{"id":1396,"date":"2019-01-02T03:03:37","date_gmt":"2019-01-02T03:03:37","guid":{"rendered":"http:\/\/al-tet-onlinesales.allyoulovetrading.com\/?post_type=product&#038;p=1396"},"modified":"2019-01-02T03:03:37","modified_gmt":"2019-01-02T03:03:37","slug":"nx-cif-2","status":"publish","type":"product","link":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/product\/nx-cif-2\/","title":{"rendered":"NX-CIF"},"content":{"rendered":"<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>\u2022 Just 12 mm wide, saving space in your cabinet.<\/p>\n<p>\u2022 Three models are available with a choice of one RS-422A\/485, one RS-232C, or two RS-232C ports.<\/p>\n<p>\u2022 Screwless push-in terminal block (1-port model) and D-Sub connector (2-port model) significantly reduce wiring work.<\/p>\n<p>\u2022 No-protocol communications are supported as the communications protocol.<\/p>\n<p>\u2022 The maximum baud rate is 230.4 kbps. The baud rate can be selected to match the connected serial devices.<\/p>\n<p>\u2022 The settings are backed up and saved in the EtherCAT Coupler Unit. This facilitates commissioning and maintenance.<\/p>\n<p>\u2022 The serial line monitor enables you to check the communications status with serial devices on the Sysmac Studio for easy and reliable startup of the devices.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Sysmac is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products.<br \/>\nEtherCAT\u00ae is a registered trademark of Beckhoff Automation GmbH for their patented technology.<br \/>\nEtherNet\/IP<sup>TM<\/sup>\u00a0is the trademarks of ODVA.<br \/>\nOther company names and product names in this document are the trademarks or registered trademarks of their respective companies.<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h4 class=\"heading-B02\">Applicable standards<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Ask your OMRON representative for the most recent applicable standards for each model.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Communications Interface Units<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\"><strong>Product name<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Serial<br \/>\ninterface<\/strong><\/th>\n<th class=\"heading center middle\"><strong>External connection<br \/>\nterminals<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Number of<br \/>\nserial ports<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Communications<br \/>\nprotocol<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><strong>Communications<br \/>\nInterface Unit<br \/>\n<img title=\"3479_lu_1_1\" src=\"http:\/\/www.ia.omron.com\/Images\/3479_lu_1_113-270626.gif\" alt=\"3479_lu_1_1\" \/><\/strong><\/th>\n<td class=\"left middle\">RS-232C<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">Screwless Clamping<br \/>\nTerminal Block<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">1 port<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"3\">No-protocol<br \/>\nSignal lines<\/td>\n<td class=\"left middle\"><strong>NX-CIF101<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">RS-422A\/485<\/td>\n<td class=\"left middle\"><strong>NX-CIF105<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">RS-232C<\/td>\n<td class=\"left middle\">D-Sub connector<\/td>\n<td class=\"left middle\">2 ports<\/td>\n<td class=\"left middle\"><strong>NX-CIF210<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Optional Products<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\"><strong>Product name<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Specification<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Unit\/Terminal Block Coding Pins<\/strong><\/th>\n<td class=\"left middle\">Pins for 10 Units (30 terminal block pins and 30 Unit pins)<\/td>\n<td class=\"left middle\"><strong>NX-AUX02<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Product name<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"4\" rowspan=\"1\"><strong>Specification<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>No. of terminals<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Terminal number<br \/>\nindications<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Ground terminal<br \/>\nmark<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Terminal current<br \/>\ncapacity<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Terminal Block *<\/strong><\/th>\n<td class=\"center middle\">16<\/td>\n<td class=\"center middle\">A\/B<\/td>\n<td class=\"center middle\">Present<\/td>\n<td class=\"center middle\">10 A<\/td>\n<td class=\"left middle\"><strong>NX-TBC162<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>* These options can be used with the NX-CIF101 and NX-CIF105. (They cannot be used with the NX-CIF210.)<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Accessories<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Not included.<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h4 class=\"heading-A02\">General Specification<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Item<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Specification<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Enclosure<\/strong><\/th>\n<td class=\"left middle\">Mounted in a panel.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Grounding method<\/strong><\/th>\n<td class=\"left middle\">Ground of 100 \u03a9 or less.<br \/>\nIf a conductive DIN Track is used, a Communications Interface Units<br \/>\nis grounded through the DIN Track from the System Power Supply<br \/>\nUnit. If a non-conductive DIN Track is used, a Communications<br \/>\nInterface Units is grounded from the FG terminal.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"13\"><strong>Operating<br \/>\nenvironment<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Ambient operating<br \/>\ntemperature<\/strong><\/th>\n<td class=\"left middle\">0 to 55\u00b0C<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Ambient operating<br \/>\nhumidity<\/strong><\/th>\n<td class=\"left middle\">10% to 95% (with no condensation or icing)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Atmosphere<\/strong><\/th>\n<td class=\"left middle\">Must be free from corrosive gases.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Ambient storage<br \/>\ntemperature<\/strong><\/th>\n<td class=\"left middle\">-25 to 70\u00b0C (with no condensation or icing)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Altitude<\/strong><\/th>\n<td class=\"left middle\">2,000 m max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Pollution degree<\/strong><\/th>\n<td class=\"left middle\">2 or less: Conforms to JIS B 3502 and IEC 61131-2.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Noise immunity<\/strong><\/th>\n<td class=\"left middle\">2 kV on power supply line (Conforms to IEC 61000-4-4.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Overvoltage category<\/strong><\/th>\n<td class=\"left middle\">Category II: Conforms to JIS B 3502 and IEC 61131-2.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>EMC immunity level<\/strong><\/th>\n<td class=\"left middle\">Zone B<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Vibration resistance<\/strong><\/th>\n<td class=\"left middle\">Conforms to IEC 60068-2-6.<br \/>\n5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz, Acceleration of<br \/>\n9.8 m\/s<sup>2<\/sup>, 100 min in X, Y, and Z directions (10 sweeps of 10 min<br \/>\neach = 100 min total)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Shock resistance<\/strong><\/th>\n<td class=\"left middle\">Conforms to IEC 60068-2-27. 147 m\/s<sup>2<\/sup>, 3 times each in X, Y, and<br \/>\nZ directions<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Insulation resistance<\/strong><\/th>\n<td class=\"left middle\">20 M\u03a9 min. between isolated circuits (at 100 VDC)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Dielectric strength<\/strong><\/th>\n<td class=\"left middle\">510 VAC between isolated circuits for 1 minute with leakage current<br \/>\nof 5 mA max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Applicable standards *<\/strong><\/th>\n<td class=\"left middle\">cULus: Listed (UL508), ANSI\/ISA 12.12.01, EU: EN 61131-2, NK, LR, RCM,<br \/>\nand KC: KC Registration<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>* Refer to the OMRON website (http:\/\/www.ia.omron.com\/) or consult your OMRON representative for the most recent applicable standards for each model.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Specifications of Individual Units<\/h4>\n<h4 class=\"heading-B02\">NX-CIF101<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Item<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Specification<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Number of ports<\/strong><\/th>\n<td class=\"left middle\">1<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Communications ports<\/strong><\/th>\n<td class=\"left middle\">RS-232C<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Communications protocol<\/strong><\/th>\n<td class=\"left middle\">No-protocol<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"13\"><strong>Communications<br \/>\nspecifications<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Communications method<\/strong><\/th>\n<td class=\"left middle\">Full duplex<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Signal lines *1<\/strong><\/th>\n<td class=\"left middle\">&#8212;<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Baud rate [bps] *1<\/strong><\/th>\n<td class=\"left middle\">1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600,<br \/>\n115,200, or 230,400<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Data length [bits] *1<\/strong><\/th>\n<td class=\"left middle\">7 or 8<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Parity *1<\/strong><\/th>\n<td class=\"left middle\">Even, odd, or none<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Start bits [bits]<\/strong><\/th>\n<td class=\"left middle\">Always 1.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Stop bits [bits] *1<\/strong><\/th>\n<td class=\"left middle\">1 or 2<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Flow control *1<\/strong><\/th>\n<td class=\"left middle\">None, RS\/CS flow control, or Xon\/Xoff control<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Flow control target *1<\/strong><\/th>\n<td class=\"left middle\">Send\/receive, send only, or receive only<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Initial RS signal value *1 *2<\/strong><\/th>\n<td class=\"left middle\">ON or OFF<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of characters to<br \/>\ndetermine the end *1 *3<\/strong><\/th>\n<td class=\"left middle\">0 to 10,000 (in increments of 0.1 character))<br \/>\n0: The end is not detected.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum communications<br \/>\ndistance [m]<\/strong><\/th>\n<td class=\"left middle\">15 *4<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Connection configuration<\/strong><\/th>\n<td class=\"left middle\">1:1<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>I\/O refreshing method<\/strong><\/th>\n<td class=\"left middle\">Free-Run refreshing only<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>PDO data size [bytes] *1<\/strong><\/th>\n<td class=\"left middle\">Inputs or outputs: 4, 8, 12, 16, 20, 24, 28, 32, 36,<br \/>\n40, 44, 48, 52, 56, 60, 64, 68, 72, 76, or 80<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Transmission buffering enable\/disable setting *1<\/strong><\/th>\n<td class=\"left middle\">Enabled or disabled<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Functions to back up data<\/strong><\/th>\n<td class=\"left middle\">Provided. *5<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Terminating resistance setting<\/strong><\/th>\n<td class=\"left middle\">&#8212;<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Isolation method<\/strong><\/th>\n<td class=\"left middle\">No isolation<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Power consumption<\/strong><\/th>\n<td class=\"left middle\">\u2022 Connected to a CPU Unit<br \/>\n1.10 W max.<br \/>\n\u2022 Connected to a Communications Coupler Unit<br \/>\n0.90 W max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Weight<\/strong><\/th>\n<td class=\"left middle\">66 g max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Installation orientation and restrictions<\/strong><\/th>\n<td class=\"left middle\">Installation orientation:<br \/>\n\u2022 Connected to a CPU Unit: Possible in upright installation.<br \/>\n\u2022 Connected to a Communications Coupler Unit:<br \/>\nPossible in 6 orientations.<br \/>\nRestrictions: There are no restrictions.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>*1. Setting is possible in the Unit operation settings of the Sysmac Studio.<br \/>\n*2. This is the value of the RS signal when the port enters the Operational state or immediately after the port is restarted.<br \/>\nThe initial value is disabled when RS\/CS flow control is set.<br \/>\n*3. This setting is provided for communications protocols that assume the end of the data if data is not received for a<br \/>\nspecific period of time. For example, if the number of characters to determine the end is set to 35, the end of the<br \/>\ndata will be assumed if data is not received for the time required to receive 3.5 characters.<br \/>\n*4. If the baud rate is set to higher than 19,200 bps, refer to the manual for the remote communications device.<br \/>\n*5. The settings that are backed up are saved in memory in the Communications Coupler Unit. The settings that are<br \/>\nbacked up are not saved in the Communications Interface Units.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-B02\">NX-CIF105<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Item<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Specification<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Number of ports<\/strong><\/th>\n<td class=\"left middle\">1<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Communications ports<\/strong><\/th>\n<td class=\"left middle\">RS-422A\/485<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Communications protocol<\/strong><\/th>\n<td class=\"left middle\">No-protocol<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"13\"><strong>Communications<br \/>\nspecifications<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Communications method<\/strong><\/th>\n<td class=\"left middle\">Half duplex for two-wire connection, Full duplex for<br \/>\nfour-wire connection<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Signal lines *1<\/strong><\/th>\n<td class=\"left middle\">Two lines or four lines<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Baud rate [bps] *1<\/strong><\/th>\n<td class=\"left middle\">1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600,<br \/>\n115,200, or 230,400<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Data length [bits] *1<\/strong><\/th>\n<td class=\"left middle\">7 or 8<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Parity *1<\/strong><\/th>\n<td class=\"left middle\">Even, odd, or none<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Start bits [bits]<\/strong><\/th>\n<td class=\"left middle\">Always 1.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Stop bits [bits] *1<\/strong><\/th>\n<td class=\"left middle\">1 or 2<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Flow control *1<\/strong><\/th>\n<td class=\"left middle\">None or Xon\/Xoff control<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Flow control target *1<\/strong><\/th>\n<td class=\"left middle\">Send\/receive, send only, or receive only<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Initial RS signal value *1 *2<\/strong><\/th>\n<td class=\"left middle\">ON or OFF<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of characters to<br \/>\ndetermine the end *1 *3<\/strong><\/th>\n<td class=\"left middle\">0 to 10,000 (in increments of 0.1 character))<br \/>\n0: The end is not detected.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum communications<br \/>\ndistance [m]<\/strong><\/th>\n<td class=\"left middle\">1,200 *4<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Connection configuration<\/strong><\/th>\n<td class=\"left middle\">1:N<br \/>\nMaximum value of N is 32.<br \/>\nYou can change between two-wire and four-wire<br \/>\nconnections.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>I\/O refreshing method<\/strong><\/th>\n<td class=\"left middle\">Free-Run refreshing only<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>PDO data size [bytes] *1<\/strong><\/th>\n<td class=\"left middle\">Inputs or outputs: 4, 8, 12, 16, 20, 24, 28, 32, 36,<br \/>\n40, 44, 48, 52, 56, 60, 64, 68, 72, 76, or 80<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Transmission buffering enable\/disable setting *1<\/strong><\/th>\n<td class=\"left middle\">Enabled or disabled<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Functions to back up data<\/strong><\/th>\n<td class=\"left middle\">Provided. *5<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Terminating resistance setting<\/strong><\/th>\n<td class=\"left middle\">Possible<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Isolation method<\/strong><\/th>\n<td class=\"left middle\">Power supply: transformer and photocoupler<br \/>\nSignals: Digital isolators<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Power consumption<\/strong><\/th>\n<td class=\"left middle\">\u2022 Connected to a CPU Unit<br \/>\n1.65 W max.<br \/>\n\u2022 Connected to a Communications Coupler Unit<br \/>\n1.45 W max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Weight<\/strong><\/th>\n<td class=\"left middle\">69 g max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Installation orientation and restrictions<\/strong><\/th>\n<td class=\"left middle\">Installation orientation:<br \/>\n\u2022 Connected to a CPU Unit: Possible in upright installation.<br \/>\n\u2022 Connected to a Communications Coupler Unit:<br \/>\nPossible in 6 orientations.<br \/>\nRestrictions: There are no restrictions.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>*1. Setting is possible in the Unit operation settings of the Sysmac Studio.<br \/>\n*2. This is the value of the RS signal when the port enters the Operational state or immediately after the port is restarted.<br \/>\nThe initial value is disabled when RS\/CS flow control is set. It is also disabled for the NX-CIF105.<br \/>\n*3. This setting is provided for communications protocols that assume the end of the data if data is not received for a<br \/>\nspecific period of time. For example, if the number of characters to determine the end is set to 35, the end of the<br \/>\ndata will be assumed if data is not received for the time required to receive 3.5 characters.<br \/>\n*4. The maximum total cable length for multidrop connections is 1,200 m.<br \/>\n*5. The settings that are backed up are saved in memory in the Communications Coupler Unit. The settings that are<br \/>\nbacked up are not saved in the Communications Interface Units.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-B02\">NX-CIF210<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Item<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Specification<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Number of ports<\/strong><\/th>\n<td class=\"left middle\">2<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Communications ports<\/strong><\/th>\n<td class=\"left middle\">RS-232C<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Communications protocol<\/strong><\/th>\n<td class=\"left middle\">No-protocol<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"13\"><strong>Communications<br \/>\nspecifications<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Communications method<\/strong><\/th>\n<td class=\"left middle\">Full duplex<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Signal lines *1<\/strong><\/th>\n<td class=\"left middle\">&#8212;<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Baud rate [bps] *1<\/strong><\/th>\n<td class=\"left middle\">1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600,<br \/>\n115,200, or 230,400<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Data length [bits] *1<\/strong><\/th>\n<td class=\"left middle\">7 or 8<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Parity *1<\/strong><\/th>\n<td class=\"left middle\">Even, odd, or none<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Start bits [bits]<\/strong><\/th>\n<td class=\"left middle\">Always 1.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Stop bits [bits] *1<\/strong><\/th>\n<td class=\"left middle\">1 or 2<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Flow control *1<\/strong><\/th>\n<td class=\"left middle\">None, RS\/CS flow control, or Xon\/Xoff control<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Flow control target *1<\/strong><\/th>\n<td class=\"left middle\">Send\/receive, send only, or receive only<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Initial RS signal value *1 *2<\/strong><\/th>\n<td class=\"left middle\">ON or OFF<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of characters to<br \/>\ndetermine the end *1 *3<\/strong><\/th>\n<td class=\"left middle\">0 to 10,000 (in increments of 0.1 character))<br \/>\n0: The end is not detected.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum communications<br \/>\ndistance [m]<\/strong><\/th>\n<td class=\"left middle\">15 *4<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Connection configuration<\/strong><\/th>\n<td class=\"left middle\">1:1<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>I\/O refreshing method<\/strong><\/th>\n<td class=\"left middle\">Free-Run refreshing only<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>PDO data size [bytes] *1<\/strong><\/th>\n<td class=\"left middle\">Inputs or outputs: 4, 8, 12, 16, 20, 24, 28, 32, 36,<br \/>\n40, 44, 48, 52, 56, 60, 64, 68, 72, 76, or 80<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Transmission buffering enable\/disable setting *1<\/strong><\/th>\n<td class=\"left middle\">Enabled or disabled<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Functions to back up data<\/strong><\/th>\n<td class=\"left middle\">Provided. *5<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Terminating resistance setting<\/strong><\/th>\n<td class=\"left middle\">&#8212;<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Isolation method<\/strong><\/th>\n<td class=\"left middle\">No isolation<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Power consumption<\/strong><\/th>\n<td class=\"left middle\">\u2022 Connected to a CPU Unit<br \/>\n1.15 W max.<br \/>\n\u2022 Connected to a Communications Coupler Unit<br \/>\n0.95 W max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Weight<\/strong><\/th>\n<td class=\"left middle\">91 g max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Installation orientation and restrictions<\/strong><\/th>\n<td class=\"left middle\">Installation orientation:<br \/>\n\u2022 Connected to a CPU Unit: Possible in upright installation.<br \/>\n\u2022 Connected to a Communications Coupler Unit:<br \/>\nPossible in 6 orientations.<br \/>\nRestrictions: There are no restrictions.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>*1. Setting is possible in the Unit operation settings of the Sysmac Studio.<br \/>\n*2. This is the value of the RS signal when the port enters the Operational state or immediately after the port is restarted.<br \/>\nThe initial value is disabled when RS\/CS flow control is set.<br \/>\n*3. This setting is provided for communications protocols that assume the end of the data if data is not received for a<br \/>\nspecific period of time. For example, if the number of characters to determine the end is set to 35, the end of the<br \/>\ndata will be assumed if data is not received for the time required to receive 3.5 characters.<br \/>\n*4. If the baud rate is set to higher than 19,200 bps, refer to the manual for the remote communications device.<br \/>\n*5. The settings that are backed up are saved in memory in the Communications Coupler Unit. The settings that are<br \/>\nbacked up are not saved in the Communications Interface Units.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Version Information<\/h4>\n<h4 class=\"heading-A03\">Connecting with CPU Units<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Refer to the user&#8217;s manual for the CPU Unit for the CPU Unit to which NX Units can be connected.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>NX Unit<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Corresponding unit versions\/versions<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Unit version<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CPU Unit<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Sysmac Studio<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\">NX-CIF101<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"3\">Ver.1.0<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"3\">Ver.1.13<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"3\">Ver.1.17<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">NX-CIF105<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">NX-CIF210<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>Note: Some Units do not have all of the versions given in the table. If a Unit does not have the specified version, support is<br \/>\nprovided by the oldest available version after the specified version. Refer to the user&#8217;s manuals for the specific Units<br \/>\nfor the relation between models and versions.<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Connecting with an EtherCAT Coupler Unit<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>NX Unit<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"3\" rowspan=\"1\"><strong>Corresponding unit versions\/versions<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Unit version<\/strong><\/th>\n<th class=\"heading center middle\"><strong>EtherCAT Coupler Unit<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CPU Units or Industrial PCs *<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Sysmac Studio<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\">NX-CIF101<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"3\">Ver.1.0<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"3\">Ver.1.0<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"3\">Ver.1.11<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"3\">Ver.1.15<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">NX-CIF105<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">NX-CIF210<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>Note: Some Units do not have all of the versions given in the above table. If a Unit does not have the specified version,<br \/>\nsupport is provided by the oldest available version after the specified version. Refer to the user&#8217;s manuals for the<br \/>\nspecific Units for the relation between models and versions.<br \/>\n* The serial communications instructions for the CIF Units are supported by CPU Units with unit version 1.11 or later. If it is<br \/>\nnot used, it is available for a CPU Unit with unit version 1.10. Refer to the Instructions Reference Manual for the CPU Unit<br \/>\nor Industrial PC for the serial communications instructions for the CIF Units.<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Connecting with an EtherNet\/IP Coupler Unit<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>NX Unit<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"6\" rowspan=\"1\"><strong>Corresponding unit versions\/versions<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Unit<br \/>\nversion<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"3\" rowspan=\"1\"><strong>Application with an NJ\/NX\/NY-series<br \/>\nController *1<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"3\" rowspan=\"1\"><strong>Application with a CS\/CJ\/CP-series PLC<br \/>\n*2<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>EtherNet\/IP<br \/>\nCoupler Unit *3<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CPU Unit or<br \/>\nIndustrial PC<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Sysmac<br \/>\nStudio<\/strong><\/th>\n<th class=\"heading center middle\"><strong>EtherNet\/IP<br \/>\nCoupler Unit *3<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Sysmac<br \/>\nStudio<\/strong><\/th>\n<th class=\"heading center middle\"><strong>NX-IO<br \/>\nConfigurator *4<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\">NX-CIF101<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"3\">Ver.1.0<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"3\">Ver.1.2<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"3\">Ver.1.14<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"3\">Ver.1.19<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"3\">Ver.1.2<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"3\">Ver.1.19<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"3\">Ver.1.00<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">NX-CIF105<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">NX-CIF210<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>Note: Some Units do not have all of the versions given in the above table. If a Unit does not have the specified version,<br \/>\nsupport is provided by the oldest available version after the specified version. Refer to the user&#8217;s manuals for the<br \/>\nspecific Units for the relation between models and versions.<br \/>\n*1 Refer to the user\u2019s manual for the EtherNet\/IP Coupler Units for information on the unit versions of EtherNet\/IP Units<br \/>\nthat are compatible with EtherNet\/IP Coupler Units.<br \/>\n*2 Refer to the user\u2019s manual for the EtherNet\/IP Coupler Units for information on the unit versions of CPU Units and<br \/>\nEtherNet\/IP Units that are compatible with EtherNet\/IP Coupler Units.<br \/>\n*3 Serial communications instructions for CIF Units cannot be used if they are connected to an EtherNet\/IP Coupler Unit.<br \/>\n*4 For connection to an EtherNet\/IP Coupler Unit with unit version 1.0, You can connect only to the peripheral USB port on<br \/>\nthe EtherNet\/IP Coupler Unit. You cannot connect with any other path. If you need to connect by another path, use an<br \/>\nEtherNet\/IP Coupler Unit with unit version 1.2 or later.<\/div>\n<\/div>\n<\/div>\n<div><\/div>\n<div><\/div>\n<div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>(Unit: mm)<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>NX-CIF101 and NX-CIF105<\/strong><\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3479_dm_113-257382.gif\" alt=\"NX-CIF Dimensions 1 \" \/><\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p><strong>NX-CIF210<\/strong><\/p>\n<\/div>\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3479_dm_213-257383.gif\" alt=\"NX-CIF Dimensions 2 \" \/><\/div>\n<\/div>\n<\/div>\n<div><\/div>\n<div><\/div>\n<div>\n<table id=\"global_data\" class=\"tableA01 tablesorter\" border=\"1\" cellspacing=\"0\">\n<thead>\n<tr class=\"tablesorter-header\">\n<th class=\"dl_name\">\n<div class=\"tablesorter-header-inner\">Catalog Name<\/div>\n<\/th>\n<th class=\"dl_cat_number\">\n<div class=\"tablesorter-header-inner\">Catalog Number<br \/>\n[size]<\/div>\n<\/th>\n<th class=\"dl_date tablesorter-header\">\n<div class=\"tablesorter-header-inner\">Last Update<\/div>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"odd first-child\">\n<td><a href=\"http:\/\/www.ia.omron.com\/data_pdf\/cat\/nx-cif_ds_e_7_2_csm1041658.pdf?id=3479\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" class=\"iconD01\" src=\"http:\/\/www.ia.omron.com\/resources\/images\/icon_pdf.gif\" alt=\"\" width=\"11\" height=\"12\" \/>\u00a0NX-CIF Data Sheet<\/a><\/td>\n<td>&#8211;<br \/>\n<span class=\"file-size\">[2315KB]<\/span><\/td>\n<td class=\"td_date\">Aug 01, 2018<\/td>\n<\/tr>\n<tr class=\"even\">\n<td><a href=\"http:\/\/www.ia.omron.com\/data_pdf\/cat\/nx_series_r183-e1_7_6_csm1040123.pdf?id=3479\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" class=\"iconD01\" src=\"http:\/\/www.ia.omron.com\/resources\/images\/icon_pdf.gif\" alt=\"\" width=\"11\" height=\"12\" \/>\u00a0NX-series I\/O System Catalog<\/a><\/td>\n<td>R183-E1-09<br \/>\n<span class=\"file-size\">[6683KB]<\/span><\/td>\n<td class=\"td_date\">Nov 01, 2018<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h2 class=\"heading-B02\">Provides simplicity and flexibility in connecting serial devices to EtherCAT<\/h2>\n","protected":false},"featured_media":1397,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[98,63,72],"product_tag":[],"_links":{"self":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product\/1396"}],"collection":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/comments?post=1396"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/media\/1397"}],"wp:attachment":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/media?parent=1396"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=1396"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=1396"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}