{"id":1361,"date":"2019-01-02T01:37:13","date_gmt":"2019-01-02T01:37:13","guid":{"rendered":"http:\/\/al-tet-onlinesales.allyoulovetrading.com\/?post_type=product&#038;p=1361"},"modified":"2019-01-02T01:37:14","modified_gmt":"2019-01-02T01:37:14","slug":"nx-v680c","status":"publish","type":"product","link":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/product\/nx-v680c\/","title":{"rendered":"NX-V680C"},"content":{"rendered":"<p>\u2022 Data reads\/writes are easily performed by simply setting parameters in the machine automation controller memory area.<\/p>\n<p>\u2022 Simple device configuration, in comparison with serial communication, coupled with high-speed data processing.<\/p>\n<p>\u2022 Communication programs can be easily built using the ladder program function blocks &#8220;Sysmac Library RFID Communications Library (SYSMAC-XR019)&#8221;.<\/p>\n<p>Note: Refer to the V680 series catalog (Q266) and V680 series data sheet (Q267) for more information on RFID system<br \/>\nV680 series system configurations.<br \/>\nRefer to the corresponding manual of each controller for more information on controller specifications.<\/p>\n<h4 class=\"heading-B02\">Applicable standards<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Refer to ask your OMRON representative for the most recent applicable standards for each model.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">RFID Units<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\"><strong>RFID Units<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Appearance<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Product name<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Amplifier\/Antenna<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Number of<br \/>\nUnits connected<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">NX-series<br \/>\nRFID Units<\/td>\n<td class=\"center middle\"><img title=\"3741_lu_1_1\" src=\"http:\/\/www.ia.omron.com\/Images\/3741_lu_1_113-287679.gif\" alt=\"3741_lu_1_1\" \/><\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">RFID Units<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">V680 series<\/td>\n<td class=\"center middle\">1<\/td>\n<td class=\"left middle\"><strong>NX-V680C1<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"center middle\"><img title=\"3741_lu_1_2\" src=\"http:\/\/www.ia.omron.com\/Images\/3741_lu_1_213-287680.gif\" alt=\"3741_lu_1_2\" \/><\/td>\n<td class=\"center middle\">2<\/td>\n<td class=\"left middle\"><strong>NX-V680C2<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h4 class=\"heading-A02\">General Specifications<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Item<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Specifications<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Enclosure<\/strong><\/th>\n<td class=\"left middle\">Mounted in a panel<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Grounding Methods<\/strong><\/th>\n<td class=\"left middle\">Ground to less than 100 \u03a9<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"11\"><strong>Operating<br \/>\nenvironment<\/strong><\/th>\n<th class=\"heading left middle\"><strong>Ambient operating<br \/>\ntemperature<\/strong><\/th>\n<td class=\"left middle\">0 to 55\u00b0C<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Ambient operating<br \/>\nhumidity<\/strong><\/th>\n<td class=\"left middle\">10 to 95% (with no condensation or icing)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Atmosphere<\/strong><\/th>\n<td class=\"left middle\">Must be free from corrosive gases.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Ambient storage<br \/>\ntemperature<\/strong><\/th>\n<td class=\"left middle\">-25 to 70\u00b0C (with no condensation or icing)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Altitude<\/strong><\/th>\n<td class=\"left middle\">2,000 m max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Pollution degree<\/strong><\/th>\n<td class=\"left middle\">2 or less: Conforms to JIS B3502 and IEC 61131-2<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Noise immunity<\/strong><\/th>\n<td class=\"left middle\">2 kV on power supply line (Conforms to IEC61000-4-4.)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Overvoltage category<\/strong><\/th>\n<td class=\"left middle\">Category II: Conforms to JIS B3502 and IEC 61131-2<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>EMC immunity level<\/strong><\/th>\n<td class=\"left middle\">Zone B<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Vibration resistance<\/strong><\/th>\n<td class=\"left middle\">Conforms to IEC 60068-2-6.<br \/>\n5 to 8.4 Hz with amplitude of 3.5 mm,<br \/>\n8.4 to 150 Hz, acceleration of 9.8 m\/s<sup>2<\/sup><br \/>\n100 min each in X, Y, and Z directions (10 sweeps of 10 min each = 100 min<br \/>\ntotal)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Shock resistance<\/strong><\/th>\n<td class=\"left middle\">Conforms to IEC 60068-2-27, 147 m\/s<sup>2<\/sup>, 3 times each in X, Y, and Z directions<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"2\" rowspan=\"1\"><strong>Applicable standards<\/strong><\/th>\n<td class=\"left middle\">cULus: Listed (UL61010-2-201), ANSI\/ISA12.12.01,<br \/>\nEU: EN61131-2, RCM, KC: KC Registration, EAC<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Functions<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>This section describes the functions provided in an RFID Unit.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\"><strong>Function name<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Description<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\">RF Communications option function<\/td>\n<td class=\"left middle\">This function switches the operation sequence during communications with<br \/>\nan RF Tag.<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Communications command function<\/td>\n<td class=\"left middle\">This function reads or writes the memory for a RF Tag on the antenna<br \/>\ncommunications area.<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Write protection function<\/td>\n<td class=\"left middle\">This function prevents the loss of data due to overwriting by specifying the<br \/>\nareas in which it is not possible to write to an RF Tag.<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">RF Tag service life detection function<\/td>\n<td class=\"left middle\">This function records the number of times data is rewritten to an RF Tag,<br \/>\nand determines the maximum rewrite count.<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">RF Tag memory error detection function<\/td>\n<td class=\"left middle\">This function detects an error during reading by performing CRC calculation<br \/>\nfor the memory of an RF Tag.<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">RF Tag memory error correction function<\/td>\n<td class=\"left middle\">This function detects an error during reading by performing ECC calculation<br \/>\nfor the memory of an RF Tag, and corrects the error to an appropriate value.<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">Test command function<\/td>\n<td class=\"left middle\">This function checks the margin in communications with an RF Tag, and<br \/>\nmeasures the surrounding noise.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Individual Specifications<\/h4>\n<h4 class=\"heading-A03\">NX-V680C1<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading left middle\"><strong>Unit name<\/strong><\/th>\n<td class=\"left middle\">One-channel RFID Unit<\/td>\n<th class=\"heading left middle\"><strong>Model<\/strong><\/th>\n<td class=\"left middle\">NX-V680C1<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of antennas<br \/>\nconnected<\/strong><\/th>\n<td class=\"left middle\">1<\/td>\n<th class=\"heading left middle\"><strong>External connection<br \/>\nterminal<\/strong><\/th>\n<td class=\"left middle\">FG terminal block (1 terminal)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>I\/O refreshing<br \/>\nmethod<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Free-Run Refreshing<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"6\"><strong>Indicators<\/strong><\/th>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"6\">TS indicator, RF indicator,<br \/>\nNORM indicator, and<br \/>\nERR indicator<br \/>\n<img title=\"3741_sp_3_1\" src=\"http:\/\/www.ia.omron.com\/Images\/3741_sp_3_113-287681.gif\" alt=\"3741_sp_3_1\" \/><\/td>\n<th class=\"heading left middle\"><strong>Communications<br \/>\nprotocol<\/strong><\/th>\n<td class=\"left middle\">ISO\/IEC18000-3 (15693)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Connectable<br \/>\nAntennas<\/strong><\/th>\n<td class=\"left middle\">V680-series<br \/>\nAntenna with Separate Amplifier:<br \/>\nV680-HS[][]<br \/>\nAntenna with Built-in Amplifier:<br \/>\nV680-H01-V2<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Applicable RF Tags<\/strong><\/th>\n<td class=\"left middle\">V680S-series RF or V680-series<br \/>\nRF Tags<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>RF Tag reading\/<br \/>\nwriting size<\/strong><\/th>\n<td class=\"left middle\">8,192 bytes max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Divided data size<\/strong><\/th>\n<td class=\"left middle\">16 to 128 bytes<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Backup function<\/strong><\/th>\n<td class=\"left middle\">Supported.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Dimensions<\/strong><\/th>\n<td class=\"left middle\">30 mm (W) x 100 mm (H) x<br \/>\n71 mm (D)<\/td>\n<th class=\"heading left middle\"><strong>Isolation method<\/strong><\/th>\n<td class=\"left middle\">Digital isolator isolation<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Insulation<br \/>\nresistance<\/strong><\/th>\n<td class=\"left middle\">20 M\u03a9 min. between isolated<br \/>\ncircuits (at 100 VDC)<\/td>\n<th class=\"heading left middle\"><strong>Dielectric strength<\/strong><\/th>\n<td class=\"left middle\">510 VAC between isolated circuits<br \/>\nfor 1 minute with a leakage current<br \/>\nof 5 mA max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>I\/O power supply<br \/>\nmethod<\/strong><\/th>\n<td class=\"left middle\">Supplied from the NX bus<\/td>\n<th class=\"heading left middle\"><strong>Current<br \/>\nconsumption from<br \/>\nI\/O power supply<\/strong><\/th>\n<td class=\"left middle\">\u2022 V680-H01-V2 connection<br \/>\n250 mA max.<br \/>\n\u2022 V680-HA63[] connection<br \/>\n210 mA max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>NX Unit power<br \/>\nconsumption<\/strong><\/th>\n<td class=\"left middle\">\u2022 Connected to a CPU Unit<br \/>\n1.00 W max.<br \/>\n\u2022 Connected to Communications<br \/>\nCoupler Unit<br \/>\n0.90 W max.<\/td>\n<th class=\"heading left middle\"><strong>Weight<\/strong><\/th>\n<td class=\"left middle\">120 g max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Installation<br \/>\norientation and<br \/>\nrestrictions<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Installation orientation:<br \/>\n\u2022 Connected to a CPU Unit Possible in upright installation.<br \/>\n\u2022 Connected to a Communications Coupler Unit<br \/>\nPossible in 6 orientations<\/p>\n<p>Restrictions: No restrictions<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">NX-V680C2<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading left middle\"><strong>Unit name<\/strong><\/th>\n<td class=\"left middle\">Two-channels RFID Unit<\/td>\n<th class=\"heading left middle\"><strong>Model<\/strong><\/th>\n<td class=\"left middle\">NX-V680C2<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Number of antennas<br \/>\nconnected<\/strong><\/th>\n<td class=\"left middle\">2<\/td>\n<th class=\"heading left middle\"><strong>External connection<br \/>\nterminal<\/strong><\/th>\n<td class=\"left middle\">FG terminal block (1 terminal)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>I\/O refreshing<br \/>\nmethod<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Free-Run Refreshing<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\" colspan=\"1\" rowspan=\"6\"><strong>Indicators<\/strong><\/th>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"6\">[TS] LED, [RF] LED, [NORM] LED,<br \/>\n[ERR] LED<\/p>\n<p>TS indicator, RF indicator,<br \/>\nNORM indicator, and<br \/>\nERR indicator<br \/>\n<img title=\"3741_sp_4_1\" src=\"http:\/\/www.ia.omron.com\/Images\/3741_sp_4_113-287676.gif\" alt=\"3741_sp_4_1\" \/><\/td>\n<th class=\"heading left middle\"><strong>Communications<br \/>\nprotocol<\/strong><\/th>\n<td class=\"left middle\">ISO\/IEC18000-3 (15693)<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Connectable<br \/>\nAntennas<\/strong><\/th>\n<td class=\"left middle\">V680-series<br \/>\nAntenna with Separate Amplifier:<br \/>\nV680-HS[][]<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Applicable RF Tags<\/strong><\/th>\n<td class=\"left middle\">V680S-series RF or V680-series<br \/>\nRF Tags<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>RF Tag reading\/<br \/>\nwriting size<\/strong><\/th>\n<td class=\"left middle\">8,192 bytes max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Divided data size<\/strong><\/th>\n<td class=\"left middle\">16 to 128 bytes<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Backup function<\/strong><\/th>\n<td class=\"left middle\">Supported.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Dimensions<\/strong><\/th>\n<td class=\"left middle\">30 mm (W) x 100 mm (H) x<br \/>\n71 mm (D)<\/td>\n<th class=\"heading left middle\"><strong>Isolation method<\/strong><\/th>\n<td class=\"left middle\">Digital isolator isolation<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Insulation<br \/>\nresistance<\/strong><\/th>\n<td class=\"left middle\">20 M\u03a9 min. between isolated<br \/>\ncircuits (at 100 VDC)<\/td>\n<th class=\"heading left middle\"><strong>Dielectric strength<\/strong><\/th>\n<td class=\"left middle\">510 VAC between isolated circuits<br \/>\nfor 1 minute with a leakage current<br \/>\nof 5 mA max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>I\/O power supply<br \/>\nmethod<\/strong><\/th>\n<td class=\"left middle\">Supplied from the NX bus.<\/td>\n<th class=\"heading left middle\"><strong>Current<br \/>\nconsumption from<br \/>\nI\/O power supply<\/strong><\/th>\n<td class=\"left middle\">V680-HA63[] connection<br \/>\n380 mA max<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>NX Unit power<br \/>\nconsumption<\/strong><\/th>\n<td class=\"left middle\">\u2022 Connected to a CPU Unit<br \/>\n1.00 W max.<br \/>\n\u2022 Connected to Communications<br \/>\nCoupler Unit<br \/>\n0.90 W max.<\/td>\n<th class=\"heading left middle\"><strong>Weight<\/strong><\/th>\n<td class=\"left middle\">130 g max.<\/td>\n<\/tr>\n<tr>\n<th class=\"heading left middle\"><strong>Installation<br \/>\norientation and<br \/>\nrestrictions<\/strong><\/th>\n<td class=\"left middle\" colspan=\"3\" rowspan=\"1\">Installation orientation:<br \/>\n\u2022 Connected to a CPU Unit<br \/>\nPossible in upright installation.<br \/>\n\u2022 Connected to a Communications Coupler Unit<br \/>\nPossible in 6 orientations<\/p>\n<p>Restrictions: No restrictions<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A02\">Version Information<\/h4>\n<h4 class=\"heading-A03\">Connected to a CPU Unit<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>Refer to the user&#8217;s manual for the CPU Unit for the models of CPU Unit to which RFID Units can be connected.<\/p>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>NX Units<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>Corresponding unit versions\/versions<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Units Versions<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CPU Units<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Sysmac Studio<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\">NX-V680C1<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">Ver. 1.0<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">Version 1.13 or higher<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">Version 1.25 or higher<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">NX-V680C2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Connected to an EtherCAT Coupler Unit<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>NX Unit<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"3\" rowspan=\"1\"><strong>Corresponding unit versions\/versions<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>Model<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Unit Version<\/strong><\/th>\n<th class=\"heading center middle\"><strong>EtherCAT Couplers<br \/>\nUnits<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CPU Unit or<br \/>\nIndustrial PC<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Sysmac Studio<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\">NX-V680C1<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">Ver. 1.0<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">1.0 or later *<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">1.05 or higher<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">Version 1.25 or higher<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">NX-V680C2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>* When connecting with other manufacturer&#8217;s master, use the EtherCAT Coupler Unit with unit version Ver.1.5 or later.<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-A03\">Connected to an EtherNet\/IP Coupler Unit<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div class=\"table-blockA01\">\n<table class=\"tableA01\" border=\"0\" cellspacing=\"0\">\n<tbody>\n<tr class=\"first-child\">\n<th class=\"heading center middle\" colspan=\"2\" rowspan=\"1\"><strong>NX Unit<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"6\" rowspan=\"1\"><strong>Corresponding unit versions\/versions<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Model<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"1\" rowspan=\"2\"><strong>Unit<br \/>\nVersion<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"3\" rowspan=\"1\"><strong>Use with an NJ\/NX\/NY-series Controller<br \/>\n*1<\/strong><\/th>\n<th class=\"heading center middle\" colspan=\"3\" rowspan=\"1\"><strong>Use with an CS\/CJ\/CP-series PLC<br \/>\n*2<\/strong><\/th>\n<\/tr>\n<tr>\n<th class=\"heading center middle\"><strong>EtherNet\/IP<br \/>\nCoupler Unit<\/strong><\/th>\n<th class=\"heading center middle\"><strong>CPU Unit or<br \/>\nIndustrial PC<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Sysmac<br \/>\nStudio<\/strong><\/th>\n<th class=\"heading center middle\"><strong>EtherNet\/IP<br \/>\nCoupler Unit<\/strong><\/th>\n<th class=\"heading center middle\"><strong>Sysmac<br \/>\nStudio<\/strong><\/th>\n<th class=\"heading center middle\"><strong>NX-IO<br \/>\nConfigurator<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"left middle\">NX-V680C1<\/td>\n<td class=\"center middle\" colspan=\"1\" rowspan=\"2\">Ver. 1.0<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">Version 1.2 or<br \/>\nlater<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">Version 1.14 or<br \/>\nlater<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">Version 1.25<br \/>\nor higher<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">Version 1.2 or<br \/>\nlater<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">Version 1.25<br \/>\nor higher<\/td>\n<td class=\"left middle\" colspan=\"1\" rowspan=\"2\">Version 1.13 or<br \/>\nlater<\/td>\n<\/tr>\n<tr>\n<td class=\"left middle\">NX-V680C2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<div>*1. Refer to the user&#8217;s manual of the EtherNet\/IP Coupler Unit for the unit versions of EtherNet\/IP Units corresponding to<br \/>\nEtherNet\/IP Coupler Units.<br \/>\n*2. Refer to the user&#8217;s manual of the EtherNet\/IP Coupler Unit for the unit versions of CPU Units and EtherNet\/IP Units<br \/>\ncorresponding to EtherNet\/ IP Coupler Units.<\/div>\n<\/div>\n<div>\n<div class=\"component-blockA01\">\n<div class=\"text\">\n<p>(Unit: mm)<\/p>\n<\/div>\n<\/div>\n<h4 class=\"heading-B02\">NX-V680C1 (One-channel)<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3741_dm_113-287677.gif\" alt=\"NX-V680C Dimensions 1 \" \/><\/div>\n<\/div>\n<h4 class=\"heading-B02\">NX-V680C2 (Two-channels)<\/h4>\n<div class=\"component-blockA01\">\n<div class=\"image\"><img src=\"http:\/\/www.ia.omron.com\/Images\/3741_dm_213-287678.gif\" alt=\"NX-V680C Dimensions 2 \" \/><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h2 class=\"heading-B02\">RFID V680 communications units create faster and more consistent field networks, supports controller distribution, and enables better traceability<\/h2>\n","protected":false},"featured_media":1362,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[97,63,72],"product_tag":[],"_links":{"self":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product\/1361"}],"collection":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/comments?post=1361"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/media\/1362"}],"wp:attachment":[{"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/media?parent=1361"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=1361"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/al-tet-onlinesales.adbridgessolution.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=1361"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}