{"id":1392,"date":"2019-01-02T02:57:09","date_gmt":"2019-01-02T02:57:09","guid":{"rendered":"http:\/\/al-tet-onlinesales.allyoulovetrading.com\/?post_type=product&#038;p=1392"},"modified":"2019-01-02T02:57:10","modified_gmt":"2019-01-02T02:57:10","slug":"nx-ecs-3","status":"publish","type":"product","link":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/product\/nx-ecs-3\/","title":{"rendered":"NX-ECS[][][]"},"content":{"rendered":"<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>\u2022 SSI clock frequency up to 2 MHz<\/p>\n<p>\u2022 High-speed remote I\/O control with communications cycle as fast as 125 \u03bcs*1<\/p>\n<p>\u2022 Free-run refreshing, synchronous I\/O refreshing, or task period prioritized refreshing*2 with the NX1P2 CPU Unit or EtherCAT Coupler Unit<\/p>\n<p>\u2022 The MC Function Modules of the NJ\/NX\/NY5 Controllers allows the encoder to be used as a motion axis<\/p>\n<p>\u2022 Choice of SSI Coding Methods (No conversion, binary code, or gray code)<\/p>\n<p>\u2022 Time Stamping<\/p>\n<p>\u2022 Multi-turn and single-turn encoders supported<\/p>\n<p>\u2022 Data Refresh Status (Data refreshing can be checked on the host controller.)<\/p>\n<p>\u2022 Maximum connecting SSI cable length: 400 m<\/p>\n<p>\u2022 Connect to the CJ PLC using the EtherNet\/IP<sup>TM<\/sup>\u00a0bus coupler<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>*1. When using the NX-EC01[][] together with the NX701-[][][][] and NX-ECC203.<br \/>\n*2. Task Period Prioritized refreshing is available when the NX-ECC203 is used together.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Sysmac is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products.<br \/>\nEtherCAT\u00ae is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany. EtherNet\/IP\u2122 is a trademark of ODVA.<br \/>\nOther company names and product names in this document are the trademarks or registered trademarks of their respective companies.<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h4 class=\"heading-B02\">Applicable standards<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Refer to the OMRON website (www.ia.omron.com) or ask your OMRON representative for the most recent applicable standards for each model.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Position Interface: SSI Input Units<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Product<br \/>\nname<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"5\" rowspan=\"1\"><strong>Specification<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Number<br \/>\nof<br \/>\nchannels<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Input\/<br \/>\nOutput<br \/>\nform<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Maximum<br \/>\ndata<br \/>\nlength<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Encoder<br \/>\npower<br \/>\nsupply<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Type of<br \/>\nexternal<br \/>\nconnections<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>SSI Input<br \/>\nUnits<br \/>\n<img title=\"3191_lu_1_1\" src=\"http:\/\/www.ia.omron.com\/Images\/3191_lu_1_113-172517.gif\" alt=\"3191_lu_1_1\" \/><\/strong><\/th>\n<td class=\"center middle\">1<\/td>\n<td class=\"left middle\">EIA standard<br \/>\nRS-422-A<\/td>\n<td class=\"left middle\">32 bits<\/td>\n<td class=\"left middle\">24 VDC,<br \/>\n0.3 A\/CH<\/td>\n<td class=\"left middle\">Screwless push-<br \/>\nin terminal block<br \/>\n(12 terminals)<\/td>\n<td class=\"left middle\"><strong>NX-ECS112<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">2<\/td>\n<td class=\"left middle\">EIA standard<br \/>\nRS-422-A<\/td>\n<td class=\"left middle\">32 bits<\/td>\n<td class=\"left middle\">24 VDC,<br \/>\n0.3 A\/CH<\/td>\n<td class=\"left middle\">Screwless push-<br \/>\nin terminal block<br \/>\n(12 terminals)<\/td>\n<td class=\"left middle\"><strong>NX-ECS212<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Optional Products<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\"><strong>Product name<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Specification<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Unit\/Terminal Block Coding Pins<\/strong><\/th>\n<td class=\"left middle\">For 10 Units (Terminal Block: 30 pins, Unit: 30 pins)<\/td>\n<td class=\"left middle\"><strong>NX-AUX02<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Product name<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"4\" rowspan=\"1\"><strong>Specification<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>No. of<br \/>\nterminals<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Terminal number<br \/>\nindications<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Ground<br \/>\nterminal mark<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Terminal current<br \/>\ncapacity<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Terminal Block<\/strong><\/th>\n<td class=\"center middle\">12<\/td>\n<td class=\"center middle\">C\/D<\/td>\n<td class=\"center middle\">None<\/td>\n<td class=\"center middle\">10 A<\/td>\n<td class=\"center middle\"><strong>NX-TBB122<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Accessories<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Not included.<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h4 class=\"heading-A01\">General Specification<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Item<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Specification<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Enclosure<\/strong><\/th>\n<td class=\"left middle\">Mounted in a panel<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Grounding method<\/strong><\/th>\n<td class=\"left middle\">Ground to less than 100 \u03a9<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"11\"><strong>Operating<br \/>\nenvironment<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Ambient operating<br \/>\ntemperature<\/strong><\/th>\n<td class=\"left middle\">0 to 55\u00b0C<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Ambient operating<br \/>\nhumidity<\/strong><\/th>\n<td class=\"left middle\">10% to 95% (with no condensation or icing)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Atmosphere<\/strong><\/th>\n<td class=\"left middle\">Must be free from corrosive gases.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Ambient storage<br \/>\ntemperature<\/strong><\/th>\n<td class=\"left middle\">-25 to 70\u00b0C (with no condensation or icing)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Altitude<\/strong><\/th>\n<td class=\"left middle\">2,000 m max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Pollution degree<\/strong><\/th>\n<td class=\"left middle\">Pollution degree 2 or less: Conforms to JIS B3502 and IEC 61131-2.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Noise immunity<\/strong><\/th>\n<td class=\"left middle\">Conforms to IEC61000-4-4, 2 kV (power supply line)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Overvoltage category<\/strong><\/th>\n<td class=\"left middle\">Category II: Conforms to JIS B3502 and IEC 61131-2.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>EMC immunity level<\/strong><\/th>\n<td class=\"left middle\">Zone B<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Vibration resistance<\/strong><\/th>\n<td class=\"left middle\">Conforms to IEC 60068-2-6.<br \/>\n5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz, acceleration of 9.8 m\/s<sup>2<\/sup>,<br \/>\n100 min each in X, Y, and Z directions (10 sweeps of 10 min each = 100 min<br \/>\ntotal)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Shock resistance<\/strong><\/th>\n<td class=\"left middle\">Conforms to IEC 60068-2-27. 147 m\/s<sup>2<\/sup>, 3 times each in X, Y, and Z directions<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Applicable standards *<\/strong><\/th>\n<td class=\"left middle\">cULus: Listed (UL508) or Listed (UL 61010-2-201), ANSI\/ISA 12.12.01,<br \/>\nEU: EN 61131-2, C-Tick or RCM, KC Registration, NK, LR<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>* Ask your OMRON representative for the most recent applicable standards for each model.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A01\">SSI Input Unit Specifications<\/h4>\n<h4 class=\"heading-A02\">SSI Input Unit 1 channel NX-ECS112<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading left middle\"><strong>Unit name<\/strong><\/th>\n<td class=\"left middle\">SSI Input Unit<\/td>\n<th class=\"heading left middle\"><strong>Model<\/strong><\/th>\n<td class=\"left middle\">NX-ECS112<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of channels<\/strong><\/th>\n<td class=\"left middle\">1 channel<\/td>\n<th class=\"heading left middle\"><strong>Type of external<br \/>\nconnections<\/strong><\/th>\n<td class=\"left middle\">Screwless push-in terminal block<br \/>\n(12 terminals)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>I\/O refreshing method<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Free-Run refreshing, synchronous I\/O refreshing or task period prioritized refreshing *1<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Indicators<\/strong><\/th>\n<td class=\"left middle\"><img title=\"3191_sp_2_1\" src=\"http:\/\/www.ia.omron.com\/Images\/3191_sp_2_113-172518.gif\" alt=\"3191_sp_2_1\" \/><\/td>\n<th class=\"heading left middle\"><strong>Input signals<\/strong><\/th>\n<td class=\"left middle\">External inputs: 2 Data input (D+, D-)<br \/>\nExternal outputs: 2 Clock output (C+,<br \/>\nC-)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>I\/O interface<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Synchronized serial interface (SSI)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Clock output<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">EIA standard RS-422-A line driver levels<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Data input<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">EIA standard RS-422-A line receiver levels<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum data length<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">32 bits (The single-turn, multi-turn, and status data length can be set.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Coding method<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">No conversion, binary code, or gray code<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Baud Rate<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">100 kHz, 200 kHz, 300 kHz, 400 kHz, 500 kHz, 1.0 MHz, 1.5 MHz, or 2.0 MHz<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Dimensions<\/strong><\/th>\n<td class=\"left middle\">12 \u00d7 100 \u00d7 71 mm<br \/>\n(W \u00d7 H \u00d7 D)<\/td>\n<th class=\"heading left middle\"><strong>Isolation method<\/strong><\/th>\n<td class=\"left middle\">Digital isolator<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Insulation resistance<\/strong><\/th>\n<td class=\"left middle\">20 M\u03a9 min. between isolated<br \/>\ncircuits (at 100 VDC)<\/td>\n<th class=\"heading left middle\"><strong>Dielectric<br \/>\nstrength<\/strong><\/th>\n<td class=\"left middle\">510 VAC between isolated circuits for<br \/>\n1 minute with leakage current of 5 mA<br \/>\nmax.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>I\/O power supply<br \/>\nsource<\/strong><\/th>\n<td class=\"left middle\">Supplied from the NX bus.<br \/>\n20.4 to 28.8 VDC<br \/>\n(24 VDC +20%\/-15%)<\/td>\n<th class=\"heading left middle\"><strong>Current capacity<br \/>\nof I\/O power<br \/>\nsupply terminals<\/strong><\/th>\n<td class=\"left middle\">IOV: 0.3 A max. per terminal<br \/>\nIOG: 0.3 A max. per terminal<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>NX Unit power<br \/>\nconsumption<\/strong><\/th>\n<td class=\"left middle\">\u2022 Connected to a CPU Unit<br \/>\n1.20 W max.<br \/>\n\u2022 Connected to a Commu-<br \/>\nnications Coupler Unit<br \/>\n0.85 W max.<\/td>\n<th class=\"heading left middle\"><strong>Current<br \/>\nconsumption from<br \/>\nI\/O power supply<\/strong><\/th>\n<td class=\"left middle\">20mA<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"9\"><strong>Maximum transmission<br \/>\ndistance *2<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Baud Rate<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Maximum transmission distance<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\">100 kHz<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">400m<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">200 kHz<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">190m<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">300 kHz<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">120m<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">400 kHz<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">80m<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">500 kHz<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">60m<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">1.0 MHz<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">25m<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">1.5 MHz<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">10m<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">2.0 MHz<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">5m<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Weight<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">65g<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Circuit layout<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\"><img title=\"3191_sp_2_2\" src=\"http:\/\/www.ia.omron.com\/Images\/3191_sp_2_213-172519.gif\" alt=\"3191_sp_2_2\" \/><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Installation orientation<br \/>\nand restrictions<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Installation orientation:<br \/>\n\u2022 Connected to a CPU Unit: Possible in upright installation.<br \/>\n\u2022 Connected to a Communications Coupler Unit: Possible in 6 orientations.<br \/>\nRestrictions: No restrictions<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Terminal connection<br \/>\ndiagram<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\"><img title=\"3191_sp_2_3\" src=\"http:\/\/www.ia.omron.com\/Images\/3191_sp_2_313-172513.gif\" alt=\"3191_sp_2_3\" \/><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Failure detection<\/strong><\/th>\n<td class=\"left middle\">None<\/td>\n<th class=\"heading left middle\"><strong>Protection<\/strong><\/th>\n<td class=\"left middle\">None<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>*1. The I\/O refreshing method is automatically set according to the connected Communications Coupler Unit and CPU<br \/>\nUnit.<br \/>\nRefer to information on the I\/O refreshing methods in the W524 manual for the communications cycles for each<br \/>\nmodel.<br \/>\n*2. The maximum transmission distance for an SSI Input Unit depends on the baud rate due to the delay that can result<br \/>\nfrom the responsiveness of the connected encoder and cable impedance. The maximum transmission distance is<br \/>\nonly a guideline. Review the specifications for the cables and encoders in the system and evaluate the operation of<br \/>\nthe equipment before use.<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">SSI Input Unit 2 channel NX-ECS212<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading left middle\"><strong>Unit name<\/strong><\/th>\n<td class=\"left middle\">SSI Input Unit<\/td>\n<th class=\"heading left middle\"><strong>Model<\/strong><\/th>\n<td class=\"left middle\">NX-ECS212<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of channels<\/strong><\/th>\n<td class=\"left middle\">2 channels<\/td>\n<th class=\"heading left middle\"><strong>Type of external<br \/>\nconnections<\/strong><\/th>\n<td class=\"left middle\">Screwless push-in terminal block<br \/>\n(12 terminals)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>I\/O refreshing method<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Free-Run refreshing, synchronous I\/O refreshing or task period prioritized refreshing *1<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Indicators<\/strong><\/th>\n<td class=\"left middle\"><img title=\"3191_sp_3_1\" src=\"http:\/\/www.ia.omron.com\/Images\/3191_sp_3_113-172514.gif\" alt=\"3191_sp_3_1\" \/><\/td>\n<th class=\"heading left middle\"><strong>Input signals<\/strong><\/th>\n<td class=\"left middle\">External inputs: 2 Data input (D+, D-)<br \/>\nExternal outputs: 2 Clock output (C+,<br \/>\nC-)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>I\/O interface<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Synchronized serial interface (SSI)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Clock output<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">EIA standard RS-422-A line driver levels<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Data input<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">EIA standard RS-422-A line receiver levels<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum data length<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">32 bits (The single-turn, multi-turn, and status data length can be set.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Coding method<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">No conversion, binary code, or gray code<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Baud Rate<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">100 kHz, 200 kHz, 300 kHz, 400 kHz, 500 kHz, 1.0 MHz, 1.5 MHz, or 2.0 MHz<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Dimensions<\/strong><\/th>\n<td class=\"left middle\">12 \u00d7 100 \u00d7 71 mm<br \/>\n(W \u00d7 H \u00d7 D)<\/td>\n<th class=\"heading left middle\"><strong>Isolation method<\/strong><\/th>\n<td class=\"left middle\">Digital isolator<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Insulation resistance<\/strong><\/th>\n<td class=\"left middle\">20 M\u03a9 min. between isolated<br \/>\ncircuits (at 100 VDC)<\/td>\n<th class=\"heading left middle\"><strong>Dielectric<br \/>\nstrength<\/strong><\/th>\n<td class=\"left middle\">510 VAC between isolated circuits for<br \/>\n1 minute with leakage current of 5 mA<br \/>\nmax.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>I\/O power supply<br \/>\nsource<\/strong><\/th>\n<td class=\"left middle\">Supplied from the NX bus.<br \/>\n20.4 to 28.8 VDC<br \/>\n(24 VDC +20%\/-15%)<\/td>\n<th class=\"heading left middle\"><strong>Current capacity<br \/>\nof I\/O power<br \/>\nsupply terminals<\/strong><\/th>\n<td class=\"left middle\">IOV: 0.3 A max. per terminal<br \/>\nIOG: 0.3 A max. per terminal<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>NX Unit power<br \/>\nconsumption<\/strong><\/th>\n<td class=\"left middle\">\u2022 Connected to a CPU Unit<br \/>\n1.25 W max.<br \/>\n\u2022 Connected to a Commu-<br \/>\nnications Coupler Unit<br \/>\n0.9 W max.<\/td>\n<th class=\"heading left middle\"><strong>Current<br \/>\nconsumption from<br \/>\nI\/O power supply<\/strong><\/th>\n<td class=\"left middle\">30mA<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"9\"><strong>Maximum transmission<br \/>\ndistance *2<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Baud Rate<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Maximum transmission distance<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\">100 kHz<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">400m<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">200 kHz<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">190m<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">300 kHz<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">120m<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">400 kHz<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">80m<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">500 kHz<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">60m<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">1.0 MHz<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">25m<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">1.5 MHz<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">10m<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">2.0 MHz<\/td>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">5m<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Weight<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">65g<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Circuit layout<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\"><img title=\"3191_sp_3_2\" src=\"http:\/\/www.ia.omron.com\/Images\/3191_sp_3_213-172515.gif\" alt=\"3191_sp_3_2\" \/><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Installation orientation<br \/>\nand restrictions<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Installation orientation:<br \/>\n\u2022 Connected to a CPU Unit: Possible in upright installation.<br \/>\n\u2022 Connected to a Communications Coupler Unit: Possible in 6 orientations.<br \/>\nRestrictions: No restrictions<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Terminal connection<br \/>\ndiagram<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\"><img title=\"3191_sp_3_3\" src=\"http:\/\/www.ia.omron.com\/Images\/3191_sp_3_313-172516.gif\" alt=\"3191_sp_3_3\" \/><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Failure detection<\/strong><\/th>\n<td class=\"left middle\">None<\/td>\n<th class=\"heading left middle\"><strong>Protection<\/strong><\/th>\n<td class=\"left middle\">None<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>*1. The I\/O refreshing method is automatically set according to the connected Communications Coupler Unit and CPU<br \/>\nUnit.<br \/>\nRefer to information on the I\/O refreshing methods in the W524 manual for the communications cycles for each<br \/>\nmodel.<br \/>\n*2. The maximum transmission distance for an SSI Input Unit depends on the baud rate due to the delay that can result<br \/>\nfrom the responsiveness of the connected encoder and cable impedance. The maximum transmission distance is<br \/>\nonly a guideline. Review the specifications for the cables and encoders in the system and evaluate the operation of<br \/>\nthe equipment before use.<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A01\">Version Information<\/h4>\n<h4 class=\"heading-A02\">Connected to a CPU Unit<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Refer to the user&#8217;s manual for the CPU Unit details on the CPU Units to which NX Units can be connected.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>NX Unit<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Corresponding unit versions\/versions<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Unit version<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CPU Unit<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Sysmac Studio<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"3\">NX-ECS112<\/td>\n<td class=\"center middle\">Ver. 1.0<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"3\">Ver. 1.13<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"3\">Ver. 1.17<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">Ver. 1.1<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">Ver. 1.2<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"3\">NX-ECS212<\/td>\n<td class=\"center middle\">Ver. 1.0<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"3\">Ver. 1.13<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"3\">Ver. 1.17<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">Ver. 1.1<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">Ver. 1.2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Note: Some Units do not have all of the versions given in the above table. If a Unit does not have the specified version, support is provided by the oldest available version after the specified version. Refer to the user\u2019s manuals for the specific Units for the relation between models and versions.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Connected to an EtherCAT Coupler Unit<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>NX Unit<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"3\" rowspan=\"1\"><strong>Corresponding unit versions\/versions<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Unit version<\/strong><\/th>\n<th class=\"heading center middle\"><strong>EtherCAT<br \/>\nCoupler Unit<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CPU Unit or Industrial PC<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Sysmac Studio<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"3\">NX-ECS112<\/td>\n<td class=\"left middle\">Ver. 1.0<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">Ver. 1.1 *1<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"3\">Ver. 1.06 *1<\/td>\n<td class=\"left middle\">Ver. 1.07<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Ver. 1.1<\/td>\n<td class=\"left middle\">Ver. 1.08<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Ver. 1.2<\/td>\n<td class=\"left middle\">Ver. 1.3 *2*3<\/td>\n<td class=\"left middle\">Ver. 1.13<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"3\">NX-ECS212<\/td>\n<td class=\"left middle\">Ver. 1.0<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">Ver. 1.1 *1<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"3\">Ver. 1.06 *1<\/td>\n<td class=\"left middle\">Ver. 1.07<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Ver. 1.1<\/td>\n<td class=\"left middle\">Ver. 1.08<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Ver. 1.2<\/td>\n<td class=\"left middle\">Ver. 1.3 *2*3<\/td>\n<td class=\"left middle\">Ver. 1.13<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Note: Some Units do not have all of the versions given in the above table. If a Unit does not have the specified version, support is provided by the oldest available version after the specified version. Refer to the user\u2019s manuals for the specific Units for the relation between models and versions.<br \/>\n*1. You can use the following versions if time stamp refreshing is not used.<br \/>\n*2. To use task period prioritized refreshing, you must use the NX-ECC203.<br \/>\n*3. If you do not use task period prioritized refreshing, you can use EtherCAT Coupler Units which support Position Interface Units with unit version 1.1 or earlier.<br \/>\n*4. If you do not use task period prioritized refreshing, you can use EtherCAT Coupler Units with unit version 1.0.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Connected to an EtherNet\/IP Coupler Unit<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Unit<br \/>\nversion<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"3\" rowspan=\"1\"><strong>Application with an NJ\/NX\/NY-series Controller<br \/>\n*1<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"3\" rowspan=\"1\"><strong>Application with a CS\/CJ\/CP-series PLC *2<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>EtherNet\/IP<br \/>\nCoupler Unit<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CPU Unit or<br \/>\nIndustrial PC<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Sysmac<br \/>\nStudio<\/strong><\/th>\n<th class=\"heading center middle\"><strong>EtherNet\/IP<br \/>\nCoupler Unit<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Sysmac<br \/>\nStudio<\/strong><\/th>\n<th class=\"heading center middle\"><strong>NX-IO<br \/>\nConfigurator *3<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"3\">NX-ECS112<\/td>\n<td class=\"left middle\">Ver. 1.0<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"3\">Ver. 1.2<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"3\">Ver. 1.14<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"3\">Ver. 1.19<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"3\">Ver. 1.0<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">Ver. 1.10<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"3\">Ver. 1.00<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Ver. 1.1<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Ver. 1.2<\/td>\n<td class=\"left middle\">Ver. 1.13<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"3\">NX-ECS212<\/td>\n<td class=\"left middle\">Ver. 1.0<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"3\">Ver. 1.2<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"3\">Ver. 1.14<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"3\">Ver. 1.19<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"3\">Ver. 1.0<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">Ver. 1.10<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"3\">Ver. 1.00<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Ver. 1.1<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Ver. 1.2<\/td>\n<td class=\"left middle\">Ver. 1.13<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Note: 1. Some Units do not have all of the versions given in the above table. If a Unit does not have the specified version, support is provided by the oldest available version after the specified version. Refer to the user\u2019s manuals for the specific Units for the relation between models and versions.<br \/>\nNote: 2. You cannot connect the relevant NX Unit or use the relevant NX Unit function if \u201c&#8212;\u201d is shown in the corresponding unit versions\/versions column.<br \/>\n*1. Refer to the user&#8217;s manual of the EtherNet\/IP Coupler Unit for the unit versions of EtherNet\/IP Units corresponding to EtherNet\/IP Coupler Units.<br \/>\n*2. Refer to the user&#8217;s manual of the EtherNet\/IP Coupler Unit for the unit versions of CPU Units and EtherNet\/IP Units corresponding to EtherNet\/IP Coupler Units.<br \/>\n*3. For connection to an EtherNet\/IP Coupler Unit with unit version 1.0, connection is supported only for a connection to the peripheral USB port on the EtherNet\/IP Coupler Unit. You cannot connect by any other path. If you need to connect by another path, use an EtherNet\/IP Coupler Unit with unit version 1.2 or later.<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>(Unit: mm)<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Screwless Clamping Terminal Block Type<\/h4>\n<h4 class=\"heading-B02\">12 mm Width<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3191_dm_113-172520.gif\" alt=\"NX-ECS[][][] Dimensions 2 \" \/>&nbsp;<\/p>\n<table id=\"global_data\" class=\"tableA01 tablesorter\" border=\"1\" cellspacing=\"0\">\n<thead>\n<tr class=\"tablesorter-header\">\n<th class=\"dl_name\">\n<div class=\"tablesorter-header-inner\">Catalog Name<\/div>\n<\/th>\n<th class=\"dl_cat_number\">\n<div class=\"tablesorter-header-inner\">Catalog Number<br \/>\n[size]<\/div>\n<\/th>\n<th class=\"dl_date tablesorter-header\">\n<div class=\"tablesorter-header-inner\">Last Update<\/div>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"odd first-child\">\n<td><a href=\"http:\/\/www.ia.omron.com\/data_pdf\/cat\/nx-ec0_ecs_pg0_ds_e_2_3_csm1057424.pdf?id=3191\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" class=\"iconD01\" src=\"http:\/\/www.ia.omron.com\/resources\/images\/icon_pdf.gif\" alt=\"\" width=\"11\" height=\"12\" \/>\u00a0NX-EC0\/ECS\/PG0 Data Sheet<\/a><\/td>\n<td>&#8211;<br \/>\n<span class=\"file-size\">[7485KB]<\/span><\/td>\n<td class=\"td_date\">Aug 01, 2018<\/td>\n<\/tr>\n<tr class=\"even\">\n<td><a href=\"http:\/\/www.ia.omron.com\/data_pdf\/cat\/nx_series_r183-e1_7_6_csm1040123.pdf?id=3191\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" class=\"iconD01\" src=\"http:\/\/www.ia.omron.com\/resources\/images\/icon_pdf.gif\" alt=\"\" width=\"11\" height=\"12\" \/>\u00a0NX-series I\/O System Catalog<\/a><\/td>\n<td>R183-E1-09<br \/>\n<span class=\"file-size\">[6683KB]<\/span><\/td>\n<td class=\"td_date\">Nov 01, 2018<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Synchronous Serial Interface (SSI) to connect external axes to the Sysmac system<\/p>\n","protected":false},"featured_media":1353,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[98,63],"product_tag":[],"_links":{"self":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product\/1392"}],"collection":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/comments?post=1392"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/media\/1353"}],"wp:attachment":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/media?parent=1392"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=1392"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=1392"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}