{"id":1369,"date":"2019-01-02T01:59:11","date_gmt":"2019-01-02T01:59:11","guid":{"rendered":"http:\/\/al-tet-onlinesales.allyoulovetrading.com\/?post_type=product&#038;p=1369"},"modified":"2019-01-02T01:59:11","modified_gmt":"2019-01-02T01:59:11","slug":"nx-sl","status":"publish","type":"product","link":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/product\/nx-sl\/","title":{"rendered":"NX-SL"},"content":{"rendered":"<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>\u2022 EN ISO13849-1 (PLe\/Safety Category4), IEC 61508 (SIL3) certified.<\/p>\n<p>\u2022 One connection using Safety over EtherCAT (FSoE) * protocol enables flexible configuration by mixing the Safety Units with standard NX I\/O.<\/p>\n<p>\u2022 The Safety CPU Unit controls up to 128 Safety I\/O Units.<\/p>\n<p>\u2022 Hardware and safety circuits can be configured using the Sysmac Studio (Ver. 1.07)<\/p>\n<p>\u2022 Compliant with IEC61131-3<\/p>\n<p>\u2022 Safety programs can be standardized and reused efficiently by using POUs for design and operation.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>* Safety over EtherCAT (FsoE): The open protocol Safety over EtherCAT (abbreviated with FSoE &#8220;FailSafe over<br \/>\nEtherCAT&#8221;) defines a safety related communication layer for EtherCAT. Safety over EtherCAT meets the requirements<br \/>\nof IEC 61508 SIL 3 and enables the transfer of safe and standard information on the same communication system<br \/>\nwithout limitations with regard to transfer speed and cycle time.<\/div>\n<\/div>\n<\/div>\n<div>\n<h4 class=\"heading-A02\">Safety CPU Unit<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Unit type<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Appearance<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"4\" rowspan=\"1\"><strong>Specification<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Unit<br \/>\nversion<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Maximum number<br \/>\nof safety I\/O<br \/>\npoints<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Program<br \/>\ncapacity<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Number of<br \/>\nsafety I\/O<br \/>\nconnections<\/strong><\/th>\n<th class=\"heading center middle\"><strong>I\/O<br \/>\nrefreshing<br \/>\nmethod<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">Safety CPU<br \/>\nUnit<br \/>\n(NX-SL3[]00)<\/td>\n<td class=\"center middle\"><img title=\"3243_lu_1_1\" src=\"http:\/\/www.ia.omron.com\/Images\/3243_lu_1_113-178161.gif\" alt=\"3243_lu_1_1\" \/><\/td>\n<td class=\"center middle\">256 points<\/td>\n<td class=\"center middle\">512 KB<\/td>\n<td class=\"center middle\">32<\/td>\n<td class=\"left middle\">Free-Run<br \/>\nrefreshing<\/td>\n<td class=\"left middle\">Ver. 1.1<\/td>\n<td class=\"left middle\"><strong>NX-SL3300<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\"><img title=\"3243_lu_1_2\" src=\"http:\/\/www.ia.omron.com\/Images\/3243_lu_1_213-182768.gif\" alt=\"3243_lu_1_2\" \/><\/td>\n<td class=\"center middle\">1024 points<\/td>\n<td class=\"center middle\">2048 KB<\/td>\n<td class=\"center middle\">128<\/td>\n<td class=\"left middle\">Free-Run<br \/>\nrefreshing<\/td>\n<td class=\"left middle\">Ver. 1.1<\/td>\n<td class=\"left middle\"><strong>NX-SL3500<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Note: Refer to the NX-CSG\/SL5\/SI\/SO Datasheet for details of the NX-SL5[][][] Safety CPU Unit.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Configuration Devices<\/h4>\n<h4 class=\"heading-A03\">NX-series Communications Coupler Units<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\"><strong>Product<br \/>\nname<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Appearance<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Supported<br \/>\ncommunications<br \/>\nprotocol<\/strong><\/th>\n<th class=\"heading center middle\"><strong>NX Unit power<br \/>\nconsumption<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Maximum I\/O<br \/>\npower supply current<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><strong>EtherCAT<br \/>\nCoupler Unit<br \/>\n*1<\/strong><\/th>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"3\"><img title=\"csm001013831_lu_7_1\" src=\"http:\/\/www.ia.omron.com\/Images\/csm001013831_lu_7_113-285750.gif\" alt=\"csm001013831_lu_7_1\" \/><\/td>\n<td class=\"left middle\">Communications cycle<br \/>\nin DC Mode *2<br \/>\n250 to 4,000 \u03bcs<\/td>\n<td class=\"center middle\">1.45 W or lower<\/td>\n<td class=\"center middle\">4 A<\/td>\n<td class=\"left middle\"><strong>NX-EEC201<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">Communications cycle<br \/>\nin DC Mode *2<br \/>\n125 to 10,000 \u03bcs<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">1.25 W or lower<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">10 A<\/td>\n<td class=\"left middle\"><strong>NX-EEC202<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\"><strong>NX-EEC203<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>EtherNet\/IP<br \/>\nCoupler Unit<br \/>\n*1<\/strong><\/th>\n<td class=\"center middle\"><img title=\"csm001013831_lu_7_2\" src=\"http:\/\/www.ia.omron.com\/Images\/csm001013831_lu_7_213-285751.gif\" alt=\"csm001013831_lu_7_2\" \/><\/td>\n<td class=\"left middle\">EtherNet\/IP<\/td>\n<td class=\"center middle\">1.60 W or lower<\/td>\n<td class=\"center middle\">10 A<\/td>\n<td class=\"left middle\"><strong>NX-EIC202<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>Note: For details, refer to your local OMRON website.<br \/>\n*1 One End Cover NX-END01 is provided with the NX-series Communications Coupler Units.<br \/>\n*2 This depends on the specifications of the EtherCAT master. For example, the values are as follows when the EtherCAT<br \/>\nCoupler Unit is connected to the built-in EtherCAT port on an NJ5-series CPU Unit: 500 \u03bcs, 1,000 \u03bcs, 2,000 \u03bcs, and<br \/>\n4,000 \u03bcs. Refer to the NJ\/NX-series CPU Unit Built-in EtherCAT Port User&#8217;s Manual (Cat. No. W505) for the specifications<br \/>\nof the built-in EtherCAT ports on NJ\/NX-series CPU Units.<br \/>\nThis also depends on the unit configuration.<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Automation Software Sysmac Studio<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Please purchase a DVD and required number of licenses the first time you purchase the Sysmac Studio. DVDs and licenses are available individually. Each model of licenses does not include any DVD.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Product name<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"3\" rowspan=\"1\"><strong>Specifications<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><\/th>\n<th class=\"heading center middle\"><strong>Number of<br \/>\nlicenses<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Media<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Sysmac Studio<br \/>\nNX-I\/O Edition<br \/>\nVer.1.[][] *1<\/strong><\/th>\n<td class=\"left middle\">Sysmac Studio NX-I\/O Edition is a limited license that<br \/>\nprovides selected functions required for EtherNet\/IP<br \/>\nCoupler settings.<br \/>\n* Because this product is a license only, you need the<br \/>\nSysmac Studio Standard Edition DVD media to install it.<\/td>\n<td class=\"left middle\">1 license<\/td>\n<td class=\"center middle\">&#8212;<\/td>\n<td class=\"left middle\"><strong>SYSMAC-NE001L<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Sysmac Studio<br \/>\nSafety Edition<br \/>\nVer.1.[][] *2<\/strong><\/th>\n<td class=\"left middle\">Sysmac Studio Safety Edition is a license including<br \/>\nnecessary setting functions for the safety control<br \/>\nsystem.<br \/>\n* Because this product is a license only, you need the<br \/>\nSysmac Studio Standard Edition DVD media to install it.<\/td>\n<td class=\"left middle\">1 license<\/td>\n<td class=\"center middle\">&#8212;<\/td>\n<td class=\"left middle\"><strong>SYSMAC-FE001L<\/strong><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Sysmac Studio<br \/>\nStandard Edition<br \/>\nVer.1.[][] *3*4<\/strong><\/th>\n<td class=\"left middle\">The Sysmac Studio is the software that provides an<br \/>\nintegrated environment for setting, programming,<br \/>\ndebugging and maintenance of machine automation<br \/>\ncontrollers including the NJ\/NX-series CPU Units,<br \/>\nNY-series Industrial PC,EtherCAT Slave, and the HMI.<\/td>\n<td class=\"left middle\">1 license *5<\/td>\n<td class=\"center middle\">&#8212;<\/td>\n<td class=\"left middle\"><strong>SYSMAC-SE201L<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Sysmac Studio runs on the following OS.<br \/>\nWindows 7 (32-bit\/64-bit version)\/8(32-bit\/64-bit<br \/>\nversion)\/8.1 (32-bit\/64-bit version)\/10 (32-bit\/64-<br \/>\nbit version)<br \/>\n* Refer to your OMRON website for details such as<br \/>\nsupported models and functions.<\/td>\n<td class=\"left middle\">(Media only)<\/td>\n<td class=\"center middle\">DVD<\/td>\n<td class=\"left middle\"><strong>SYSMAC-SE200D<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>*1 With the NX-I\/O Edition, you can use only the setup functions for EtherNet\/IP Coupler.<br \/>\n*2 Safety Edition can be used with Communication Control Unit and EtherNet\/IP Coupler Unit.<br \/>\n*3 The Sysmac Studio Standard Edition with license(s) (SYSMAC-SE[][][]L) provides functions of the NX-I\/O Edition<br \/>\n(SYSMAC-NE001L).<br \/>\n*4 With the Sysmac Studio Standard Edition with license(s) (SYSMAC-SE[][][]L) version 1.10 or higher, you can use the<br \/>\nsetup functions for the EtherNet\/IP Coupler.<br \/>\n*5 Multi licenses are available for the Sysmac Studio (3, 10, 30, or 50 licenses).<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div><\/div>\n<div>\n<h4 class=\"heading-A02\">Regulations and Standards<\/h4>\n<h4 class=\"heading-A03\">NX-series Safety Control Units NX-SL3\/SI\/SO<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading left middle\"><strong>Certification body<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Standards<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>T\u00dcV Rheinland *<\/strong><\/th>\n<td class=\"left middle\">\u2022 EN ISO 13849-1<br \/>\n\u2022 EN ISO 13849-2<br \/>\n\u2022 IEC 61508 parts 1-7<br \/>\n\u2022 IEC\/EN 62061<br \/>\n\u2022 IEC\/EN 61131-2<br \/>\n\u2022 IEC 61326-3-1<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>UL<\/strong><\/th>\n<td class=\"left middle\">\u2022 NRAG (UL 508 and ANSI\/ISA 12.12.01)<br \/>\n\u2022 NRAG7 (CSA C22.2 No. 142 and CSA C22.2 No. 213)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>* The FSoE was certified for applications in which OMRON FSoE devices are connected to each other.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>The NX-series Safety Control Units allow you to build a safety control system that meets the following standards.<br \/>\n\u2022 Requirements for SIL 3 (Safety Integrity Level 3) in IEC 61508, EN 62061, (Functional Safety of Electrical\/Electronic\/<br \/>\nProgrammable Electronic Safety-related Systems)<br \/>\n\u2022 Requirements for PLe (Performance Level e) and for safety category 4 in EN ISO13849-1<br \/>\nThe NX-series Safety Control Units are also registered for RCM, EAC, and KC compliance.<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">General Specifications<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Item<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Specification<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Enclosure<\/strong><\/th>\n<td class=\"left middle\">Mounted in a panel (open)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Grounding method<\/strong><\/th>\n<td class=\"left middle\">Ground to 100 \u03a9 or less.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"14\"><strong>Operating<br \/>\nenvironment<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Ambient operating<br \/>\ntemperature<\/strong><\/th>\n<td class=\"left middle\">0 to 55\u00b0C (The upper limit of the ambient operating temperature is restricted<br \/>\nby the installation orientation.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Ambient operating<br \/>\nhumidity<\/strong><\/th>\n<td class=\"left middle\">10% to 95% (with no condensation or icing)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Atmosphere<\/strong><\/th>\n<td class=\"left middle\">Must be free from corrosive gases.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Ambient storage<br \/>\ntemperature<\/strong><\/th>\n<td class=\"left middle\">-25 to 70\u00b0C (with no condensation or icing)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Altitude<\/strong><\/th>\n<td class=\"left middle\">2,000 m max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Pollution degree<\/strong><\/th>\n<td class=\"left middle\">2 or less: Conforms to JIS B3502 and IEC 61131-2.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Noise immunity<\/strong><\/th>\n<td class=\"left middle\">Conforms to IEC 61131-2.<br \/>\n2 kV on power supply line (Conforms to IEC 61000-4-4.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Insulation class<\/strong><\/th>\n<td class=\"left middle\">Class III (SELV)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Overvoltage category<\/strong><\/th>\n<td class=\"left middle\">Category II: Conforms to JIS B3502 and IEC 61131-2.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>EMC immunity level<\/strong><\/th>\n<td class=\"left middle\">Zone B<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Vibration resistance<\/strong><\/th>\n<td class=\"left middle\">Conforms to IEC 60068-2-6.<br \/>\n5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz, acceleration of 9.8 m\/s<sup>2<\/sup>,<br \/>\n100 minutes each in X, Y, and Z directions (10 sweeps of 10 min each = 100 min<br \/>\ntotal)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Shock resistance<\/strong><\/th>\n<td class=\"left middle\">Conforms to IEC 60068-2-27.<br \/>\n147 m\/s<sup>2<\/sup>, 3 times each in X, Y, and Z directions<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Insulation resistance<\/strong><\/th>\n<td class=\"left middle\">20 M\u03a9 between isolated circuits (at 100 VDC)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Dielectric strength<\/strong><\/th>\n<td class=\"left middle\">510 VAC for 1 min between isolated circuits, leakage current: 5 mA max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Installation method<\/strong><\/th>\n<td class=\"left middle\">DIN Track (IEC 60715 TH35-7.5\/TH35-15)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Specifications of Individual Units<\/h4>\n<h4 class=\"heading-A03\">Safety CPU Unit NX-SL3300\/SL3500<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading left middle\"><strong>Unit name<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Safety CPU Unit<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Model<\/strong><\/th>\n<td class=\"left middle\">NX-SL3300<\/td>\n<td class=\"left middle\">NX-SL3500<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Maximum number of safety I\/O points<\/strong><\/th>\n<td class=\"left middle\">256 points<\/td>\n<td class=\"left middle\">1024 points<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Program capacity<\/strong><\/th>\n<td class=\"left middle\">512 KB<\/td>\n<td class=\"left middle\">2048 KB<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of safety master connections<\/strong><\/th>\n<td class=\"left middle\">32<\/td>\n<td class=\"left middle\">128<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>I\/O refreshing method<\/strong><\/th>\n<td class=\"left middle\">Free-Run refreshing<\/td>\n<td class=\"left middle\">Free-Run refreshing<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>External connection terminals<\/strong><\/th>\n<td class=\"left middle\">None<\/td>\n<td class=\"left middle\">None<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Indicators<\/strong><\/th>\n<td class=\"left middle\">[FS] LED, [VALID] LED, [DEBUG] LED,<br \/>\n[TS] LED, [RUN] LED<br \/>\n<img title=\"csm001013831_sp_3_1\" src=\"http:\/\/www.ia.omron.com\/Images\/csm001013831_sp_3_113-178162.gif\" alt=\"csm001013831_sp_3_1\" \/><\/td>\n<td class=\"left middle\">[FS] LED, [VALID] LED, [DEBUG] LED,<br \/>\n[TS] LED, [RUN] LED<br \/>\n<img title=\"csm001013831_sp_3_2\" src=\"http:\/\/www.ia.omron.com\/Images\/csm001013831_sp_3_213-182767.gif\" alt=\"csm001013831_sp_3_2\" \/><\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Dimensions<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">30 \u00d7 100 \u00d7 71 mm (W \u00d7 H \u00d7 D)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>I\/O power supply method<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Not supplied.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Current capacity of I\/O power supply<br \/>\nterminals<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">No I\/O power supply terminals<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>NX Unit power consumption<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">0.90 W max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Current consumption from I\/O power<br \/>\nsupply<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">No consumption<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Weight<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">75 g max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Installation orientation and<br \/>\nrestrictions<\/strong><\/th>\n<td class=\"left middle\" colspan=\"2\" rowspan=\"1\">Installation orientation: 6 possible orientations<br \/>\nRestrictions: None<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Function Specifications<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading left middle\" colspan=\"3\" rowspan=\"1\"><strong>Item<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Function<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"9\"><strong>Setting<br \/>\nParameters<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Safety I\/O Settings<\/strong><\/th>\n<td class=\"left middle\">You make a setting for safety process data communications and<br \/>\nconnection with safety I\/O devices.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><\/th>\n<th class=\"heading left middle\"><strong>Safety Process Data<br \/>\nCommunications<br \/>\nSettings<\/strong><\/th>\n<td class=\"left middle\">You select Safety I\/O Units to perform safety process data<br \/>\ncommunications (FSoE communications) and make necessary<br \/>\nsettings.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Safety Device<br \/>\nAllocation Settings<\/strong><\/th>\n<td class=\"left middle\">You set the connection between Safety I\/O Units and safety<br \/>\ndevices.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>EtherNet\/IP Safety Connection<br \/>\nSettings *1<\/strong><\/th>\n<td class=\"left middle\">You can register target devices of EtherNet\/IP Safety network and<br \/>\nconfigure the connection settings.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Standard I\/O<br \/>\nSettings<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Exposed Variable<br \/>\nSettings<\/strong><\/th>\n<td class=\"left middle\">You set whether to expose global variables of the Safety CPU Unit.<br \/>\nThe values of exposed variables can be referenced from NJ\/NX-<br \/>\nseries CPU Units and NY-series Industrial PCs.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Standard Process<br \/>\nData<br \/>\nCommunications *2<\/strong><\/th>\n<td class=\"left middle\">You set the devices and ports of the Standard I\/O Units for the<br \/>\nexposed variables of the Safety CPU Unit.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Safety Task Settings<\/strong><\/th>\n<td class=\"left middle\">You define the execution cycle and timing of the safety task and<br \/>\nprograms to be executed in the task.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><\/th>\n<th class=\"heading left middle\"><strong>Assigning Programs<\/strong><\/th>\n<td class=\"left middle\">You assign safety programs to execute to the task.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>I\/O Map Settings<\/strong><\/th>\n<td class=\"left middle\">The ports of Safety I\/O Units used in safety process data<br \/>\ncommunications are displayed. You assign device variables used<br \/>\nin safety programs to the I\/O ports.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"15\"><strong>Creating<br \/>\nSafety<br \/>\nPrograms<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Instruction List (Toolbox)<\/strong><\/th>\n<td class=\"left middle\">A hierarchy of the functions and function blocks that you can use<br \/>\nis displayed in the Toolbox. You can drag the required functions<br \/>\nand function blocks onto the FBD editor to insert it to a safety<br \/>\nprogram.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>FBD Programming<\/strong><\/th>\n<td class=\"left middle\">You connect variables, functions, and function blocks with<br \/>\nconnecting lines to build networks. The FBD editor is used to enter<br \/>\nthem.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"5\"><\/th>\n<th class=\"heading left middle\"><strong>Adding FBD Networks<\/strong><\/th>\n<td class=\"left middle\">You create FBD networks on the FBD editor to create algorithms.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Inserting and<br \/>\nDeleting Functions<br \/>\nand Function blocks<\/strong><\/th>\n<td class=\"left middle\">You insert and delete functions and function blocks on the FBD<br \/>\neditor.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Entry Assistance<\/strong><\/th>\n<td class=\"left middle\">When you enter functions, function blocks, or parameters, each<br \/>\ncharacter that you enter from the keyboard narrows the list of<br \/>\ncandidates that is displayed for selection.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Commenting Out<br \/>\nFBD Networks<\/strong><\/th>\n<td class=\"left middle\">You can comment out each FBD network. When a network is<br \/>\ncommented out, it is no longer executed.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Converting Programs<br \/>\ninto Function Blocks<br \/>\n*1<\/strong><\/th>\n<td class=\"left middle\">You can convert the safety program into user-defined function<br \/>\nblock.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Automatic Programming *1<\/strong><\/th>\n<td class=\"left middle\">A safety programs can be automatically generated from input and<br \/>\noutput signals and expected values of the program.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Creating Variables<\/strong><\/th>\n<td class=\"left middle\">You create variables used in safety programs in the global or local<br \/>\nvariable table.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>User-defined Function Blocks<\/strong><\/th>\n<td class=\"left middle\">You create user-defined function blocks.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><\/th>\n<th class=\"heading left middle\"><strong>Help Reference *3<\/strong><\/th>\n<td class=\"left middle\">You can display the user-defined function block help with the<br \/>\npopup menu or shortcut key.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Export\/Import<\/strong><\/th>\n<td class=\"left middle\">POUs can be exported and imported.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><\/th>\n<th class=\"heading left middle\"><strong>Programs *4<\/strong><\/th>\n<td class=\"left middle\">You can export\/import POUs.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>User-defined<br \/>\nFunction Blocks *3<\/strong><\/th>\n<td class=\"left middle\">You can export\/import user-defined function blocks.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Searching and Replacing<\/strong><\/th>\n<td class=\"left middle\">You can search for and replace strings in the variable tables,<br \/>\nprograms, and function blocks of a Safety CPU Unit.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"8\"><strong>Debugging<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Monitoring<\/strong><\/th>\n<td class=\"left middle\">Variables are monitored during safety program execution. You can<br \/>\nmonitor the present values of device variables assigned to Safety<br \/>\nI\/O Units and user-defined variables. The values can be monitored<br \/>\non the FBD editor or Watch Tab Page.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Changing the Present Values of<br \/>\nVariables<\/strong><\/th>\n<td class=\"left middle\">You can change the present values of user-defined variables and<br \/>\ndevice variables as required. You can do this on the FBD editor or<br \/>\nWatch Tab Page.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Forced Refreshing<\/strong><\/th>\n<td class=\"left middle\">The inputs from external devices and outputs to external devices<br \/>\nare refreshed with a specified value on the Sysmac Studio. The<br \/>\nspecified value is retained even if the value of the variable is<br \/>\noverwritten from the user program.<br \/>\nYou can use forced refreshing on the FBD editor or Watch Tab<br \/>\nPage.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Offline Debugging *5<\/strong><\/th>\n<td class=\"left middle\">You can check if the control program logic works as designed in<br \/>\nadvance using a special debugging function for the Simulator<br \/>\nwithout connecting online with the Safety CPU Unit.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"3\"><\/th>\n<th class=\"heading left middle\"><strong>Initial Value Settings<br \/>\n*6<\/strong><\/th>\n<td class=\"left middle\">You can set the initial values of variables when you start execution<br \/>\nof simulation.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Feedback Settings<br \/>\n*6<\/strong><\/th>\n<td class=\"left middle\">You can set input status that is linked to changes in output status<br \/>\nwhen simulator is running.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Simple Automatic<br \/>\nTest *7<\/strong><\/th>\n<td class=\"left middle\">You can check that expected values of the outputs to the inputs of<br \/>\nthe program are designed as intended using the Simulator<br \/>\nfunctions of the Safety CPU Unit.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>User Memory Usage Monitor *6<\/strong><\/th>\n<td class=\"left middle\">The memory usage of the safety control system and usage of<br \/>\nsafety network such as I\/O data size are displayed.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Debugging<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Online Functional Test *1<\/strong><\/th>\n<td class=\"left middle\">This function helps you to check the safety functional operation of<br \/>\nthe safety system.<br \/>\nYou can produce output device operation relative to the input and<br \/>\ncheck whether the system operates as expected. It is possible to<br \/>\noutput the check results.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Safety<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Safety Validation<\/strong><\/th>\n<td class=\"left middle\">You append the &#8220;safety-validated&#8221; information to a safety program<br \/>\nwhen you can ensure safety of the program after you complete<br \/>\ndebugging.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Changing Operating Mode<\/strong><\/th>\n<td class=\"left middle\">There are four operating modes; PROGRAM mode, DEBUG mode<br \/>\n(STOPPED), DEBUG mode (RUN), and RUN mode. The RUN<br \/>\nmode can be selected only for the validated safety programs.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Mainte-<br \/>\nnance<\/strong><\/th>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Generating Safety Data Logging<br \/>\nSettings File *1<\/strong><\/th>\n<td class=\"left middle\">Settings to use the safety data logging function can be generated<br \/>\nas a file.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Generating Safety Unit Restore<br \/>\nFile *1<\/strong><\/th>\n<td class=\"left middle\">A file of safety program and settings to be transferred to the Safety<br \/>\nCPU Unit using an SD memory card is generated for Safety Unit<br \/>\nRestore function.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"4\"><strong>Security<br \/>\nMeasures<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Prevention<br \/>\nof Incorrect<br \/>\nConnections<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Setting the Node<br \/>\nName<\/strong><\/th>\n<td class=\"left middle\">You set a unique name for each Safety CPU Unit to confirm that<br \/>\nyou operate the correct Safety CPU Unit.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Prevention<br \/>\nof Incorrect<br \/>\nOperation<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Safety Password<\/strong><\/th>\n<td class=\"left middle\">You can prevent unauthorized access to safety functions of Safety<br \/>\nCPU Units by setting a safety password for online operations that<br \/>\naffect the safety functions.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"2\"><strong>Prevention<br \/>\nof Theft of<br \/>\nAssets<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Data Protection<br \/>\n(Programs) *4<\/strong><\/th>\n<td class=\"left middle\">You can set passwords for individual programs to prohibit<br \/>\ndisplaying or changing them.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Data Protection<br \/>\n(User-defined<br \/>\nFunction Blocks) *3<\/strong><\/th>\n<td class=\"left middle\">You can set passwords for individual user-defined function blocks<br \/>\nto prohibit displaying or changing them.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Note: Supported only by the Sysmac Studio version 1.07 or higher.<br \/>\n*1. Supported only by the Sysmac Studio version 1.24 or higher.<br \/>\n*2. Supported if the EtherNet\/IP Coupler is selected with Sysmac Studio version 1.11 or higher.<br \/>\n*3. Supported only by the Sysmac Studio version 1.12 or higher.<br \/>\n*4. Supported only by the Sysmac Studio version 1.17 or higher.<br \/>\n*5. Supported only by the Sysmac Studio version 1.08 or higher.<br \/>\n*6. Supported only by the Sysmac Studio version 1.10 or higher.<br \/>\n*7. Supported only by the Sysmac Studio version 1.15 or higher.<br \/>\nRefer to the SYSMAC-SE[][][] Datasheet for function specifications of the Safety Control Unit.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Version Information<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>\u2022 Relationship between Unit Versions and Sysmac Studio Versions<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">EtherCAT Slave Terminal and EtherNet\/IP Slave Terminal<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>\u2022 This configuration is used to connect the Safety Control Unit to the EtherCAT Coupler Units, and the EtherCAT Slave<br \/>\nTerminal to the built-in EtherCAT master of the CPU Unit via EtherCAT.<br \/>\n\u2022 This configuration is used to connect the Safety Control Units to the EtherNet\/IP Coupler Units.<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>NX Unit<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"5\" rowspan=\"1\"><strong>Corresponding version *1<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Model number<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Unit version<\/strong><\/th>\n<th class=\"heading center middle\"><strong>EtherCAT<br \/>\nCoupler Unit<br \/>\nNX-ECC20[]<\/strong><\/th>\n<th class=\"heading center middle\"><strong>NJ\/NX-series<br \/>\nCPU Units *2<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Sysmac<br \/>\nStudio<\/strong><\/th>\n<th class=\"heading center middle\"><strong>ErherNet\/IP<br \/>\nCoupler Unit<br \/>\n(NX-EIC202)<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Sysmac<br \/>\nStudio<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">NX-SL3300<\/td>\n<td class=\"center middle\">1.0<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">1.1 or later<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">1.06 or later<\/td>\n<td class=\"center middle\">1.07 or later<\/td>\n<td class=\"center middle\">&#8212;<\/td>\n<td class=\"center middle\">&#8212;<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">1.1<\/td>\n<td class=\"center middle\">1.10 or later<\/td>\n<td class=\"center middle\">1.0 or later<\/td>\n<td class=\"center middle\">1.10 or later<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">NX-SL3500<\/td>\n<td class=\"center middle\">1.0<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">1.2 or later<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">1.07 or later<\/td>\n<td class=\"center middle\">1.08 or later<\/td>\n<td class=\"center middle\">&#8212;<\/td>\n<td class=\"center middle\">&#8212;<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">1.1<\/td>\n<td class=\"center middle\">1.10 or later<\/td>\n<td class=\"center middle\">&#8212;<\/td>\n<td class=\"center middle\">&#8212;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>*1 Some Units do not have all of the versions given in the above table.<br \/>\nIf a Unit does not have the specified version, support is provided by the oldest available version after the specified<br \/>\nversion.<br \/>\nRefer to the user\u2019s manuals for the specific Units for the relation between models and versions.<br \/>\n*2 These Units cannot be mounted to Machine Automation Controllers with NX1P CPU Units. Mount and use an EtherCAT<br \/>\nCoupler Unit instead.<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">CPU Rack<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>\u2022 This configuration is used to connect the Safety Control Units to the CPU Units.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Safety Control Unit model and version<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>NX bus master: CPU Unit<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Unit version<\/strong><\/th>\n<th class=\"heading center middle\"><strong>NX102 CPU Units<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Sysmac Studio<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">NX-SL3300<\/td>\n<td class=\"center middle\">Ver. 1.0<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"4\">Ver. 1.30<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"4\">Ver. 1.22<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">Ver. 1.1<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">NX-SL3500<\/td>\n<td class=\"center middle\">Ver. 1.0<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">Ver. 1.1<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">NX-SL5500<\/td>\n<td class=\"center middle\">Ver. 1.3<\/td>\n<td class=\"center middle\">Ver. 1.31<\/td>\n<td class=\"center middle\">Ver. 1.24<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">NX-SL5700<\/td>\n<td class=\"center middle\">Ver. 1.2<\/td>\n<td class=\"center middle\">&#8212;<\/td>\n<td class=\"center middle\">&#8212;<\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\">Ver. 1.3<\/td>\n<td class=\"center middle\">Ver. 1.31<\/td>\n<td class=\"center middle\">Ver. 1.24<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>(Unit: mm)<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-B02\">Safety CPU Unit NX-SL3300\/SL3500<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3243_dm_113-178160.gif\" alt=\"NX-SL Dimensions 1 \" \/><\/div>\n<\/div>\n<div><\/div>\n<div>\n<table id=\"global_data\" class=\"tableA01 tablesorter\" border=\"1\" cellspacing=\"0\">\n<thead>\n<tr class=\"tablesorter-header\">\n<th class=\"dl_name\">\n<div class=\"tablesorter-header-inner\">Catalog Name<\/div>\n<\/th>\n<th class=\"dl_cat_number\">\n<div class=\"tablesorter-header-inner\">Catalog Number<br \/>\n[size]<\/div>\n<\/th>\n<th class=\"dl_date tablesorter-header\">\n<div class=\"tablesorter-header-inner\">Last Update<\/div>\n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"odd first-child\">\n<td><a href=\"http:\/\/www.ia.omron.com\/data_pdf\/cat\/nx-sl_si_so_ds_e_4_7_csm1013831.pdf?id=3243\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" class=\"iconD01\" src=\"http:\/\/www.ia.omron.com\/resources\/images\/icon_pdf.gif\" alt=\"\" width=\"11\" height=\"12\" \/>\u00a0NX-SL\/SI\/SO Data Sheet<\/a><\/td>\n<td>&#8211;<br \/>\n<span class=\"file-size\">[2905KB]<\/span><\/td>\n<td class=\"td_date\">Nov 01, 2018<\/td>\n<\/tr>\n<tr class=\"even\">\n<td><a href=\"http:\/\/www.ia.omron.com\/data_pdf\/cat\/nx_f100-e1_1_3_csm1045105.pdf?id=3243\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" class=\"iconD01\" src=\"http:\/\/www.ia.omron.com\/resources\/images\/icon_pdf.gif\" alt=\"\" width=\"11\" height=\"12\" \/>\u00a0NX-Series Safety Controller Stand-alone System brochure<\/a><\/td>\n<td>F100-E1-01<br \/>\n<span class=\"file-size\">[1306KB]<\/span><\/td>\n<td class=\"td_date\">Feb 15, 2018<\/td>\n<\/tr>\n<tr class=\"odd\">\n<td><a href=\"http:\/\/www.ia.omron.com\/data_pdf\/cat\/ethercat_f101-e1_2_1_csm1057872.pdf?id=3243\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" class=\"iconD01\" src=\"http:\/\/www.ia.omron.com\/resources\/images\/icon_pdf.gif\" alt=\"\" width=\"11\" height=\"12\" \/>\u00a0NX-series Safety Controller (EtherCAT System) Catalog<\/a><\/td>\n<td>F101-E1-01<br \/>\n<span class=\"file-size\">[1136KB]<\/span><\/td>\n<td class=\"td_date\">Feb 15, 2018<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h2 class=\"heading-B02\">The Safety CPU Unit controls up to 32 Safety I\/O Units.<\/h2>\n","protected":false},"featured_media":1370,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[97,63,72],"product_tag":[],"_links":{"self":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product\/1369"}],"collection":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/comments?post=1369"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/media\/1370"}],"wp:attachment":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/media?parent=1369"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=1369"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=1369"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}