Description
• Up to eight analog inputs per unit (NX-AD)
• Up to four analog outputs per unit (NX-DA)
• Free-run refreshing or synchronous I/O refreshing with the NX1P2 CPU Unit or EtherCAT Coupler Unit
• Sampling times down to 10 μs per channel and high resolution of 1/30,000
• Single-ended or differential input (NX-AD)
• Selecting channel to use, moving average, input disconnection detection, over range/under range detection, and user calibration
• Detachable front connector with screwless Push-In Plus terminals for easy installation and maintenance
• Compact with a width of 12 mm per unit
• Connect to the CJ PLC using the EtherNet/IPTM bus coupler
Sysmac is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products.
EtherCAT® is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.
EtherNet/IPTM is a trademark of ODVA.
Other company names and product names in this document are the trademarks or registered trademarks of their respective companies.
Applicable standards
Ask your OMRON representative for the most recent applicable standards for each model.
Analog Input Units
| Product name |
Specification | Model | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Num- ber of points |
Input range |
Reso- lution |
Conver- sion value, decimal number (0 to 100%) |
Over all accuracy (25°C) |
Input method |
Con- ver- sion time |
Input impe- dance |
I/O refre- shing method |
||
| Voltage Input type ![]() |
2 points |
-10 to +10 V |
1/8000 | -4000 to 4000 |
±0.2% (full scale) |
Single- ended input |
250 μs/ point |
1 MΩ min. |
Free-Run refreshing |
NX-AD2603 |
| Differential Input |
NX-AD2604 | |||||||||
| 1/30000 | -15000 to 15000 |
±0.1% (full scale) |
Differential Input |
10 μs/ point |
Selectable Synchronous I/O refreshing or Free-Run refreshing |
NX-AD2608 | ||||
| 4 points |
1/8000 | -4000 to 4000 |
±0.2% (full scale) |
Single- ended input |
250 μs/ point |
Free-Run refreshing |
NX-AD3603 | |||
| Differential Input |
NX-AD3604 | |||||||||
| 1/30000 | -15000 to 15000 |
±0.1% (full scale) |
Differential Input |
10 μs/ point |
Selectable Synchronous I/O refreshing or Free-Run refreshing |
NX-AD3608 | ||||
| 8 points |
1/8000 | -4000 to 4000 |
±0.2% (full scale) |
Single- ended input |
250 μs/ point |
Free-Run refreshing |
NX-AD4603 | |||
| Differential Input |
NX-AD4604 | |||||||||
| 1/30000 | -15000 to 15000 |
±0.1% (full scale) |
Differential Input |
10 μs/ point |
Selectable Synchronous I/O refreshing or Free-Run refreshing |
NX-AD4608 | ||||
| Current Input type ![]() |
2 points |
4 to 20 mA |
1/8000 | 0 to 8000 | ±0.2% (full scale) |
Single- ended input |
250 μs/ point |
250 Ω | Free-Run refreshing |
NX-AD2203 |
| Differential Input |
NX-AD2204 | |||||||||
| 1/30000 | 0 to 30000 |
±0.1% (full scale) |
Differential Input |
10 μs/ point |
Selectable Synchronous I/O refreshing or Free-Run refreshing |
NX-AD2208 | ||||
| 4 points |
1/8000 | 0 to 8000 | ±0.2% (full scale) |
Single- ended input |
250 μs/ point |
Free-Run refreshing |
NX-AD3203 | |||
| Differential Input |
NX-AD3204 | |||||||||
| 1/30000 | 0 to 30000 |
±0.1% (full scale) |
Differential Input |
10 μs/ point |
Selectable Synchronous I/O refreshing or Free-Run refreshing |
NX-AD3208 | ||||
| 8 points |
1/8000 | 0 to 8000 | ±0.2% (full scale) |
Single- ended input |
250 μs/ point |
85 Ω | Free-Run refreshing |
NX-AD4203 | ||
| Differential Input |
NX-AD4204 | |||||||||
| 1/30000 | 0 to 30000 |
±0.1% (full scale) |
Differential Input |
10 μs/ point |
Selectable Synchronous I/O refreshing or Free-Run refreshing |
NX-AD4208 | ||||
Analog Output Units
| Product name |
Specification | Model | ||||||
|---|---|---|---|---|---|---|---|---|
| Num- ber of points |
Output range |
Reso- lution |
Output setting value, decimal number (0 to 100%) |
Over all accuracy (25°C) |
Con- version time |
I/O refreshing method |
||
| Voltage Output type ![]() |
2 points |
-10 to +10V |
1/8000 | -4000 to 4000 | ±0.3% (full scale) |
250 μs/ point |
Free-Run refreshing |
NX-DA2603 |
| 1/30000 | -15000 to 15000 |
±0.1% (full scale) |
10 μs/ point |
Selectable Synchronous I/O refreshing or Free-Run refreshing |
NX-DA2605 | |||
| 4 points |
1/8000 | -4000 to 4000 | ±0.3% (full scale) |
250 μs/ point |
Free-Run refreshing |
NX-DA3603 | ||
| 1/30000 | -15000 to 15000 |
±0.1% (full scale) |
10 μs/ point |
Selectable Synchronous I/O refreshing or Free-Run refreshing |
NX-DA3605 | |||
| Current Output type ![]() |
2 points |
4 to 20 mA |
1/8000 | 0 to 8000 | ±0.3% (full scale) |
250 μs/ point |
Free-Run refreshing |
NX-DA2203 |
| 1/30000 | 0 to 30000 | ±0.1% (full scale) |
10 μs/ point |
Selectable Synchronous I/O refreshing or Free-Run refreshing |
NX-DA2205 | |||
| 4 points |
1/8000 | 0 to 8000 | ±0.3% (full scale) |
250 μs/ point |
Free-Run refreshing |
NX-DA3203 | ||
| 1/30000 | 0 to 30000 | ±0.1% (full scale) |
10 μs/ point |
Selectable Synchronous I/O refreshing or Free-Run refreshing |
NX-DA3205 | |||
Optional Products
| Product name | Specification | Model |
|---|---|---|
| Unit/Terminal Block Coding Pins | For 10 Units (Terminal Block: 30 pins, Unit: 30 pins) | NX-AUX02 |
| Product name | Specification | Model | |||
|---|---|---|---|---|---|
| No. of terminals | Terminal number indications |
Ground terminal mark |
Terminal current capacity |
||
| Terminal Block | 8 | A/B | None | 10 A | NX-TBA082 |
| 12 | NX-TBA122 | ||||
| 16 | NX-TBA162 | ||||
Accessories
Not included.
General Specifications
| Item | Specification | |
|---|---|---|
| Enclosure | Mounted in a panel | |
| Grounding method | Ground to 100 Ω or less | |
| Operating environment |
Ambient operating temperature | 0 to 55°C |
| Ambient operating humidity | 10% to 95% (with no condensation or icing) | |
| Atmosphere | Must be free from corrosive gases. | |
| Ambient storage temperature | -25 to 70°C (with no condensation or icing) | |
| Altitude | 2,000 m max. | |
| Pollution degree | 2 or less: Conforms to JIS B3502 and IEC 61131-2. | |
| Noise immunity | 2 kV on power supply line (Conforms to IEC61000-4-4.) | |
| Overvoltage category | Category II: Conforms to JIS B3502 and IEC 61131-2. | |
| EMC immunity level | Zone B | |
| Vibration resistance | Conforms to IEC 60068-2-6. 5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz, acceleration of 9.8 m/s2, 100 min each in X, Y, and Z directions (10 sweeps of 10 min each = 100 min total) |
|
| Shock resistance | Conforms to IEC 60068-2-27. 147 m/s2, 3 times each in X, Y, and Z directions |
|
| Applicable standards * | cULus: Listed (UL508), ANSI/ISA 12.12.01, EU: EN 61131-2, C-Tick or RCM, KC Registration, NK, LR |
|
* Ask your OMRON representative for the most recent applicable standards for each model.
Analog Input Unit Specifications
Analog Input Unit (voltage input type) 2 points NX-AD2603
| Unit name | Analog Input Unit (voltage input type) |
Model | NX-AD2603 | |
|---|---|---|---|---|
| Number of points | 2 points | External connection terminals |
Screwless clamping terminal block (8 terminals) |
|
| I/O refreshing method | Free-Run refreshing | |||
| Indicator | TS indicator![]() |
Input method | Single-ended input | |
| Input range | -10 to +10 V | |||
| Input conversion range |
-5 to 105% (full scale) | |||
| Absolute maximum rating |
±15 V | |||
| Input impedance | 1 MΩ min. | |||
| Resolution | 1/8000 (full scale) | |||
| Overall accuracy |
25℃ | ±0.2% (full scale) | ||
| 0 to 55℃ | ±0.4% (full scale) | |||
| Conversion time | 250 μs/point | |||
| Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
| Insulation resistance | 20 MΩ min. between isolated circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. |
|
| I/O power supply method |
Supply from the NX bus | Current capacity of I/O power supply terminal |
IOV: 0.1 A/terminal max., IOG: 0.1 A/terminal max. |
|
| NX Unit power consumption |
• Connected to a CPU Unit or Communication Control Unit 1.35 W max. • Connected to a Communi- cations Coupler Unit 1.05 W max. |
I/O current consumption |
No consumption | |
| Weight | 70 g max. | |||
| Circuit layout | ![]() |
|||
| Installation orientation and restrictions |
Installation orientation: • Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
| Terminal connection diagram |
![]() |
|||
| Input disconnection detection |
Not supported. | |||
Analog Input Unit (voltage input type) 2 points NX-AD2604
| Unit name | Analog Input Unit (voltage input type) |
Model | NX-AD2604 | |
|---|---|---|---|---|
| Number of points | 2 points | External connection terminals |
Screwless clamping terminal block (8 terminals) |
|
| I/O refreshing method | Free-Run refreshing | |||
| Indicator | TS indicator![]() |
Input method | Differential Input | |
| Input range | -10 to +10 V | |||
| Input conversion range |
-5 to 105% (full scale) | |||
| Absolute maximum rating |
±15 V | |||
| Input impedance | 1 MΩ min. | |||
| Resolution | 1/8000 (full scale) | |||
| Overall accuracy |
25℃ | ±0.2% (full scale) | ||
| 0 to 55℃ | ±0.4% (full scale) | |||
| Conversion time | 250 μs/point | |||
| Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
| Insulation resistance | 20 MΩ min. between isolated circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. |
|
| I/O power supply method |
No supply | Current capacity of I/O power supply terminal |
Without I/O power supply terminals | |
| NX Unit power consumption |
• Connected to a CPU Unit or Communication Control Unit 1.35 W max. • Connected to a Communi- cations Coupler Unit 1.05 W max. |
I/O current consumption |
No consumption | |
| Weight | 70 g max. | |||
| Circuit layout | ![]() |
|||
| Installation orientation and restrictions |
Installation orientation: • Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
| Terminal connection diagram |
![]() |
|||
| Input disconnection detection |
Not supported. | |||
Analog Input Unit (voltage input type) 2 points NX-AD2608
| Unit name | Analog Input Unit (voltage input type) |
Model | NX-AD2608 | |
|---|---|---|---|---|
| Number of points | 2 points | External connection terminals |
Screwless clamping terminal block (8 terminals) |
|
| I/O refreshing method | Selectable Synchronous I/O refreshing or Free-Run refreshing | |||
| Indicator | TS indicator![]() |
Input method | Differential Input | |
| Input range | -10 to +10 V | |||
| Input conversion range |
-5 to 105% (full scale) | |||
| Absolute maximum rating |
±15 V | |||
| Input impedance | 1 MΩ min. | |||
| Resolution | 1/30000 (full scale) | |||
| Overall accuracy |
25℃ | ±0.1% (full scale) | ||
| 0 to 55℃ | ±0.2% (full scale) | |||
| Conversion time | 10 μs/point | |||
| Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
| Insulation resistance | 20 MΩ min. between isolated circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. |
|
| I/O power supply method |
No supply | Current capacity of I/O power supply terminal |
Without I/O power supply terminals | |
| NX Unit power consumption |
• Connected to a CPU Unit or Communication Control Unit 1.35 W max. • Connected to a Communi- cations Coupler Unit 1.05 W max. |
I/O current consumption |
No consumption | |
| Weight | 70 g max. | |||
| Circuit layout | ![]() |
|||
| Installation orientation and restrictions |
Installation orientation: • • Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
| Terminal connection diagram |
![]() |
|||
| Input disconnection detection |
Not supported. | |||
Analog Input Unit (voltage input type) 4 points NX-AD3603
| Unit name | Analog Input Unit (voltage input type) |
Model | NX-AD3603 | |
|---|---|---|---|---|
| Number of points | 4 points | External connection terminals |
Screwless clamping terminal block (12 terminals) |
|
| I/O refreshing method | Free-Run refreshing | |||
| Indicator | TS indicator![]() |
Input method | Single-ended input | |
| Input range | -10 to +10 V | |||
| Input conversion range |
-5 to 105% (full scale) | |||
| Absolute maximum rating |
±15 V | |||
| Input impedance | 1 MΩ min. | |||
| Resolution | 1/8000 (full scale) | |||
| Overall accuracy |
25℃ | ±0.2% (full scale) | ||
| 0 to 55℃ | ±0.4% (full scale) | |||
| Conversion time | 250 μs/point | |||
| Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
| Insulation resistance | 20 MΩ min. between isolated circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. |
|
| I/O power supply method |
Supply from the NX bus | Current capacity of I/O power supply terminal |
IOV: 0.1 A/terminal max., IOG: 0.1 A/terminal max. |
|
| NX Unit power consumption |
• Connected to a CPU Unit or Communication Control Unit 1.35 W max. • Connected to a Communi- cations Coupler Unit 1.10 W max. |
I/O current consumption |
No consumption | |
| Weight | 70 g max. | |||
| Circuit layout | ![]() |
|||
| Installation orientation and restrictions |
Installation orientation: • Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
| Terminal connection diagram |
![]() |
|||
| Input disconnection detection |
Not supported. | |||
Analog Input Unit (voltage input type) 4 points NX-AD3604
| Unit name | Analog Input Unit (voltage input type) |
Model | NX-AD3604 | |
|---|---|---|---|---|
| Number of points | 4 points | External connection terminals |
Screwless clamping terminal block (12 terminals) |
|
| I/O refreshing method | Free-Run refreshing | |||
| Indicator | TS indicator![]() |
Input method | Differential Input | |
| Input range | -10 to +10 V | |||
| Input conversion range |
-5 to 105% (full scale) | |||
| Absolute maximum rating |
±15 V | |||
| Input impedance | 1 MΩ min. | |||
| Resolution | 1/8000 (full scale) | |||
| Overall accuracy |
25℃ | ±0.2% (full scale) | ||
| 0 to 55℃ | ±0.4% (full scale) | |||
| Conversion time | 250 μs/point | |||
| Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
| Insulation resistance | 20 MΩ min. between isolated circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. |
|
| I/O power supply method |
No supply | Current capacity of I/O power supply terminal |
Without I/O power supply terminals | |
| NX Unit power consumption |
• Connected to a CPU Unit or Communication Control Unit 1.35 W max. • Connected to a Communi- cations Coupler Unit 1.10 W max. |
I/O current consumption |
No consumption | |
| Weight | 70 g max. | |||
| Circuit layout | ![]() |
|||
| Installation orientation and restrictions |
Installation orientation: • Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
| Terminal connection diagram |
![]() |
|||
| Input disconnection detection |
Not supported. | |||
Analog Input Unit (voltage input type) 4 points NX-AD3608
| Unit name | Analog Input Unit (voltage input type) |
Model | NX-AD3608 | |
|---|---|---|---|---|
| Number of points | 4 points | External connection terminals |
Screwless clamping terminal block (12 terminals) |
|
| I/O refreshing method | Selectable Synchronous I/O refreshing or Free-Run refreshing | |||
| Indicator | TS indicator![]() |
Input method | Differential Input | |
| Input range | -10 to +10 V | |||
| Input conversion range |
-5 to 105% (full scale) | |||
| Absolute maximum rating |
±15 V | |||
| Input impedance | 1 MΩ min. | |||
| Resolution | 1/30000 (full scale) | |||
| Overall accuracy |
25℃ | ±0.1% (full scale) | ||
| 0 to 55℃ | ±0.2% (full scale) | |||
| Conversion time | 10 μs/point | |||
| Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
| Insulation resistance | 20 MΩ min. between isolated circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. |
|
| I/O power supply method |
No supply | Current capacity of I/O power supply terminal |
Without I/O power supply terminals | |
| NX Unit power consumption |
• Connected to a CPU Unit or Communication Control Unit 1.45 W max. • Connected to a Communi- cations Coupler Unit 1.10 W max. |
I/O current consumption |
No consumption | |
| Weight | 70 g max. | |||
| Circuit layout | ![]() |
|||
| Installation orientation and restrictions |
Installation orientation: • Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
| Terminal connection diagram |
![]() |
|||
| Input disconnection detection |
Not supported. | |||
Analog Input Unit (voltage input type) 8 points NX-AD4603
| Unit name | Analog Input Unit (voltage input type) |
Model | NX-AD4603 | |
|---|---|---|---|---|
| Number of points | 8 points | External connection terminals |
Screwless clamping terminal block (16 terminals) |
|
| I/O refreshing method | Free-Run refreshing | |||
| Indicator | TS indicator![]() |
Input method | Single-ended input | |
| Input range | -10 to +10 V | |||
| Input conversion range |
-5 to 105% (full scale) | |||
| Absolute maximum rating |
±15 V | |||
| Input impedance | 1 MΩ min. | |||
| Resolution | 1/8000 (full scale) | |||
| Overall accuracy |
25℃ | ±0.2% (full scale) | ||
| 0 to 55℃ | ±0.4% (full scale) | |||
| Conversion time | 250 μs/point | |||
| Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
| Insulation resistance | 20 MΩ min. between isolated circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. |
|
| I/O power supply method |
Supply from the NX bus | Current capacity of I/O power supply terminal |
IOG: 0.1 A/terminal max. | |
| NX Unit power consumption |
• Connected to a CPU Unit or Communication Control Unit 1.45 W max. • Connected to a Communi- cations Coupler Unit 1.15 W max. |
I/O current consumption |
No consumption | |
| Weight | 70 g max. | |||
| Circuit layout | ![]() |
|||
| Installation orientation and restrictions |
Installation orientation: • Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
| Terminal connection diagram |
![]() |
|||
| Input disconnection detection |
Not supported. | |||
Analog Input Unit (voltage input type) 8 points NX-AD4604
| Unit name | Analog Input Unit (voltage input type) |
Model | NX-AD4604 | |
|---|---|---|---|---|
| Number of points | 8 points | External connection terminals |
Screwless clamping terminal block (16 terminals) |
|
| I/O refreshing method | Free-Run refreshing | |||
| Indicator | TS indicator![]() |
Input method | Differential Input | |
| Input range | -10 to +10 V | |||
| Input conversion range |
-5 to 105% (full scale) | |||
| Absolute maximum rating |
±15 V | |||
| Input impedance | 1 MΩ min. | |||
| Resolution | 1/8000 (full scale) | |||
| Overall accuracy |
25℃ | ±0.2% (full scale) | ||
| 0 to 55℃ | ±0.4% (full scale) | |||
| Conversion time | 250 μs/point | |||
| Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
| Insulation resistance | 20 MΩ min. between isolated circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. |
|
| I/O power supply method |
No supply | Current capacity of I/O power supply terminal |
Without I/O power supply terminals | |
| NX Unit power consumption |
• Connected to a CPU Unit or Communication Control Unit 1.45 W max. • Connected to a Communi- cations Coupler Unit 1.15 W max. |
I/O current consumption |
No consumption | |
| Weight | 70 g max. | |||
| Circuit layout | ![]() |
|||
| Installation orientation and restrictions |
Installation orientation: • Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
| Terminal connection diagram |
![]() |
|||
| Input disconnection detection |
Not supported. | |||
Analog Input Unit (voltage input type) 8 points NX-AD4608
| Unit name | Analog Input Unit (voltage input type) |
Model | NX-AD4608 | |
|---|---|---|---|---|
| Number of points | 8 points | External connection terminals |
Screwless clamping terminal block (16 terminals) |
|
| I/O refreshing method | Selectable Synchronous I/O refreshing or Free-Run refreshing | |||
| Indicator | TS indicator![]() |
Input method | Differential Input | |
| Input range | -10 to +10 V | |||
| Input conversion range |
-5 to 105% (full scale) | |||
| Absolute maximum rating |
±15 V | |||
| Input impedance | 1 MΩ min. | |||
| Resolution | 1/30000 (full scale) | |||
| Overall accuracy |
25℃ | ±0.1% (full scale) | ||
| 0 to 55℃ | ±0.2% (full scale) | |||
| Conversion time | 10 μs/point | |||
| Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
| Insulation resistance | 20 MΩ min. between isolated circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. |
|
| I/O power supply method |
No supply | Current capacity of I/O power supply terminal |
Without I/O power supply terminals | |
| NX Unit power consumption |
• Connected to a CPU Unit or Communication Control Unit 1.45 W max. • Connected to a Communi- cations Coupler Unit 1.15 W max. |
I/O current consumption |
No consumption | |
| Weight | 70 g max. | |||
| Circuit layout | ![]() |
|||
| Installation orientation and restrictions |
Installation orientation: • • Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
| Terminal connection diagram |
![]() |
|||
| Input disconnection detection |
Not supported. | |||
Analog Input Unit (current input type) 2 points NX-AD2203
| Unit name | Analog Input Unit (current input type) |
Model | NX-AD2203 | |
|---|---|---|---|---|
| Number of points | 2 points | External connection terminals |
Screwless clamping terminal block (8 terminals) |
|
| I/O refreshing method | Free-Run refreshing | |||
| Indicator | TS indicator![]() |
Input method | Single-ended input | |
| Input range | 4 to 20 mA | |||
| Input conversion range |
-5 to 105% (full scale) | |||
| Absolute maximum rating |
±30 mA | |||
| Input impedance | 250 Ω min. | |||
| Resolution | 1/8000 (full scale) | |||
| Overall accuracy |
25℃ | ±0.2% (full scale) | ||
| 0 to 55℃ | ±0.4% (full scale) | |||
| Conversion time | 250 μs/point | |||
| Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
| Insulation resistance | 20 MΩ min. between isolated circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. |
|
| I/O power supply method |
Supply from the NX bus | Current capacity of I/O power supply terminal |
IOV: 0.1 A/terminal max., IOG: 0.1 A/terminal max. |
|
| NX Unit power consumption |
• Connected to a CPU Unit or Communication Control Unit 1.25 W max. • Connected to a Communi- cations Coupler Unit 0.90 W max. |
I/O current consumption |
No consumption | |
| Weight | 70 g max. | |||
| Circuit layout | ![]() |
|||
| Installation orientation and restrictions |
Installation orientation: • Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
| Terminal connection diagram |
![]() |
|||
| Input disconnection detection |
Supported. | |||
Analog Input Unit (current input type) 2 points NX-AD2204
| Unit name | Analog Input Unit (current input type) |
Model | NX-AD2204 | |
|---|---|---|---|---|
| Number of points | 2 points | External connection terminals |
Screwless clamping terminal block (8 terminals) |
|
| I/O refreshing method | Free-Run refreshing | |||
| Indicator | TS indicator![]() |
Input method | Differential Input | |
| Input range | 4 to 20 mA | |||
| Input conversion range |
-5 to 105% (full scale) | |||
| Absolute maximum rating |
±30 mA | |||
| Input impedance | 250 Ω min. | |||
| Resolution | 1/8000 (full scale) | |||
| Overall accuracy |
25℃ | ±0.2% (full scale) | ||
| 0 to 55℃ | ±0.4% (full scale) | |||
| Conversion time | 250 μs/point | |||
| Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
| Insulation resistance | 20 MΩ min. between isolated circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. |
|
| I/O power supply method |
No supply | Current capacity of I/O power supply terminal |
Without I/O power supply terminals | |
| NX Unit power consumption |
• Connected to a CPU Unit or Communication Control Unit 1.25 W max. • Connected to a Communi- cations Coupler Unit 0.90 W max. |
I/O current consumption |
No consumption | |
| Weight | 70 g max. | |||
| Circuit layout | ![]() |
|||
| Installation orientation and restrictions |
Installation orientation: • Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
| Terminal connection diagram |
![]() |
|||
| Input disconnection detection |
Supported. | |||
Analog Input Unit (current input type) 2 points NX-AD2208
| Unit name | Analog Input Unit (current input type) |
Model | NX-AD2208 | |
|---|---|---|---|---|
| Number of points | 2 points | External connection terminals |
Screwless clamping terminal block (8 terminals) |
|
| I/O refreshing method | Selectable Synchronous I/O refreshing or Free-Run refreshing | |||
| Indicator | TS indicator![]() |
Input method | Differential Input | |
| Input range | 4 to 20 mA | |||
| Input conversion range |
-5 to 105% (full scale) | |||
| Absolute maximum rating |
±30 mA | |||
| Input impedance | 250 Ω | |||
| Resolution | 1/30000 (full scale) | |||
| Overall accuracy |
25℃ | ±0.1% (full scale) | ||
| 0 to 55℃ | ±0.2% (full scale) | |||
| Conversion time | 10 μs/point | |||
| Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
| Insulation resistance | 20 MΩ min. between isolated circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. |
|
| I/O power supply method |
No supply | Current capacity of I/O power supply terminal |
Without I/O power supply terminals | |
| NX Unit power consumption |
• Connected to a CPU Unit or Communication Control Unit 1.25 W max. • Connected to a Communi- cations Coupler Unit 0.90 W max. |
I/O current consumption |
No consumption | |
| Weight | 70 g max. | |||
| Circuit layout | ![]() |
|||
| Installation orientation and restrictions |
Installation orientation: • Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
| Terminal connection diagram |
![]() |
|||
| Input disconnection detection |
Supported. | |||
Analog Input Unit (current input type) 4 points NX-AD3203
| Unit name | Analog Input Unit (current input type) |
Model | NX-AD3203 | |
|---|---|---|---|---|
| Number of points | 4 points | External connection terminals |
Screwless clamping terminal block (12 terminals) |
|
| I/O refreshing method | Free-Run refreshing | |||
| Indicator | TS indicator![]() |
Input method | Single-ended input | |
| Input range | 4 to 20 mA | |||
| Input conversion range |
-5 to 105% (full scale) | |||
| Absolute maximum rating |
±30 mA | |||
| Input impedance | 250 Ω min. | |||
| Resolution | 1/8000 (full scale) | |||
| Overall accuracy |
25℃ | ±0.2% (full scale) | ||
| 0 to 55℃ | ±0.4% (full scale) | |||
| Conversion time | 250 μs/point | |||
| Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
| Insulation resistance | 20 MΩ min. between isolated circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. |
|
| I/O power supply method |
Supply from the NX bus | Current capacity of I/O power supply terminal |
IOV: 0.1 A/terminal max., IOG: 0.1 A/terminal max. |
|
| NX Unit power consumption |
• Connected to a CPU Unit or Communication Control Unit 1.25 W max. • Connected to a Communi- cations Coupler Unit 0.90 W max. |
I/O current consumption |
No consumption | |
| Weight | 70 g max. | |||
| Circuit layout | ![]() |
|||
| Installation orientation and restrictions |
Installation orientation: • Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
| Terminal connection diagram |
![]() |
|||
| Input disconnection detection |
Supported. | |||
Analog Input Unit (current input type) 4 points NX-AD3204
| Unit name | Analog Input Unit (current input type) |
Model | NX-AD3204 | |
|---|---|---|---|---|
| Number of points | 4 points | External connection terminals |
Screwless clamping terminal block (12 terminals) |
|
| I/O refreshing method | Free-Run refreshing | |||
| Indicator | TS indicator![]() |
Input method | Differential Input | |
| Input range | 4 to 20 mA | |||
| Input conversion range |
-5 to 105% (full scale) | |||
| Absolute maximum rating |
±30 mA | |||
| Input impedance | 250 Ω min. | |||
| Resolution | 1/8000 (full scale) | |||
| Overall accuracy |
25℃ | ±0.2% (full scale) | ||
| 0 to 55℃ | ±0.4% (full scale) | |||
| Conversion time | 250 μs/point | |||
| Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
| Insulation resistance | 20 MΩ min. between isolated circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. |
|
| I/O power supply method |
No supply | Current capacity of I/O power supply terminal |
Without I/O power supply terminals | |
| NX Unit power consumption |
• Connected to a CPU Unit or Communication Control Unit 1.25 W max. • Connected to a Communi- cations Coupler Unit 0.90 W max. |
I/O current consumption |
No consumption | |
| Weight | 70 g max. | |||
| Circuit layout | ![]() |
|||
| Installation orientation and restrictions |
Installation orientation: • Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
| Terminal connection diagram |
![]() |
|||
| Input disconnection detection |
Supported. | |||
Analog Input Unit (current input type) 4 points NX-AD3208
| Unit name | Analog Input Unit (current input type) |
Model | NX-AD3208 | |
|---|---|---|---|---|
| Number of points | 4 points | External connection terminals |
Screwless clamping terminal block (12 terminals) |
|
| I/O refreshing method | Selectable Synchronous I/O refreshing or Free-Run refreshing | |||
| Indicator | TS indicator![]() |
Input method | Differential Input | |
| Input range | 4 to 20 mA | |||
| Input conversion range |
-5 to 105% (full scale) | |||
| Absolute maximum rating |
±30 mA | |||
| Input impedance | 250 Ω min. | |||
| Resolution | 1/30000 (full scale) | |||
| Overall accuracy |
25℃ | ±0.1% (full scale) | ||
| 0 to 55℃ | ±0.2% (full scale) | |||
| Conversion time | 10 μs/point | |||
| Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
| Insulation resistance | 20 MΩ min. between isolated circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. |
|
| I/O power supply method |
No supply | Current capacity of I/O power supply terminal |
Without I/O power supply terminals | |
| NX Unit power consumption |
• Connected to a CPU Unit or Communication Control Unit 1.30 W max. • Connected to a Communi- cations Coupler Unit 0.95 W max. |
I/O current consumption |
No consumption | |
| Weight | 70 g max. | |||
| Circuit layout | ![]() |
|||
| Installation orientation and restrictions |
Installation orientation: • Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
| Terminal connection diagram |
![]() |
|||
| Input disconnection detection |
Supported. | |||
Analog Input Unit (current input type) 8 points NX-AD4203
| Unit name | Analog Input Unit (current input type) |
Model | NX-AD4203 | |
|---|---|---|---|---|
| Number of points | 8 points | External connection terminals |
Screwless clamping terminal block (16 terminals) |
|
| I/O refreshing method | Free-Run refreshing | |||
| Indicator | TS indicator![]() |
Input method | Single-ended input | |
| Input range | 4 to 20 mA | |||
| Input conversion range |
-5 to 105% (full scale) | |||
| Absolute maximum rating |
±30 mA | |||
| Input impedance | 85 Ω | |||
| Resolution | 1/8000 (full scale) | |||
| Overall accuracy |
25℃ | ±0.2% (full scale) | ||
| 0 to 55℃ | ±0.4% (full scale) | |||
| Conversion time | 250 μs/point | |||
| Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
| Insulation resistance | 20 MΩ min. between isolated circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. |
|
| I/O power supply method |
Supply from the NX bus | Current capacity of I/O power supply terminal |
IOV: 0.1 A/terminal max. | |
| NX Unit power consumption |
• Connected to a CPU Unit or Communication Control Unit 1.40 W max. • Connected to a Communi- cations Coupler Unit 1.05 W max. |
I/O current consumption |
No consumption | |
| Weight | 70 g max. | |||
| Circuit layout | ![]() |
|||
| Installation orientation and restrictions |
Installation orientation: • Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
| Terminal connection diagram |
![]() |
|||
| Input disconnection detection |
Supported. | |||
Analog Input Unit (current input type) 8 points NX-AD4204
| Unit name | Analog Input Unit (current input type) |
Model | NX-AD4204 | |
|---|---|---|---|---|
| Number of points | 8 points | External connection terminals |
Screwless clamping terminal block (16 terminals) |
|
| I/O refreshing method | Free-Run refreshing | |||
| Indicator | TS indicator![]() |
Input method | Differential Input | |
| Input range | 4 to 20 mA | |||
| Input conversion range |
-5 to 105% (full scale) | |||
| Absolute maximum rating |
±30 mA | |||
| Input impedance | 85 Ω | |||
| Resolution | 1/8000 (full scale) | |||
| Overall accuracy |
25℃ | ±0.2% (full scale) | ||
| 0 to 55℃ | ±0.4% (full scale) | |||
| Conversion time | 250 μs/point | |||
| Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
| Insulation resistance | 20 MΩ min. between isolated circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. |
|
| I/O power supply method |
No supply | Current capacity of I/O power supply terminal |
Without I/O power supply terminals | |
| NX Unit power consumption |
• Connected to a CPU Unit or Communication Control Unit 1.40 W max. • Connected to a Communi- cations Coupler Unit 1.05 W max. |
I/O current consumption |
No consumption | |
| Weight | 70 g max. | |||
| Circuit layout | ![]() |
|||
| Installation orientation and restrictions |
Installation orientation: • Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
| Terminal connection diagram |
![]() |
|||
| Input disconnection detection |
Supported. | |||
Analog Input Unit (current input type) 8 points NX-AD4208
| Unit name | Analog Input Unit (current input type) |
Model | NX-AD4208 | |
|---|---|---|---|---|
| Number of points | 8 points | External connection terminals |
Screwless clamping terminal block (16 terminals) |
|
| I/O refreshing method | Selectable Synchronous I/O refreshing or Free-Run refreshing | |||
| Indicator | TS indicator![]() |
Input method | Differential Input | |
| Input range | 4 to 20 mA | |||
| Input conversion range |
-5 to 105% (full scale) | |||
| Absolute maximum rating |
±30 mA | |||
| Input impedance | 85 Ω | |||
| Resolution | 1/30000 (full scale) | |||
| Overall accuracy |
25℃ | ±0.1% (full scale) | ||
| 0 to 55℃ | ±0.2% (full scale) | |||
| Conversion time | 10 μs/point | |||
| Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
| Insulation resistance | 20 MΩ min. between isolated circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. |
|
| I/O power supply method |
No supply | Current capacity of I/O power supply terminal |
Without I/O power supply terminals | |
| NX Unit power consumption |
• Connected to a CPU Unit or Communication Control Unit 1.45 W max. • Connected to a Communi- cations Coupler Unit 1.10 W max. |
I/O current consumption |
No consumption | |
| Weight | 70 g max. | |||
| Circuit layout | ![]() |
|||
| Installation orientation and restrictions |
Installation orientation: • Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
| Terminal connection diagram |
![]() |
|||
| Input disconnection detection |
Supported. | |||
Analog Output Unit Specifications
Analog Output Unit (voltage output type) 2 points NX-DA2603
| Unit name | Analog Output Unit (voltage output type) |
Model | NX-DA2603 | |
|---|---|---|---|---|
| Number of points | 2 points | External connection terminals |
Screwless clamping terminal block (8 terminals) |
|
| I/O refreshing method | Free-Run refreshing | |||
| Indicator | TS indicator![]() |
Output range | -10 to +10 V | |
| Output conversion range |
-5 to 105% (full scale) | |||
| Allowable load resistance |
5 kΩ min. | |||
| Output impedance | 0.5 Ω max. | |||
| Resolution | 1/8000 (full scale) | |||
| Overall accuracy |
25℃ | ±0.3% (full scale) | ||
| 0 to 55℃ | ±0.5% (full scale) | |||
| Conversion time | 250 μs/point | |||
| Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
| Insulation resistance | 20 MΩ min. between isolated circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. |
|
| I/O power supply method |
Supply from the NX bus | Current capacity of I/O power supply terminal |
IOV: 0.1 A/terminal max., IOG: 0.1 A/terminal max. |
|
| NX Unit power consumption |
• Connected to a CPU Unit or Communication Control Unit 1.40 W max. • Connected to a Communi- cations Coupler Unit 1.10 W max. |
I/O current consumption |
No consumption | |
| Weight | 70 g max. | |||
| Circuit layout | ![]() |
|||
| Installation orientation and restrictions |
Installation orientation: • Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
| Terminal connection diagram |
![]() |
|||
Analog Output Unit (voltage output type) 2 points NX-DA2605
| Unit name | Analog Output Unit (voltage output type) |
Model | NX-DA2605 | |
|---|---|---|---|---|
| Number of points | 2 points | External connection terminals |
Screwless clamping terminal block (8 terminals) |
|
| I/O refreshing method | Selectable Synchronous I/O refreshing or Free-Run refreshing | |||
| Indicator | TS indicator![]() |
Output range | -10 to +10 V | |
| Output conversion range |
-5 to 105% (full scale) | |||
| Allowable load resistance |
5 kΩ min. | |||
| Output impedance | 0.5 Ω max. | |||
| Resolution | 1/30000 (full scale) | |||
| Overall accuracy |
25℃ | ±0.1% (full scale) | ||
| 0 to 55℃ | ±0.3% (full scale) | |||
| Conversion time | 10 μs/point | |||
| Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
| Insulation resistance | 20 MΩ min. between isolated circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. |
|
| I/O power supply method |
Supply from the NX bus | Current capacity of I/O power supply terminal |
IOV: 0.1 A/terminal max., IOG: 0.1 A/terminal max. |
|
| NX Unit power consumption |
• Connected to a CPU Unit or Communication Control Unit 1.40 W max. • Connected to a Communi- cations Coupler Unit 1.10 W max. |
I/O current consumption |
No consumption | |
| Weight | 70 g max. | |||
| Circuit layout | ![]() |
|||
| Installation orientation and restrictions |
Installation orientation: • Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
| Terminal connection diagram |
![]() |
|||
Analog Output Unit (voltage output type) 4 points NX-DA3603
| Unit name | Analog Output Unit (voltage output type) |
Model | NX-DA3603 | |
|---|---|---|---|---|
| Number of points | 4 points | External connection terminals |
Screwless clamping terminal block (12 terminals) |
|
| I/O refreshing method | Free-Run refreshing | |||
| Indicator | TS indicator![]() |
Output range | -10 to +10 V | |
| Output conversion range |
-5 to 105% (full scale) | |||
| Allowable load resistance |
5 kΩ min. | |||
| Output impedance | 0.5 Ω max. | |||
| Resolution | 1/8000 (full scale) | |||
| Overall accuracy |
25℃ | ±0.3% (full scale) | ||
| 0 to 55℃ | ±0.5% (full scale) | |||
| Conversion time | 250 μs/point | |||
| Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
| Insulation resistance | 20 MΩ min. between isolated circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. |
|
| I/O power supply method |
Supply from the NX bus | Current capacity of I/O power supply terminal |
IOV: 0.1 A/terminal max., IOG: 0.1 A/terminal max. |
|
| NX Unit power consumption |
• Connected to a CPU Unit or Communication Control Unit 1.35 W max. • Connected to a Communi- cations Coupler Unit 1.25 W max. |
I/O current consumption |
No consumption | |
| Weight | 70 g max. | |||
| Circuit layout | ![]() |
|||
| Installation orientation and restrictions |
Installation orientation: • Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
| Terminal connection diagram |
![]() |
|||
Analog Output Unit (voltage output type) 4 points NX-DA3605
| Unit name | Analog Output Unit (voltage output type) |
Model | NX-DA3605 | |
|---|---|---|---|---|
| Number of points | 4 points | External connection terminals |
Screwless clamping terminal block (12 terminals) |
|
| I/O refreshing method | Selectable Synchronous I/O refreshing or Free-Run refreshing | |||
| Indicator | TS indicator![]() |
Output range | -10 to +10 V | |
| Output conversion range |
-5 to 105% (full scale) | |||
| Allowable load resistance |
5 kΩ min. | |||
| Output impedance | 0.5 Ω max. | |||
| Resolution | 1/30000 (full scale) | |||
| Overall accuracy |
25℃ | ±0.1% (full scale) | ||
| 0 to 55℃ | ±0.3% (full scale) | |||
| Conversion time | 10 μs/point | |||
| Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
| Insulation resistance | 20 MΩ min. between isolated circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. |
|
| I/O power supply method |
Supply from the NX bus | Current capacity of I/O power supply terminal |
IOV: 0.1 A/terminal max., IOG: 0.1 A/terminal max. |
|
| NX Unit power consumption |
• Connected to a CPU Unit or Communication Control Unit 1.60 W max. • Connected to a Communi- cations Coupler Unit 1.25 W max. |
I/O current consumption |
No consumption | |
| Weight | 70 g max. | |||
| Circuit layout | ![]() |
|||
| Installation orientation and restrictions |
Installation orientation: • Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: No restrictions |
|||
| Terminal connection diagram |
![]() |
|||
Analog Output Unit (current output type) 2 points NX-DA2203
| Unit name | Analog Output Unit (current output type) |
Model | NX-DA2203 | |
|---|---|---|---|---|
| Number of points | 2 points | External connection terminals |
Screwless clamping terminal block (8 terminals) |
|
| I/O refreshing method | Free-Run refreshing | |||
| Indicator | TS indicator![]() |
Output range | 4 to 20 mA | |
| Output conversion range |
-5 to 105% (full scale) | |||
| Allowable load resistance |
600 Ω min. | |||
| Resolution | 1/8000 (full scale) | |||
| Overall accuracy |
25℃ | ±0.3% (full scale) | ||
| 0 to 55℃ | ±0.6% (full scale) | |||
| Conversion time | 250 μs/point | |||
| Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
| Insulation resistance | 20 MΩ min. between isolated circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. |
|
| I/O power supply method |
Supply from the NX bus | Current capacity of I/O power supply terminal |
IOV: 0.1 A/terminal max., IOG: 0.1 A/terminal max. |
|
| NX Unit power consumption |
• Connected to a CPU Unit or Communication Control Unit 2.10 W max. • Connected to a Communi- cations Coupler Unit 1.75 W max. |
I/O current consumption |
No consumption | |
| Weight | 70 g max. | |||
| Circuit layout | ![]() |
|||
| Installation orientation and restrictions |
Installation orientation: • Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: For upright installation: No restrictions For any installation other than upright: Restricted as shown in the graph below. ![]() |
|||
| Terminal connection diagram |
![]() |
|||
Analog Output Unit (current output type) 2 points NX-DA2205
| Unit name | Analog Output Unit (current output type) |
Model | NX-DA2205 | |
|---|---|---|---|---|
| Number of points | 2 points | External connection terminals |
Screwless clamping terminal block (8 terminals) |
|
| I/O refreshing method | Selectable Synchronous I/O refreshing or Free-Run refreshing | |||
| Indicator | TS indicator![]() |
Output range | 4 to 20 mA | |
| Output conversion range |
-5 to 105% (full scale) | |||
| Allowable load resistance |
600 Ω min. | |||
| Resolution | 1/30000 (full scale) | |||
| Overall accuracy |
25℃ | ±0.1% (full scale) | ||
| 0 to 55℃ | ±0.3% (full scale) | |||
| Conversion time | 10 μs/point | |||
| Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
| Insulation resistance | 20 MΩ min. between isolated circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. |
|
| I/O power supply method |
Supply from the NX bus | Current capacity of I/O power supply terminal |
IOV: 0.1 A/terminal max., IOG: 0.1 A/terminal max. |
|
| NX Unit power consumption |
• Connected to a CPU Unit or Communication Control Unit 2.10 W max. • Connected to a Communi- cations Coupler Unit 1.75 W max. |
I/O current consumption |
No consumption | |
| Weight | 70 g max. | |||
| Circuit layout | ![]() |
|||
| Installation orientation and restrictions |
Installation orientation: • Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: For upright installation: No restrictions For any installation other than upright: Restricted as shown in the graph below. ![]() |
|||
| Terminal connection diagram |
![]() |
|||
Analog Output Unit (current output type) 4 points NX-DA3203
| Unit name | Analog Output Unit (current output type) |
Model | NX-DA3203 | |
|---|---|---|---|---|
| Number of points | 4 points | External connection terminals |
Screwless clamping terminal block (12 terminals) |
|
| I/O refreshing method | Free-Run refreshing | |||
| Indicator | TS indicator![]() |
Output range | 4 to 20 mA | |
| Output conversion range |
-5 to 105% (full scale) | |||
| Allowable load resistance |
350 Ω min. | |||
| Resolution | 1/8000 (full scale) | |||
| Overall accuracy |
25℃ | ±0.3% (full scale) | ||
| 0 to 55℃ | ±0.6% (full scale) | |||
| Conversion time | 250 μs/point | |||
| Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
| Insulation resistance | 20 MΩ min. between isolated circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. |
|
| I/O power supply method |
Supply from the NX bus | Current capacity of I/O power supply terminal |
IOV: 0.1 A/terminal max., IOG: 0.1 A/terminal max. |
|
| NX Unit power consumption |
• Connected to a CPU Unit or Communication Control Unit 2.10 W max. • Connected to a Communi- cations Coupler Unit 1.80 W max. |
I/O current consumption |
No consumption | |
| Weight | 70 g max. | |||
| Circuit layout | ![]() |
|||
| Installation orientation and restrictions |
Installation orientation: • Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: For upright installation: No restrictions For any installation other than upright: Restricted as shown in the graph below. ![]() |
|||
| Terminal connection diagram |
![]() |
|||
Analog Output Unit (current output type) 4 points NX-DA3205
| Unit name | Analog Output Unit (current output type) |
Model | NX-DA3205 | |
|---|---|---|---|---|
| Number of points | 4 points | External connection terminals |
Screwless clamping terminal block (12 terminals) |
|
| I/O refreshing method | Free-Run refreshing | |||
| Indicator | TS indicator![]() |
Output range | 4 to 20 mA | |
| Output conversion range |
-5 to 105% (full scale) | |||
| Allowable load resistance |
350 Ω min. | |||
| Resolution | 1/30000 (full scale) | |||
| Overall accuracy |
25℃ | ±0.1% (full scale) | ||
| 0 to 55℃ | ±0.3% (full scale) | |||
| Conversion time | 10 μs/point | |||
| Dimensions | 12 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus: Power = Transformer, Signal = Digital isolator (no isolation between inputs) |
|
| Insulation resistance | 20 MΩ min. between isolated circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. |
|
| I/O power supply method |
Supply from the NX bus | Current capacity of I/O power supply terminal |
IOV: 0.1 A/terminal max., IOG: 0.1 A/terminal max. |
|
| NX Unit power consumption |
• Connected to a CPU Unit or Communication Control Unit 2.10 W max. • Connected to a Communi- cations Coupler Unit 1.80 W max. |
I/O current consumption |
No consumption | |
| Weight | 70 g max. | |||
| Circuit layout | ![]() |
|||
| Installation orientation and restrictions |
Installation orientation: • Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: For upright installation: No restrictions For any installation other than upright: Restricted as shown in the graph below. ![]() |
|||
| Terminal connection diagram |
![]() |
|||
Version Information
Connected to a CPU Unit
Refer to the user’s manual for the CPU Unit details on the CPU Units to which NX Units can be connected.
| NX Units | Corresponding unit versions/versions | ||
|---|---|---|---|
| Model | Unit version | CPU Unit | Sysmac Studio |
| NX-AD[][][][] NX-DA[][][][] |
Ver.1.0 | Ver.1.13 | Ver.1.17 |
support is provided by the oldest available version after the specified version. Refer to the user’s manuals for the
specific Units for the relation between models and versions.
Connected to an EtherCAT Coupler Unit
| NX Units | Corresponding unit versions/versions | |||
|---|---|---|---|---|
| Model | Unit version | EtherCAT Coupler Unit | CPU Unit or Industrial PC | Sysmac Studio |
| NX-AD[][][][] NX-DA[][][][] |
Ver.1.0 | Ver.1.0 | Ver.1.05 | Ver.1.06 |
support is provided by the oldest available version after the specified version. Refer to the user’s manuals for the
specific Units for the relation between models and versions.
Connected to an EtherNet/IP Coupler Unit
| NX Units | Corresponding unit versions/versions | ||||||
|---|---|---|---|---|---|---|---|
| Model | Unit version |
Application with an NJ/NX/NY-series Controller *1 |
Application with a CS/CJ/CP-series PLC *2 |
||||
| EtherNet/IP Coupler Unit |
CPU Unit or Industrial PC |
Sysmac Studio |
EtherNet/IP Coupler Unit |
Sysmac Studio |
NX-IO Configurator *3 |
||
| NX-AD[][][][] NX-DA[][][][] |
Ver.1.0 | Ver. 1.2 | Ver. 1.14 | Ver. 1.19 | Ver. 1.0 | Ver. 1.10 | Ver. 1.00 |
support is provided by the oldest available version after the specified version. Refer to the user’s manuals for the
specific Units for the relation between models and versions.
*1 Refer to the user’s manual for the EtherNet/IP Coupler Units for information on the unit versions of EtherNet/IP Units
that are compatible with EtherNet/IP Coupler Units.
*2 Refer to the user’s manual for the EtherNet/IP Coupler Units for information on the unit versions of CPU Units and
EtherNet/IP Units that are compatible with EtherNet/IP Coupler Units.
*3 For connection to an EtherNet/IP Coupler Unit with unit version 1.0, connection is supported only for a connection to the
peripheral USB port on the EtherNet/IP Coupler Unit. You cannot connect by any other path. If you need to connect by
another path, use an EtherNet/IP Coupler Unit with unit version 1.2 or later.
Connected to Communication Control Units
| NX Units | Corresponding unit versions/versions | ||
|---|---|---|---|
| Model | Unit version | Communication Control Unit | Sysmac Studio |
| NX-AD[][][][] NX-DA[][][][] |
Ver.1.0 | Ver.1.00 | Ver.1.24 |
support is provided by the oldest available version after the specified version. Refer to the user’s manuals for the
specific Units for the relation between models and versions.
(Unit: mm)
Screwless Clamping Terminal Block Type
12 mm Width

* The dimension is 1.35 mm for Units with lot numbers through December 2014.
|
Catalog Name
|
Catalog Number
[size] |
Last Update
|
|---|---|---|
| – [5946KB] |
Aug 01, 2018 | |
| R183-E1-09 [6683KB] |
Nov 01, 2018 |