{"id":1433,"date":"2019-01-02T08:55:06","date_gmt":"2019-01-02T08:55:06","guid":{"rendered":"http:\/\/al-tet-onlinesales.allyoulovetrading.com\/?post_type=product&#038;p=1433"},"modified":"2019-01-02T08:55:08","modified_gmt":"2019-01-02T08:55:08","slug":"cj1w-idp01","status":"publish","type":"product","link":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/product\/cj1w-idp01\/","title":{"rendered":"CJ1W-IDP01"},"content":{"rendered":"<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>\u2022 A pulse width (ON time) of 0.05 ms min. can be read by the Quick-response Input Unit.<\/p>\n<p>\u2022 Input data read by the internal circuits is cleared when inputs are refreshed.<\/p>\n<p>\u2022 Quick-response Input Units can be used when communicating with inspection equipment to read the many pulse signals that are too short to be read with normal I\/O Units.<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h4 class=\"heading-B02\">International Standards<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<ul class=\"listA01\">\n<li>The standards are abbreviated as follows: U: UL, U1: UL(Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.<\/li>\n<li>Contact your OMRON representative for further details and applicable conditions for these standards.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Quick-response Input Unit<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Unit type: CJ1 Basic I\/O Units<br \/>\nNo. of words allocated: 1 word<br \/>\nStandards: UC1, N, L, CE<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<h4 class=\"heading-A02\">CJ1W-IDP01 Quick-response Input Unit (16 Points)<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th class=\"heading left middle\"><strong>Name<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">16-point Quick-response Input Unit with Terminal Block<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Model<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">CJ1W-IDP01<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Rated Input Voltage<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">24 VDC<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Rated Input Voltage Range<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">20.4 to 26.4 VDC<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Input Impedance<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">3.3 k\u03a9<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Input Current<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">7 mA typical (at 24 VDC)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>ON Voltage\/ON Current<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">14.4 VDC min.\/3 mA min.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>OFF Voltage\/OFF Current<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">5 VDC max.\/1 mA max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>ON Response Time<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">0.05 ms max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>OFF Response Time<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">0.5 ms max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of Circuits<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">16 (16 points\/common, 1 circuit)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of Simultaneously<br \/>\nON Points<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">100% (16 points\/common) simultaneously ON (24 VDC)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Insulation Resistance<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">20 M\u03a9 between external terminals and GR terminal (at 100 VDC)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Dielectric Strength<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">1,000 VAC between external terminals and GR terminal for 1 minute at a leakage current of<br \/>\n10 mA max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Internal Current<br \/>\nConsumption<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">80 mA max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Weight<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">110 g max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Accessories<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">None<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Circuit Configuration<\/strong><\/th>\n<td class=\"left middle\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/tab\/family\/1643\/img\/1643_sp_1_1.gif\" \/><br \/>\nThe signal names of the terminals are the device<br \/>\nvariable names.<br \/>\nThe device variable names are the names that use<br \/>\n&#8220;Jxx&#8221; as the device name.<\/div>\n<\/td>\n<td class=\"left middle\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/tab\/family\/1643\/img\/1643_sp_1_2.gif\" \/><\/div>\n<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>External connection and<br \/>\nterminal-device variable<br \/>\ndiagram<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/tab\/family\/1643\/img\/1643_sp_1_3.gif\" \/><br \/>\nThe input power supply polarity can be connected in either direction.<br \/>\nThe signal names of the terminals are the device variable names.<br \/>\nThe device variable names are the names that use &#8220;Jxx&#8221; as the device name.<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<ul class=\"listA01\">\n<li>With quick-response inputs, pulse inputs shorter than the CPU Unit&#8217;s cycle time can be read by the CPU Unit.<\/li>\n<li>The pulse width (ON time) that can be read by the Quick-response Input Unit is 0.05 ms.<\/li>\n<li>Inputs read by the internal circuits are cleared when inputs are refreshed.<\/li>\n<\/ul>\n<div>* Terminal numbers A0 to A8 and B0 to B8 are used in the external connection and terminal-device variable diagrams.<br \/>\nThey are not printed on the Units.<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div><\/div>\n<div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>(Unit: mm)<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-B02\">8-point\/16-point Units (18-point Terminal Blocks)<br \/>\nCJ1W-IDP01<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/cj1w-idp01_dm_113-106647.gif\" alt=\"CJ1W-IDP01 Dimensions 2 CJ1W-IDP01_Dim\" \/><\/div>\n<\/div>\n<\/div>\n<div><\/div>\n<div><\/div>\n<div>\n<table id=\"global_data\" class=\"tableA01 tablesorter\" border=\"1\" cellspacing=\"0\">\n<thead>\n<tr class=\"tablesorter-header\">\n<th class=\"dl_name\">\n<div class=\"tablesorter-header-inner\">Catalog Name<\/div>\n<\/th>\n<th class=\"dl_cat_number\">\n<div class=\"tablesorter-header-inner\">Catalog Number<br \/>\n[size]<\/div>\n<\/th>\n<th class=\"dl_date tablesorter-header\">\n<div class=\"tablesorter-header-inner\">Last Update<\/div>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"odd first-child\">\n<td><a href=\"http:\/\/www.ia.omron.com\/data_pdf\/cat\/cj1w-idp01_ds_csm1614.pdf?id=1643\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" class=\"iconD01\" src=\"http:\/\/www.ia.omron.com\/resources\/images\/icon_pdf.gif\" alt=\"\" width=\"11\" height=\"12\" \/>\u00a0CJ1W-IDP01 Data Sheet<\/a><\/td>\n<td>&#8211;<br \/>\n<span class=\"file-size\">[499KB]<\/span><\/td>\n<td class=\"td_date\">Nov 29, 2011<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h2 class=\"heading-B02\">Capture Input Signals Shorter Than the Cycle Time. This unit is available for CJ\/NJ controller.<\/h2>\n","protected":false},"featured_media":1425,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[95,63,72],"product_tag":[],"_links":{"self":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product\/1433"}],"collection":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/comments?post=1433"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/media\/1425"}],"wp:attachment":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/media?parent=1433"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=1433"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=1433"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}