middle\">Used for Wired Controller Link Units (set of 5)<\/td>\n<td class=\"left middle\"><strong>CJ1W-TB101<\/strong><\/td>\n<td class=\"center middle\">&#8211;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Controller Link Units can be replaced without stopping the communications of the entire network if a Relay Terminal Block is installed in advance on the Unit in a Wired Controller Link network. Relay Terminal Blocks cannot be used on Controller Link Support Boards.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Duplex Optical Fiber Cable (H-PCF Cable)<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading center middle\"><strong>Name<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Application<\/strong><\/td>\n<th class=\"heading center middle\"><strong>Specifications<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Model<\/strong><\/td>\n<th class=\"heading center middle\"><strong>Standards<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Duplex Optical<br \/>\nFiber Cable<\/strong><\/th>\n<td class=\"left middle\">CS1W-CLK13 or<br \/>\nCS1W-CLK12-V1 * in a CS1D system<\/td>\n<td class=\"left middle\">H-PCF cable for connecting Duplex<br \/>\nController Link Units Cable length: 50 cm<\/td>\n<td class=\"left middle\"><strong>CS1D-CN051<\/strong><\/td>\n<td class=\"center middle\">&#8211;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>This cable is used to connect Units in active mode (ACT) and standby mode (STB) in a CS1D Duplex System.<br \/>\n* Discontinuation models in July 2012.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">H-PCF Cables and Optical Connectors<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Name<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Application\/construction<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Specifications<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Standards<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"10\">Optical Fiber Cables<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"10\">Controller<br \/>\nLink,<br \/>\nSYSMAC<br \/>\nLINK,<br \/>\nSYSBUS<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"10\">\n<div class=\"image\"><img title=\"1681_lu_6_1\" src=\"http:\/\/www.ia.omron.com\/Images\/1681_lu_6_113-247350.gif\" alt=\"1681_lu_6_1\" \/><\/div>\n<p>1. Optical fiber<br \/>\nsingle-core cord<br \/>\n2. Tension member<br \/>\n(plastic-sheathed wire)<br \/>\n3. Filler (plastic)<br \/>\n4. Filler surrounding<br \/>\nsignal wires (plastic,<br \/>\nyarn, or fiber)<br \/>\n5. Holding tape (plastic)<br \/>\n6. Heat-resistant<br \/>\nPV sheath<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"10\">Two-<br \/>\ncore<br \/>\noptical<br \/>\ncable<br \/>\nwith<br \/>\ntension<br \/>\nmember<\/td>\n<td class=\"left middle\">Black 10 m<\/td>\n<td class=\"left middle\"><strong>S3200-HCCB101<\/strong><\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"12\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Black 50 m<\/td>\n<td class=\"left middle\"><strong>S3200-HCCB501<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Black 100 m<\/td>\n<td class=\"left middle\"><strong>S3200-HCCB102<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Black 500 m<\/td>\n<td class=\"left middle\"><strong>S3200-HCCB502<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Black 1000 m<\/td>\n<td class=\"left middle\"><strong>S3200-HCCB103<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Orange 10 m<\/td>\n<td class=\"left middle\"><strong>S3200-HCCO101<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Orange 50 m<\/td>\n<td class=\"left middle\"><strong>S3200-HCCO501<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Orange 100 m<\/td>\n<td class=\"left middle\"><strong>S3200-HCCO102<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Orange 500 m<\/td>\n<td class=\"left middle\"><strong>S3200-HCCO502<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Orange 1000 m<\/td>\n<td class=\"left middle\"><strong>S3200-HCCO103<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">Optical<br \/>\nConnectors<br \/>\n(Crimp-cut)<\/td>\n<td class=\"center middle\"><img title=\"1681_lu_6_2\" src=\"http:\/\/www.ia.omron.com\/Images\/1681_lu_6_213-247351.gif\" alt=\"1681_lu_6_2\" \/><\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Controller Link:<br \/>\nCS1W-CLK13<br \/>\nCS1W-CLK12-V1 *1<br \/>\n3G8F7-CLK13-E<br \/>\n3G8F7-CLK12-EV1 *1<br \/>\nCS1W-RPT02<br \/>\nSYSMAC LINK:<br \/>\nCS1W-SLK11<br \/>\n3G8F7-SLK11-E<br \/>\nC200HW-SLK13\/14 *1<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Half lock<\/td>\n<td class=\"left middle\"><strong>S3200-COCF2571<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\"><img title=\"1681_lu_6_3\" src=\"http:\/\/www.ia.omron.com\/Images\/1681_lu_6_313-247352.gif\" alt=\"1681_lu_6_3\" \/><\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Controller Link:<br \/>\nCS1W-CLK13<br \/>\nCS1W-CLK12-V1 *1<br \/>\n3G8F7-CLK13-E<br \/>\n3G8F7-CLK12-EV1 *1<br \/>\nCS1W-RPT02<br \/>\nSYSMAC LINK:<br \/>\n3G8F7-SLK11-E<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Full lock<\/td>\n<td class=\"left middle\"><strong>S3200-COCF2071<br \/>\n*2<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>*1. Discontinuation models.<br \/>\n*2. Full-lock Optical Connectors (Crimp-cut) (S3200-COCF2071) cannot be used with the CS1W-SLK11. Use a Half-lock<br \/>\nCable (S3200- COCF2571) or a H-PCF Optical Fiber Cable with Connector (S3200-CN[][][]-[][]-[][]).<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">H-PCF Optical Fiber Cables with Connectors (Black Composite Cables with Two-Optical Lines and Two Power Supply Lines)<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading center middle\"><strong>Application<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Appearance<\/strong><\/td>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Standards<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><strong>Controller Link,<br \/>\nSYSMAC LINK<\/strong><\/th>\n<td class=\"center middle\">\n<div class=\"image\"><img title=\"1681_lu_7_1\" src=\"http:\/\/www.ia.omron.com\/Images\/1681_lu_7_113-247353.gif\" alt=\"1681_lu_7_1\" \/><\/div>\n<\/td>\n<td class=\"left middle\"><strong>S3200-CN[][][]-20-20<\/strong><\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"3\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">\n<div class=\"image\"><img title=\"1681_lu_7_2\" src=\"http:\/\/www.ia.omron.com\/Images\/1681_lu_7_213-247354.gif\" alt=\"1681_lu_7_2\" \/><\/div>\n<\/td>\n<td class=\"left middle\"><strong>S3200-CN[][][]-20-25<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">\n<div class=\"image\"><img title=\"1681_lu_7_3\" src=\"http:\/\/www.ia.omron.com\/Images\/1681_lu_7_313-247355.gif\" alt=\"1681_lu_7_3\" \/><\/div>\n<\/td>\n<td class=\"left middle\"><strong>S3200-CN[][][]-25-25<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Optical connectors for H-PCF Optical Cables with Connectors are adhesive polished.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-B02\">Cable Length<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>The following cable lengths are available: 2 m, 5 m, 15 m, and 20 m. For lengths of 21 m or more, contact your OMRON sales representative.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-B02\">Model Numbers<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/1681_lu_813-119117.gif\" alt=\"CS1W-CLK Lineup 17 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-B02\">Optical Connector Assembly Tool<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading center middle\"><strong>Name<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Applicable Unit<\/strong><\/td>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Manufacturer<\/strong><\/td>\n<th class=\"heading center middle\"><strong>Standards<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Optical Fiber<br \/>\nAssembly Tool *<\/strong><\/th>\n<td class=\"left middle\">This tool is used on site for mounting crimp-cut connectors<br \/>\nand hard plastic-clad silica optical fiber for optical transmission<br \/>\nsystems of SYSMAC C-series SYSBUS, SYSMAC LINK, and<br \/>\nController Link.<\/td>\n<td class=\"left middle\"><strong>CAK-0057<\/strong><\/td>\n<td class=\"left middle\">Sumitomo Electric<br \/>\nIndustries, Ltd.<\/td>\n<td class=\"center middle\">&#8211;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>* There is a risk of quality problems when using cables assembled by typical users, so we recommend purchasing<br \/>\ncables with preattached connectors or having a qualified technician assemble the cables.<\/div>\n<\/div>\n<\/div>\n<div><\/div>\n<div><\/div>\n<div>\n<h4 class=\"heading-A02\">Communications Specifications<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading center middle\"><strong>Items<\/strong><\/th>\n<td class=\"heading center middle\" colspan=\"3\" rowspan=\"1\"><strong>Specifications<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Model<\/strong><\/th>\n<td class=\"left middle\">CS1W-CLK23<br \/>\n3G8F7-CLK23-E<br \/>\nCS1W-CLK21-V1 *1<br \/>\n3G8F7-CLK21-EV1 *1<\/td>\n<td class=\"left middle\">CS1W-CLK13<br \/>\n3G8F7-CLK13-E<br \/>\nCS1W-CLK12-V1 *1<br \/>\n3G8F7-CLK12-EV1 *1<\/td>\n<td class=\"left middle\">CS1W-CLK53<br \/>\n3G8F7-CLK53-E<br \/>\nCS1W-CLK52-V1 *1<br \/>\n3G8F7-CLK52-EV1 *1<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Type<\/strong><\/th>\n<td class=\"left middle\">Wired (shielded twisted-pair cable)<\/td>\n<td class=\"left middle\">Optical Ring (H-PCF cable)<\/td>\n<td class=\"left middle\">Optical Ring (GI cable)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Communications method<\/strong><\/th>\n<td class=\"left middle\">N:N token-bus method<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">N:N token-ring method (token-ring mode)<br \/>\nN:N token-bus method (token-bus mode)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Code<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Manchester code<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Modulation<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Baseband code<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Synchronization<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Flag synchronization (conforms to HDLC frames)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Transmission path format<\/strong><\/th>\n<td class=\"left middle\">Multidrop method (bus type)<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Ring method (token-ring mode)<br \/>\nDaisy-chain method (token-ring mode)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Transmission speed<\/strong><\/th>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">The following are the maximum<br \/>\ntransmission distances depending on<br \/>\nthe transmission speed.<br \/>\n2 Mbits\/s: 500 m<br \/>\n1 Mbits\/s: 800 m<br \/>\n500 kbits\/s: 1 km<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">2 Mbits\/s<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum transmission<br \/>\ndistance<\/strong><\/th>\n<td class=\"left middle\">20 km<\/td>\n<td class=\"left middle\">30 km<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum distance between<br \/>\nnodes<\/strong><\/th>\n<td class=\"left middle\">Not specified. (Maximum transmission<br \/>\ndistance must be satisfied for the<br \/>\nentire system.)<\/td>\n<td class=\"left middle\">Crimp-cut: 800 m<br \/>\nAdhesive polishing: 1 km *2<\/td>\n<td class=\"left middle\">62.5\/125 \u03bcm: 2 km<br \/>\n50\/125 \u03bcm: 1 km<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Medium<\/strong><\/th>\n<td class=\"left middle\">Specified shielded twist-pair cable<br \/>\nTwo signal wires, one shield<\/td>\n<td class=\"left middle\">H-PCF cable<br \/>\n(two-core optical cable)<\/td>\n<td class=\"left middle\">GI cable (two-core optical<br \/>\ncable: 62.5\/125 \u03bcm, 50\/<br \/>\n125 \u03bcm)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Node connection method<\/strong><\/th>\n<td class=\"left middle\">PLC: Connection to terminal block<br \/>\nComputer: Connection using special<br \/>\n(supplied) connector<\/td>\n<td class=\"left middle\">Connection using special<br \/>\nconnector (full-lock connector<br \/>\nor half-lock connector)<\/td>\n<td class=\"left middle\">Connection using ST<br \/>\nconnector<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum number of nodes<\/strong><\/th>\n<td class=\"left middle\">32 or 62 nodes *3 *4<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">62 *5<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Applicable Programming<br \/>\nDevices<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">CX-Integrator in CX-One, CX-Net in CX-Programmer *4, and Programming Console<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Communications functions<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Data links and message service<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of data link words<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Send words per node: 4,000 words max. (CS1W-CLK[]3), 1,000 words max. (All other Units)<br \/>\nNumber of send\/receive words per node:<br \/>\n12,000 words max. (Pre-Ver. 1.2)<br \/>\n20,000 words max. (unit Ver. 1.2 or later)<br \/>\nTotal number of send words per network: 62,000 words max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Data link areas<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">PLC: Bit areas (CIO Area, Work Area, Link Area *6), Data Memory (DM), Extended DM Area (EM)<br \/>\nComputer: FinsGateway event memory<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Message length<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">2,012 bytes max. (including the header)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>RAS functions<\/strong><\/th>\n<td class=\"left middle\">Polling node backup function<br \/>\nSelf-diagnosis function (hardware<br \/>\nchecking at startup)<br \/>\nEchoback test and broadcast test<br \/>\n(using the FINS command)<br \/>\nWatchdog timer<br \/>\nError log function<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Polling node backup function<br \/>\nSelf-diagnosis function (hardware checking at startup)<br \/>\nEchoback test and broadcast test (using the FINS command)<br \/>\nWatchdog timer<br \/>\nError log function<br \/>\nNode bypass function<br \/>\nTransmission path duplication (for ring method in token-ring<br \/>\nmode only)<br \/>\nDisconnect detection and notification (token-ring mode only)<br \/>\nNode connection configuration data reading (for ring method<br \/>\nin token-ring mode only)<br \/>\nDuplex operation of Communications Units *7<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Error control<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Manchester code check<br \/>\nCRC check (CCITT X<sup>16<\/sup>+X<sup>12<\/sup>+X<sup>5<\/sup>+1)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>*1. Discontinuation models in July 2012.<br \/>\n*2. The maximum distance between nodes depends on the processing method for connectors and cables.<br \/>\n*3. With wired models, the maximum number of nodes is 32 if Repeater Units are not used. A Repeater Unit is required<br \/>\nwhen building a network with more than 32 nodes. If a Repeater Unit is used, be sure to use only the following<br \/>\nController Link Units or Boards and set the Wired Network 62 Node Enable Bit in the DM Parameter Area software<br \/>\nswitches at all nodes.<br \/>\nCS1W-CLK23\/CLK21-V1 *1<br \/>\nCJ1W-CLK23\/CLK21-V1 *1<br \/>\n3G8F7-CLK23-E\/CLK21-EV1 *1<br \/>\n*4. CX-Net in CX-Programmer version 3.1 or earlier can be used only in a system with a maximum of 32 nodes (node<br \/>\naddress 1 to 32). If a system is to be used with a maximum of 62 nodes (node addresses 1 to 62), use CX-Net in<br \/>\nCX-Programmer version 3.2 or higher or the CX-Integrator.<br \/>\n*5. If duplex Controller Link Units are used, the effective maximum number of nodes will be 62 (i.e., the maximum<br \/>\nnumber of nodes in standby mode (STB)).<br \/>\n*6. CS-series PLCs do not have a Link Area, but LR000 to LR199 are automatically converted CIO 1000 to CIO 1199.<br \/>\n*7. Only when a CS1W-CLK13\/12-V1 *1\/53\/52-V1 *1 installed in a CS1D system is used in token ring mode.<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Individual Specifications<\/h4>\n<h4 class=\"heading-A03\">Controller Link Units<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Item<\/strong><\/th>\n<td class=\"heading center middle\" colspan=\"3\" rowspan=\"1\"><strong>Specifications<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Model<\/strong><\/th>\n<td class=\"left middle\">CS1W-CLK23<br \/>\nCS1W-CLK21-V1 *<\/td>\n<td class=\"left middle\">CS1W-CLK13<br \/>\nCS1W-CLK12-V1 *<\/td>\n<td class=\"left middle\">CS1W-CLK53<br \/>\nCS1W-CLK52-V1 *<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Supported PLC<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">All CS-series CPU Units<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Number of mountable Units<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Unit version 1.2 or later: 8 Units max., Pre-Ver. 1.2: 4 Units max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Installation site<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Install onto a CPU Backplane or CS-series Expansion Backplane (classified as a CPU Bus Unit).<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Storage location for network parameters<br \/>\nand manually set data tables<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">CPU Bus Unit Area (in the CPU Unit parameter area)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Storage location for routing tables<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">CPU Unit parameter area<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Weight<\/strong><\/th>\n<td class=\"left middle\">220 g<\/td>\n<td class=\"left middle\">300 g<br \/>\n(excluding mounting bracket)<\/td>\n<td class=\"left middle\">300 g<br \/>\n(excluding mounting bracket)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><strong>Current<br \/>\nconsumption<\/strong><\/th>\n<td class=\"heading left middle\"><strong>5 V in PLC<\/strong><\/td>\n<td class=\"left middle\">0.33 A<\/td>\n<td class=\"left middle\">0.52 A<\/td>\n<td class=\"left middle\">0.65 A<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>26 V in PLC<\/strong><\/th>\n<td class=\"center middle\">&#8211;<\/td>\n<td class=\"center middle\">&#8211;<\/td>\n<td class=\"center middle\">&#8211;<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>External 24 V<\/strong><\/th>\n<td class=\"center middle\">&#8211;<\/td>\n<td class=\"left middle\">0.20 A<\/td>\n<td class=\"left middle\">0.26 A<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>* Discontinuation models in July 2012.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Controller Link Support Boards (for PCI Bus)<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Item<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"3\" rowspan=\"1\"><strong>Specifications<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Models<\/strong><\/th>\n<td class=\"left middle\">3G8F7-CLK23-E<\/td>\n<td class=\"left middle\">3G8F7-CLK13-E<\/td>\n<td class=\"left middle\">3G8F7-CLK53-E<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Applicable computers<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">IBM PC\/AT or compatible<br \/>\nCPU: Intel Celeron 400 MHz or better<br \/>\nMain memory: 128 MB minimum<br \/>\nOne or more PCI bus slots (PCI bus revision 2.0 or higher, power supply: 5 V)<br \/>\nAvailable hard disk space: 70 MB min.<br \/>\nCD-ROM drive: One required for installation<br \/>\nDisplay: VGA (640 \u00d7 480 (pixels) min.)<br \/>\n(Other conditions conform to the OS.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Compatible OS<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">FinsGateway Version 2003 *1<br \/>\nWindows 10 (32bit)<br \/>\nWindows 8 (32bit)<br \/>\nWindows 7 (32bit) Professional<br \/>\nWindows 7 (32bit) Home Premium<br \/>\nWindows Vista Business<br \/>\nWindows Vista Home Premium<br \/>\nFinsGateway Version 3 *2<br \/>\nWindows XP Professional<br \/>\nWindows XP Home Edition<br \/>\nWindows 2000 Professional<br \/>\nWindows NT 4.0 (Service Pack 3 or higher)<br \/>\nWindows ME<br \/>\nWindows 98SE<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Weight<\/strong><\/th>\n<td class=\"left middle\">104 g<\/td>\n<td class=\"left middle\">120 g (excluding<br \/>\nmounting bracket)<\/td>\n<td class=\"left middle\">124 g (excluding<br \/>\nmounting bracket)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Current<br \/>\nconsumption<\/strong><\/th>\n<th class=\"heading left middle\"><strong>5 V in PLC<\/strong><\/th>\n<td class=\"left middle\">0.35 A<\/td>\n<td class=\"left middle\">0.54 A<\/td>\n<td class=\"left middle\">0.60 A<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>External 24 V<\/strong><\/th>\n<td class=\"center middle\">&#8211;<\/td>\n<td class=\"left middle\">0.35 A<\/td>\n<td class=\"left middle\">0.35 A<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>*1. Install the software from CD Ver. 3.12 or higher if the operating system is Windows 10 or 8 (32bit).<br \/>\n*2. Install FinsGateway version 3 if the operating system is Windows NT 4.0 (Service pack 3 or higher), Windows ME, or<br \/>\nWindows 98SE. In that case, however, the new functions of Controller Link Support Boards for the PCI Bus cannot<br \/>\nbe used (i.e., automatic data link creation with 1:N allocation, changing data link tables with active data links, 62-<br \/>\nnode setting for wired models, and maximum of 4000 send words).<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Repeater Units<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\"><strong>Item<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"3\" rowspan=\"1\"><strong>Specifications<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Model<\/strong><\/th>\n<td class=\"left middle\">CS1W-RPT01<\/td>\n<td class=\"left middle\">CS1W-RPT02<\/td>\n<td class=\"left middle\">CS1W-RPT03<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Supported Units and Boards<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">All wired Controller Link Units and Boards<br \/>\nNote: If a maximum of 62 nodes is used, models that support 62 nodes must be used.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Transmission path<\/strong><\/th>\n<td class=\"left middle\">Wire-to-wire<\/td>\n<td class=\"left middle\">Wire-to-optical (H-PCF)<\/td>\n<td class=\"left middle\">Wire-to-optical (GI)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Transmission path format<\/strong><\/th>\n<td class=\"left middle\">Multi-drop<br \/>\nTree<\/td>\n<td class=\"left middle\">1:1<\/td>\n<td class=\"left middle\">1:1<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Installation<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Repeater Units are not mounted to the PLC.<br \/>\nThey are mounted separately with screws or on a DIN Track.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Weight<\/strong><\/th>\n<td class=\"left middle\">130 g<\/td>\n<td class=\"left middle\">130 g<br \/>\n(excluding mounting bracket)<\/td>\n<td class=\"left middle\">130 g<br \/>\n(excluding mounting bracket)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Allowable power supply<br \/>\nvoltage range<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">20.4 to 26.4 VDC (24 VDC &#8211; 15 V to +10%)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Current consumption<\/strong><\/th>\n<td class=\"left middle\">0.06 A at 24 VDC<\/td>\n<td class=\"left middle\">0.06 A at 24 VDC<\/td>\n<td class=\"left middle\">0.07 A at 24 VDC<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Inrush current<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">2.5 A max. (24 VDC with rise time of 5 ms)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Repeater Units are used to expand the Controller Link network for wired models. For Wired-to-optical Repeater Units, always use a set of two (1:1). Optical Ring Controller Link Units and Boards cannot be connected to the optical cable section between Repeater Units.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>(Unit: mm)<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-B02\">CS1W-CLK23\/CS1W-CLK21-V1 *<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/1681_dm_113-119114.gif\" alt=\"CS1W-CLK Dimensions 1 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-B02\">CS1W-CLK13\/CS1W-CLK12-V1 *<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/1681_dm_213-119115.gif\" alt=\"CS1W-CLK Dimensions 2 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-B02\">CS1W-CLK53\/CS1W-CLK52-V1 *<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/1681_dm_313-119116.gif\" alt=\"CS1W-CLK Dimensions 3 \" \/><\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Note: The dimensions in parentheses are for the CS1W-CLK53 (including the terminal cover).<br \/>\n* Discontinuation models in July 2012.<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<table id=\"global_data\" class=\"tableA01 tablesorter\" border=\"1\" cellspacing=\"0\">\n<thead>\n<tr class=\"tablesorter-header\">\n<th class=\"dl_name\">\n<div class=\"tablesorter-header-inner\">Catalog Name<\/div>\n<\/th>\n<th class=\"dl_cat_number\">\n<div class=\"tablesorter-header-inner\">Catalog Number<br \/>\n[size]<\/div>\n<\/th>\n<th class=\"dl_date tablesorter-header\">\n<div class=\"tablesorter-header-inner\">Last Update<\/div>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"odd first-child\">\n<td><a href=\"http:\/\/www.ia.omron.com\/data_pdf\/cat\/cs1w-clk_ds_e_5_6_csm1613.pdf?id=1681\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" class=\"iconD01\" src=\"http:\/\/www.ia.omron.com\/resources\/images\/icon_pdf.gif\" alt=\"\" width=\"11\" height=\"12\" \/>\u00a0CS1W-CLK Data Sheet<\/a><\/td>\n<td>&#8211;<br \/>\n<span class=\"file-size\">[1352KB]<\/span><\/td>\n<td class=\"td_date\">Dec 17, 2018<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<h2 class=\"heading-B02\">New Controller Link Units, Now with 4,000 Send Words<\/h2>\n","protected":false},"featured_media":1481,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[92,63,72],"product_tag":[],"_links":{"self":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product\/1489"}],"collection":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/comments?post=1489"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/media\/1481"}],"wp:attachment":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/media?parent=1489"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=1489"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=1489"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}