{"id":1476,"date":"2019-01-03T00:32:44","date_gmt":"2019-01-03T00:32:44","guid":{"rendered":"http:\/\/al-tet-onlinesales.allyoulovetrading.com\/?post_type=product&#038;p=1476"},"modified":"2019-01-03T00:32:50","modified_gmt":"2019-01-03T00:32:50","slug":"cs1w-eip21","status":"publish","type":"product","link":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/product\/cs1w-eip21\/","title":{"rendered":"CS1W-EIP21"},"content":{"rendered":"<h4 class=\"heading-A01\">Global Standard<\/h4>\n<h4 class=\"heading-A02\">Highly Open Global Standard for FA Industry with High Future Potential<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>The ODVA promotes the spread of Industrial Ethernet all over the world.<\/strong><\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>EtherNet\/IP can be used to communicate with many devices from various companies around the world in addition to OMRON components (such as Temperature Controllers and Sensors). The use of EtherNet\/IP will rapidly increase the development of an EtherNet\/IP multivendor environment (including robots and safety devices).<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/1994_fe_113-108476.jpg\" alt=\"CS1W-EIP21 Features 3 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A02\">Integrated Information and Control Network<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>Seamless communications on the control line and information monitoring line with EtherNet\/IP<\/strong><\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Using the global standard open protocol (CIP), an independent network system can be created with seamless data flow between the control line and the information monitoring line.<br \/>\nOMRON FINS message communications can also be used on the same network because it is a standard LAN.<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/1994_fe_213-108478.jpg\" alt=\"CS1W-EIP21 Features 5 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A02\">Improved operation efficiency with common Support Software operation<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>Use the same operating procedures for both EtherNet\/IP and DeviceNet Support Software.<\/strong><\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>The same Support Software procedures can be used from a remote location for device configuration, monitoring, and program transfer for the DeviceNet and EtherNet\/IP networks.<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/1994_fe_313-108479.jpg\" alt=\"CS1W-EIP21 Features 7 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A02\">Monitor Safety Systems<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>Safety systems can be monitored through the EtherNet\/IP.<\/strong><\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>The safety system can be monitored from a PLC by using a modular designed Safety Control Unit with a EtherNet\/IP Coupler Unit.<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/1994_fe_413-119128.jpg\" alt=\"CS1W-EIP21 Features 9 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A01\">Convenience of the Universal Ethernet Right in Your Hands<\/h4>\n<h4 class=\"heading-A02\">Higher Data Link Capacity (9 times the capacity of previous OMRON models)<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>High-capacity communications with high-speed high-capacity bus<\/strong><\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>All types of data, from process interlocks and manufacturing recipes to production data, can be exchanged at high speed and with optimal timing. The ability to communicate is incomparably better than previous networks, such as the Controller Link and FL-net.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/1994_fe_513-108481.jpg\" alt=\"CS1W-EIP21 Features 13 \" \/><\/div>\n<div class=\"text\">\n<p>Note: Using a built-in EtherNet\/IP port on CJ2H and EtherNet\/IP Units.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Low Cost Expansion for Each Line<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>Flexible topology with the Ethernet switch<\/strong><\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Flexible wiring and expansion are possible with Ethernet switches. This means that there will be no total network crashes caused by communications path errors, ensuring high network performance and security.<\/p>\n<p>&#8211; Joining and leaving the network is possible during communications.<\/p>\n<p>Nodes can leave the network during operation, enabling easy maintenance for error detection, separation, and restoration.<\/p>\n<p>&#8211; Unpredictable delays caused by data collisions are minimum.<br \/>\n&#8211; Problems caused by wiring errors are minimized to each line.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/1994_fe_613-108483.jpg\" alt=\"CS1W-EIP21 Features 16 \" \/><\/div>\n<div class=\"text\">\n<p>Star topology using Ethernet switch technology<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Reduced Network Facility and Wiring Costs<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>Generic LAN cables can be used.<\/strong><\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>&#8211; Metal cables of category 5, 5e, or higher can be used as LAN cables.<br \/>\n&#8211; Generic RJ-45 connectors can be used.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Standard wireless LAN can be used because EtherNet\/IP is also Universal Ethernet.<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>There is no need to rewire even when layout has been changed.<\/strong><\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>&#8211; EtherNet\/IP can be made wireless using the standard wireless LAN.<br \/>\n&#8211; High-speed Smart Roaming communications can be used for mobile units with the WE70 FA Wireless LAN. The communications range can be expanded by relaying communications between access points.<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/1994_fe_713-108485.jpg\" alt=\"CS1W-EIP21 Features 20 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A01\">Integration of Control and Information Networks<\/h4>\n<h4 class=\"heading-A02\">High-speed Data Links with Optimal Cycles for Applications (30 times higher than previous OMRON models)<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>Flexible and high-speed cyclic communications<\/strong><\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>&#8211; Grouping can be used in data link tables to create multiple sections.<\/p>\n<p>Data link table can be divided into up to 256 groups (= connections).<br \/>\nThe optimum communications cycle for the application can be set for each group.<\/p>\n<p>&#8211; Cyclic synchronization can be set for each group.<\/p>\n<p>The communications cycle can be set to between 0.5 ms and 10 s in 0.5-ms increments. Data concurrency is maintained for each connection. The communications cycle does not change even if the number of nodes increases. The communications performance is 30 times better than that of the Controller Link.<br \/>\nExample:<br \/>\nData link refresh cycle for 25 linked Unit and 20,000 words\/network is reduced from 300 ms to 10 ms.<\/p>\n<p>&#8211; Facilities can be easily expanded.<\/p>\n<p>When expanding facilities, all you need to do is make additions to the tables. Expansion is possible with little time and low cost.<br \/>\nNote: Using a built-in EtherNet\/IP port on CJ2H and EtherNet\/IP Units.<\/p><\/div>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/1994_fe_813-108488.jpg\" alt=\"CS1W-EIP21 Features 23 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A02\">FTP, Data Links, and Support Software Can Be Used Simultaneously with One Port<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>With the multipurpose EtherNet\/IP port, an Ethernet Unit is not required for expansion.<\/strong><\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Using the multipurpose EtherNet\/IP port built into a CJ\/NJ\/NX\/NY CPU Unit, a single port can be used for data link communications between PLCs, messages between PLCs, and Universal Ethernet communications, such as FTP transfers while connecting Support Software. An EtherNet\/IP Unit can be added to any CS\/CJ-series PLC to achieve the same functions.<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/1994_fe_913-108490.jpg\" alt=\"CS1W-EIP21 Features 25 \" \/><\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/1994_fe_1113-232813.jpg\" alt=\"CS1W-EIP21 Features 26 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-A02\">Memory Map Management Becomes Unnecessary.<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>Freed from memory map by tags<\/strong><\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>The transmission\/reception area can be specified with normal names called tag names instead of addresses for communication on data links between devices or when communication with the host application.<br \/>\nThe efficiency of design, startup, maintenance, and upgrading are improved.<\/p>\n<p>&#8211; PT and host applications can be developed in parallel.<\/p>\n<p>Network symbols defined in CJ\/NJ\/NX\/NY CPU Units can be used as tags when designing the PT screen.<br \/>\nDesign is easy: Just decide on the tag names for the information and control departments.<br \/>\nChanges to allocated addresses is not needed later in development.<\/p>\n<p>&#8211; Easier facility upgrading and maintenance<\/p>\n<p>Even if physical addresses change in the PLC, there is no need to make any changes in the data link settings, in the PT, or in the host application.<\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/1994_fe_1013-108492.jpg\" alt=\"CS1W-EIP21 Features 28 \" \/><\/div>\n<\/div>\n<div><\/div>\n<div><\/div>\n<div>\n<h4 class=\"heading-B02\">International Standards<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<ul class=\"listA01\">\n<li>The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.<\/li>\n<li>Contact your OMRON representative for further details and applicable conditions for these standards.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">EtherNet\/IP Unit<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Unit<br \/>\ntype<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Product<br \/>\nname<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"3\" rowspan=\"1\"><strong>Specifications<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>No. of<br \/>\nunit<br \/>\nnumbers<br \/>\nallocated<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Current<br \/>\nconsump-<br \/>\ntion (A)<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Stand-<br \/>\nards<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Communi-<br \/>\ncations<br \/>\ncable<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Communi-<br \/>\ncations<br \/>\nfunctions<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Units<br \/>\nper<br \/>\nCPU<br \/>\nUnit<\/strong><\/th>\n<th class=\"heading center middle\"><strong>5 V<br \/>\nsys-<br \/>\ntem<\/strong><\/th>\n<th class=\"heading center middle\"><strong>24 V<br \/>\nsys-<br \/>\ntem<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>CS1<br \/>\nCPU<br \/>\nBus<br \/>\nUnit<\/strong><\/th>\n<th class=\"heading left middle\"><strong>EtherNet\/IP<br \/>\nUnit<\/strong><\/p>\n<div class=\"image\"><strong><img title=\"1994_lu_1_1\" src=\"http:\/\/www.ia.omron.com\/Images\/1994_lu_1_113-245420.gif\" alt=\"1994_lu_1_1\" \/><\/strong><\/div>\n<\/th>\n<td class=\"left middle\">Shielded twisted-<br \/>\npair (STP) cable<br \/>\nCategories:<br \/>\n100 \u03a9 at 5, 5e<\/td>\n<td class=\"left middle\">Tag Data Link<br \/>\nFunctions,<br \/>\nMessage<br \/>\nCommunications<br \/>\nFunctions<\/td>\n<td class=\"center middle\">8<br \/>\nmax.<\/td>\n<td class=\"center middle\">1<\/td>\n<td class=\"center middle\">0.41<\/td>\n<td class=\"center middle\">&#8212;<\/td>\n<td class=\"left middle\"><strong>CS1W-EIP21<\/strong><\/td>\n<td class=\"left middle\">UC1,<br \/>\nN, L,<br \/>\nCE<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Industrial Switching Hubs<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Product<br \/>\nname<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Appearance<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"3\" rowspan=\"1\"><strong>Specifications<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Accessories<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Current<br \/>\nconsump-<br \/>\ntion (A)<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Stand-<br \/>\nards<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Functions<\/strong><\/th>\n<th class=\"heading center middle\"><strong>No.<br \/>\nof<br \/>\npors<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Failure<br \/>\ndetec-<br \/>\ntion<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><strong>Industrial<br \/>\nSwitching<br \/>\nHubs<\/strong><\/th>\n<td class=\"center middle\"><img title=\"1994_lu_2_1\" src=\"http:\/\/www.ia.omron.com\/Images\/1994_lu_2_113-245421.gif\" alt=\"1994_lu_2_1\" \/><\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"3\">Quality of Service<br \/>\n(QoS): EtherNet\/IP<br \/>\ncontrol data priority<br \/>\nFailure detection:<br \/>\nBroadcast storm and<br \/>\nLSI error detection<br \/>\n10\/100BASE-TX,<br \/>\nAuto-Negotiation<\/td>\n<td class=\"center middle\">3<\/td>\n<td class=\"center middle\">No<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">Power supply<br \/>\nconnector<\/td>\n<td class=\"center middle\">0.22<\/td>\n<td class=\"left middle\"><strong>W4S1-03B<\/strong><\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">UC, CE<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\"><img title=\"1994_lu_2_2\" src=\"http:\/\/www.ia.omron.com\/Images\/1994_lu_2_213-245422.gif\" alt=\"1994_lu_2_2\" \/><\/td>\n<td class=\"center middle\">5<\/td>\n<td class=\"center middle\">No<\/td>\n<td class=\"center middle\">0.22<\/td>\n<td class=\"left middle\"><strong>W4S1-05B<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">5<\/td>\n<td class=\"center middle\">Yes<\/td>\n<td class=\"left middle\">Power supply<br \/>\nconnector<br \/>\nConnector<br \/>\nfor informing<br \/>\nerror<\/td>\n<td class=\"center middle\">0.22<\/td>\n<td class=\"left middle\"><strong>W4S1-05C<\/strong><\/td>\n<td class=\"left middle\">CE<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h4 class=\"heading-A02\">EtherNet\/IP Unit Specifications<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Item<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Specifications<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Model number<\/strong><\/th>\n<td class=\"left middle\">CS1W-EIP21<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Type<\/strong><\/th>\n<td class=\"left middle\">100Base-TX (See note.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Applicable PLCs<\/strong><\/th>\n<td class=\"left middle\">CS-series PLCs<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Unit classification<\/strong><\/th>\n<td class=\"left middle\">CS-series CPU Bus Unit<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Mounting location<\/strong><\/th>\n<td class=\"left middle\">CPU Rack or Expansion Rack<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Number of Units that can be mounted<\/strong><\/th>\n<td class=\"left middle\">8 max. (including Expansion Racks)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"7\"><strong>CPU Unit<br \/>\nwords used<\/strong><\/th>\n<td class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Allocated CIO Area<br \/>\nwords (CPU Bus Unit<br \/>\nwords)<\/strong><\/td>\n<td class=\"left middle\">25 words\/Unit (one unit number&#8217;s words)<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">These words contain control bits and flags, the target node PLC&#8217;s operating and error<br \/>\ninformation, Unit status, communications status, registered\/normal target node information,<br \/>\nand FINS\/TCP connection status.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Allocated DM Area<br \/>\nwords (CPU Bus Unit<br \/>\nwords)<\/strong><\/th>\n<td class=\"left middle\">100 words\/Unit (one unit number&#8217;s words)<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">These words contain the IP address display\/setting area<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>User-set area<\/strong><\/th>\n<td class=\"left middle\">Any usable data area words<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Target node PLC&#8217;s operating and error information, and registered\/normal target node<br \/>\ninformation<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>CPU Bus Unit System<br \/>\nSetup<\/strong><\/th>\n<td class=\"left middle\">Not used.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Non-volatile memory within<br \/>\nEtherNet\/IP Unit (See note.)<\/strong><\/th>\n<td class=\"left middle\">The following settings are stored in the EtherNet\/IP Unit&#8217;s non-volatile memory.<br \/>\nNote: Unlike the regular Ethernet Units, the CPU Bus Unit Setup Area in the CPU Unit is not<br \/>\nused for these settings.<br \/>\n1. Unit setup (communications settings for the EtherNet\/IP Unit, such as the IP address, DNS<br \/>\nserver settings, host name, baud rate, FINS\/UDP settings, and FINS\/TCP settings)<br \/>\n2. Tag data link settings (device parameters)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"7\"><strong>Transfer<br \/>\nspecifications<\/strong><\/th>\n<td class=\"heading left middle\"><strong>Media access method<\/strong><\/td>\n<td class=\"left middle\">CSMA\/CD<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Modulation method<\/strong><\/th>\n<td class=\"left middle\">Baseband<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Transmission paths<\/strong><\/th>\n<td class=\"left middle\">Star form<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Baud rate<\/strong><\/th>\n<td class=\"left middle\">100 Mbit\/s (100Base-TX)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Transmission media<\/strong><\/th>\n<td class=\"left middle\">Shielded twisted-pair (STP) cable<br \/>\nCategories: 100 \u03a9 at 5, 5e<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Transmission distance<\/strong><\/th>\n<td class=\"left middle\">100 m (distance between hub and node)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of cascade<br \/>\nconnections<\/strong><\/th>\n<td class=\"left middle\">There is no limitation when a switching hub is used.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Current consumption (Unit)<\/strong><\/th>\n<td class=\"left middle\">410 mA max. at 5 V DC<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Weight<\/strong><\/th>\n<td class=\"left middle\">171 g max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Dimensions<\/strong><\/th>\n<td class=\"left middle\">35 \u00d7 130 \u00d7 101 mm (W \u00d7 H \u00d7 D)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Other general specifications<\/strong><\/th>\n<td class=\"left middle\">Other specifications conform to the general specifications of the CS-series<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Note: If tag data links are being used, use 100Base-TX. Otherwise, 10Base-T can be used, but this is not recommended.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Communications Specifications<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"3\" rowspan=\"1\"><strong>Item<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Specifications<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"17\"><strong>CIP<br \/>\nservice<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"14\"><strong>Tag data<br \/>\nlinks<br \/>\n(Cyclic<br \/>\ncommuni-<br \/>\ncations)<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Number of connections<\/strong><\/th>\n<td class=\"left middle\">256<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Packet interval<br \/>\n(refresh cycle)<\/strong><\/th>\n<td class=\"left middle\">0.5 to 10,000 ms (in 0.5-ms units)<br \/>\nCan be set independently for each connection.<br \/>\n(Data is refreshed over the network at the preset interval and<br \/>\ndoes not depend on the number of nodes.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum allowed<br \/>\ncommunications<br \/>\nbandwidth per Unit<\/strong><\/th>\n<td class=\"left middle\">6,000 to 12,000 pps *1 *2<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of tag sets<\/strong><\/th>\n<td class=\"left middle\">256<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Tag types<\/strong><\/th>\n<td class=\"left middle\">CIO Area, DM Area, EM Area, Holding Area, and Work Area<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of tags per<br \/>\nconnection (= 1 tag set)<\/strong><\/th>\n<td class=\"left middle\">8 (7 tags when the tag set contains the PLC status)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum link data size<br \/>\nper node<\/strong><\/th>\n<td class=\"left middle\">184,832 words<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum data size per<br \/>\nconnection<\/strong><\/th>\n<td class=\"left middle\">252 words or 722 words *3<br \/>\nNote: Data synchronicity is maintained within each connection.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of registrable<br \/>\ntag sets<\/strong><\/th>\n<td class=\"left middle\">256<br \/>\n(1 connection = 1 tag set)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum size of 1 tag<br \/>\nset<\/strong><\/th>\n<td class=\"left middle\">722 words<br \/>\n(The PLC status uses 1 word when the tag set contains the PLC<br \/>\nstatus.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum number of<br \/>\ntags that can be<br \/>\nrefreshed per CPU Unit<br \/>\ncycle *4<\/strong><\/th>\n<td class=\"left middle\">Output\/Transmission (CPU to EtherNet\/IP): 19<br \/>\nInput\/Reception (EtherNet\/IP to CPU): 20 *5<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Data that can be<br \/>\nrefreshed per CPU Unit<br \/>\ncycle *4<\/strong><\/th>\n<td class=\"left middle\">Output\/Transmission (CPU to EtherNet\/IP): 7,405 words<br \/>\nInput\/Reception (EtherNet\/IP to CPU): 7,405 words<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Changing tag data link<br \/>\nparameters during<br \/>\noperation<\/strong><\/th>\n<td class=\"left middle\">Supported *6<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Multicast packet filter<br \/>\nfunction *7<\/strong><\/th>\n<td class=\"left middle\">Supported<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><strong>Explicit<br \/>\nmessaging<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Class 3 (connected)<\/strong><\/th>\n<td class=\"left middle\">Number of connections: 128<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>UCMM (unconnected)<\/strong><\/th>\n<td class=\"left middle\">Number of clients that can communicate at one time: 32 max.<br \/>\nNumber of servers that can communicate at one time: 32 max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>CIP routing<\/strong><\/th>\n<td class=\"left middle\">CS1W-EIP21, CJ1W-EIP21, CJ2H-CPU6[]-EIP, CJ2M-CPU3[]<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"2\"><strong>FINS service<\/strong><\/th>\n<th class=\"heading left middle\"><strong>FINS\/UDP<\/strong><\/th>\n<td class=\"left middle\">Supported<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>FINS\/TCP<\/strong><\/th>\n<td class=\"left middle\">16 connections max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>EtherNet\/IP conformance test<\/strong><\/th>\n<td class=\"left middle\">Conforms to A5<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Ethernet interface<\/strong><\/th>\n<td class=\"left middle\">10BASE-T or 100BASE-TX<br \/>\nAuto Negotiation or fixed settings<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>*1. In this case, pps means &#8220;packets per second&#8221; and indicates the number of packets that can be processed in one<br \/>\nsecond.<br \/>\n*2. To use 505 to 1,444 bytes as the data size, the system must support the Large Forward Open standard (an optional<br \/>\nCIP specification). The CS\/CJ-series Units support this standard, but before connecting to nodes of other companies,<br \/>\nconfirm that those devices also support it.<br \/>\n*3. If the maximum data size is exceeded, the data refreshing with the CPU Unit will extend over two or more cycles.<br \/>\n*4. If status layout is selected in the user settings, the maximum number of tags that can be received is 19 tags.<br \/>\n*5. If parameters are changed in the EtherNet\/IP Unit, however, the EtherNet\/IP Unit will be restarted. When other nodes<br \/>\nare communicating with the affected node, the communications will temporarily time out and automatically recover<br \/>\nlater.<br \/>\n*6. Because the EtherNet\/IP Unit is equipped with an IGMP client, unnecessary multicast packets can be filtered by using<br \/>\na switching hub that supports IGMP snooping.<br \/>\n*7. The EtherNet\/IP Unit uses the TCP\/UDP port numbers shown in the following table.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading center middle\"><strong>Service<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Protocol<\/strong><\/td>\n<th class=\"heading center middle\"><strong>Port number<\/strong><\/th>\n<td class=\"heading center middle\"><strong>Remarks<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Tag data links<\/td>\n<td class=\"left middle\">UDP<\/td>\n<td class=\"left middle\">2222<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"3\">Fixed value<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Class 3, UCMM<\/td>\n<td class=\"left middle\">TCP\/UDP<\/td>\n<td class=\"left middle\">44818<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">DNS<\/td>\n<td class=\"left middle\">UDP<\/td>\n<td class=\"left middle\">53<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">FINS\/UDP service<\/td>\n<td class=\"left middle\">UDP<\/td>\n<td class=\"left middle\">9600<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"6\">Port numbers in the Unit Setup can be changed with<br \/>\nthe CX-Programmer.<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">FINS\/TCP service<\/td>\n<td class=\"left middle\">TCP<\/td>\n<td class=\"left middle\">9600<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">FTP<\/td>\n<td class=\"left middle\">TCP<\/td>\n<td class=\"left middle\">20, 21<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">SNTP<\/td>\n<td class=\"left middle\">UDP<\/td>\n<td class=\"left middle\">123<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">SNMP<\/td>\n<td class=\"left middle\">UDP<\/td>\n<td class=\"left middle\">161<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">SNMP trap<\/td>\n<td class=\"left middle\">UDP<\/td>\n<td class=\"left middle\">162<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Network Configurator Requirements<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>The Network Configurator Ver. 3.0 or higher is a software package designed for building, setting, and controlling a multi-vendor EtherNet\/IP Network using OMRON&#8217;s EtherNet\/IP. It is included in CX-One. The Network Configurator provides the following functions for building, setting, and controlling EtherNet\/IP.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Item<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Specification<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Operating environment<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">CXONE-AL[][]D-V[]<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><strong>Network<br \/>\nconnection<br \/>\nmethod<\/strong><\/th>\n<th class=\"heading left middle\"><\/th>\n<th class=\"heading left middle\"><strong>CS1\/CJ1<\/strong><\/th>\n<th class=\"heading left middle\"><strong>CJ2<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Serial interface<\/strong><\/th>\n<td class=\"left middle\">CPU Unit&#8217;s Peripheral or RS-232C port<\/td>\n<td class=\"left middle\">CPU Unit&#8217;s USB or RS-232C port<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Ethernet interface<\/strong><\/th>\n<td class=\"left middle\">EtherNet\/IP Unit&#8217;s Ethernet port<\/td>\n<td class=\"left middle\">CPU Unit&#8217;s Ethernet port<br \/>\nEtherNet\/IP Unit&#8217;s Ethernet port<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Location on Network<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">A single node address is used (only when directly connected to EtherNet\/IP).<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Number of Units that can be<br \/>\nconnected to Network<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">A single Network Configurator per Network<br \/>\n(More than one Configurator cannot be used in the same system.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Main<br \/>\nfunctions<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Network control<br \/>\nfunctions<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">The Network configuration can be created and edited regardless of whether the<br \/>\nNetwork Configurator is online or offline.<br \/>\nThe Network configuration can be read from a file or the network.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Configuration<br \/>\nfunctions<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">The EDS files used by the Network Configurator can be installed and deleted.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Supported file formats<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Configurator network configuration files (*.ncf)<br \/>\nConfiguration files (*.ncf) created using the Network Configurator for EtherNet\/IP<br \/>\n(version 2) can be imported by selecting External Data &#8211; Import from the File Menu.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>(Unit: mm)<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-B02\">CS1W-EIP21<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/cs1w-eip21_dm_113-108494.jpg\" alt=\"CS1W-EIP21 Dimensions 1 \" \/><\/div>\n<\/div>\n<div><\/div>\n<div><\/div>\n<div>\n<div class=\"inner-contents-area\">\n<div class=\"primary-contents-area\">\n<div class=\"tabpanel-blockA01\">\n<div class=\"editable-block\">\n<div class=\"table-blockA01\">\n<table id=\"global_data\" class=\"tableA01 tablesorter\" border=\"1\" cellspacing=\"0\">\n<thead>\n<tr class=\"tablesorter-header\">\n<th class=\"dl_name\">\n<div class=\"tablesorter-header-inner\">Catalog Name<\/div>\n<\/th>\n<th class=\"dl_cat_number\">\n<div class=\"tablesorter-header-inner\">Catalog Number<br \/>\n[size]<\/div>\n<\/th>\n<th class=\"dl_date tablesorter-header\">\n<div class=\"tablesorter-header-inner\">Last Update<\/div>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"odd first-child\">\n<td><a href=\"http:\/\/www.ia.omron.com\/data_pdf\/cat\/cs1w-eip21_ds_e_7_3_csm1782.pdf?id=1994\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" class=\"iconD01\" src=\"http:\/\/www.ia.omron.com\/resources\/images\/icon_pdf.gif\" alt=\"\" width=\"11\" height=\"12\" \/>\u00a0CS1W-EIP21 Data Sheet<\/a><\/td>\n<td>&#8211;<br \/>\n<span class=\"file-size\">[652KB]<\/span><\/td>\n<td class=\"td_date\">Apr 03, 2017<\/td>\n<\/tr>\n<tr class=\"even\">\n<td><a href=\"http:\/\/www.ia.omron.com\/data_pdf\/cat\/cj1w_r150-e1_24_3_csm1003777.pdf?id=1994\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" class=\"iconD01\" src=\"http:\/\/www.ia.omron.com\/resources\/images\/icon_pdf.gif\" alt=\"\" width=\"11\" height=\"12\" \/>\u00a0EtherNet\/IP\u2122 Catalog<\/a><\/td>\n<td>R150-E1-16<br \/>\n<span class=\"file-size\">[2968KB]<\/span><\/td>\n<td class=\"td_date\">Sep 03, 2018<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"local-navi-area\">\n<div class=\"local-navi-area\">\n<div class=\"local-naviA01\">\n<h2 class=\"heading-link\"><\/h2>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h2 class=\"heading-B02\">Introducing the New EtherNet\/IP Unit. More Than 180,000 Words of Tag Data Link Capacity!<\/h2>\n","protected":false},"featured_media":1482,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[92,63],"product_tag":[],"_links":{"self":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product\/1476"}],"collection":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/comments?post=1476"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/media\/1482"}],"wp:attachment":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/media?parent=1476"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=1476"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=1476"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}