Description
• Allows control of up to 32,000 points (2,000 words) per master, and ensures a high degree of simultaneity between data.
• Can be used as both a master and a slave at the same time.
• Equipped with settings and monitor functions aimed at improving both design and startup efficiency. Achieve maximum performance by using in combination with a Configurator.
• Files of master and slave settings can be uploaded and downloaded using memory cards, allowing effective debugging and easier setup.
International Standards
- The standards are abbreviated as follows: U: UL, U1: UL(Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
- Contact your OMRON representative for further details and applicable conditions for these standards.
| Unit classifi- cation |
Product name |
Specifications | Communications | No. of unit numbers allocated |
Current consumption (A) |
Model | |
|---|---|---|---|---|---|---|---|
| 5 V | 24 V | ||||||
| CJ1 CPU Bus Unit |
![]() |
Equipped with Master and Slave functionality. Controls for up to 32,000 points per Master. |
Remote I/O Communications Master (fixed allocations or user-set allocations) Remote I/O Communications Slave (fixed allocations or user-set allocations) Message communications |
1 | 0.29 | – | CJ1W-DRM21 |
• Simple backup function cannot be used.
• DeviceNet configurator cannot be used. Use CX-Integrator.
Software
How to Select Required Support Software for Your Controller
The required Support Software depends on the Controller to connect. Please check the following table when purchasing the Support Software.
| Item | Omron PLC System | Omron Machine Automation Controller System |
|---|---|---|
| Controller | CS, CJ, CP, and other series | NJ-series |
| Software | FA Integrated Tool Package CX-One | Automation Software Sysmac Studio |
FA Integrated Tool Package CX-One
| Product name |
Specifications | Model | Stand- ards |
||
|---|---|---|---|---|---|
| Number of licenses |
Media | ||||
| FA Integrated Tool Package CX-One Ver.4.[] |
The CX-One is a comprehensive software package that integrates Support Software for OMRON PLCs and components. CX-One runs on the following OS. CX-One Version 4.[] includes CX-Integrator |
1 license *1 | DVD *2 | CXONE-AL01D-V4 | – |
*1. Multi licenses (3, 10, 30, or 50 licenses) and DVD media without licenses are also available for the CX-One.
*2. The CX-One is also available on CD (CXONE-AL[][]C-V4).
Automation Software Sysmac Studio
Please purchase a DVD and required number of licenses the first time you purchase the Sysmac Studio. DVDs and licenses are available individually. Each model of licenses does not include any DVD.
| Product name |
Specifications | Model | Stand- ards |
||
|---|---|---|---|---|---|
| Number of licenses |
Media | ||||
| Sysmac Studio Standard Edition Ver.1.[][] |
The Sysmac Studio is the software that provides an integrated environment for setting, programming, debugging and maintenance of machine automation controllers including the NJ/NX-series CPU Units, NY-series Industrial PC, EtherCAT Slave, and the HMI. Sysmac Studio runs on the following OS. The Sysmac Studio Standard Edition DVD includes |
– (Media only) |
DVD | SYSMAC-SE200D | – |
| 1 license * |
– | SYSMAC-SE201L | – | ||
* Multi licenses are available for the Sysmac Studio (3, 10, 30, or 50 licenses).
Communication Specifications
| Item | Specifications | |||
|---|---|---|---|---|
| Communications protocol | DeviceNet | |||
| Connection methods | Multi-drop and T-branch connections can be combined (for trunk and branch lines) *1 | |||
| Baud rate | 500 Kbps, 250 Kbps, or 125 Kbps | |||
| Communications media | Special 5-wire cables (2 signal lines, 2 power lines, 1 shield line) Special 4-wire flat cables (2 signal lines, 2 power lines) |
|||
| Communications distances for special 5-wire cables |
Baud rate | Network length | Branch line length | Total branch line length |
| 500 kbps | 100 m max. | 6 m max. | 39 m max. | |
| 250 kbps | 250 m max. *2 | 6 m max. | 78 m max. | |
| 125 kbps | 500 m max. *2 | 6 m max. | 156 m max. | |
| Communications distances for special 4-wire flat cables |
Baud rate | Network length | Branch line length | Total branch line length |
| 500 kbps | 75 m max. | 6 m max. | 35 m max. | |
| 250 kbps | 150 m max. | 6 m max. | 48 m max. | |
| 125 kbps | 265 m max. | 6 m max. | 135 m max. | |
| Communications power supply | 24 V DC supplied externally | |||
| Max. number of nodes | 64 nodes (including Masters, Slaves, and Configurator) | |||
*2. Indicates the maximum network length when thick cables are used. Reduce the network length to 100 m max. when
using thin cables.
Network Specifications

Specifications
| Communications power supply voltage | 11 to 25 VDC | |||
|---|---|---|---|---|
| Current consumption | Communications:18 mA max. Internal circuit: 290 mA max. |
|||
| Max. number of connectable slaves |
Remote I/O, explicit message service | 63 *1 | ||
| Max. number of I/O points |
Fixed allocations | When used as a master |
2,048 points | |
| When used as a slave |
32 points | |||
| User-set allocations |
Using allocated DM Area words |
When used as a master |
16,000 points | |
| When used as a slave |
3,200 points | |||
| Using Configurator |
When used as a master |
32,000 points | ||
| When used as a slave |
4,800 points | |||
| Number of allocated words |
Fixed allocations | When used as a master |
64 input and 64 output words Software switch/status area: 25 words |
|
| When used as a slave |
1 input word, 1 output word *2 | |||
| User-set allocations |
Using allocated DM Area words |
When used as a master |
500 input and 500 output words Software switch/status area: 25 words |
|
| When used as a slave |
100 input and 100 output words *2 Software switch/status area: 25 words |
|||
| Using Configurator |
When used as a master |
500 input words x 2 blocks, 500 output words x 2 blocks Software switch/Status area: 25 words |
||
| When used as a slave |
100 input words x 1 blocks, 100 output words x 2 blocks *2 Software switch/Status area: 25 words |
|||
| Message com- munications |
Max. message length | 542 bytes *3 | ||
| Applicable Controllers | CJ/NJ Series | |||
| Max. number of Units mountable to Controller |
Fixed allocations | 3 | ||
| User-set allocations | 16 | |||
| Weight | 118 g max. | |||
*2. The Device Unit uses a node, and so connection is possible to 63 slaves only.
*3. When the DeviceNet is used as a slave, “input” and “output” respectively refer to input from the slave to the master and output from the master to the slave.
*4. The maximum message length includes the command code when using the CMND instruction. (SendCmd instruction with NJ-series controller)
(Unit: mm)
CJ1W-DRM21

|
Catalog Name
|
Catalog Number
[size] |
Last Update
|
|---|---|---|
| – [918KB] |
Feb 01, 2018 |



![NX-RS[][][][]](https://al-tet-onlinesales.adbridgessolution.com/wp-content/uploads/2019/01/NX-RS.jpg)











Reviews
There are no reviews yet.